Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 11 of 11 for “"High-frequency isolation"”.

  1. A Single Stage High-Frequency Rectifier for EV Charging Applications

    … single-stage three-phase rectifier topology with high-frequency isolation for EV (Electric Vehicle) fast-charging stations is proposed. By using a multipulse approach, low-order harmonics in the input current are shown to be eliminated over a wide range. A SST (Solid State Transformer) is used to …

    tamu Repository record for A Single Stage High-Frequency Rectifier for EV Charging Applications (opens in a new tab)

  2. Soft-switching solid state transformer (S4T)

    … to another single or multi-phase AC or DC with high-frequency isolation between the input and the output. It provides features of bidirectional power flow control, reactive power compensation, harmonics suppression, voltage regulation, sag correction, and fault isolation. Conventional topologies …

    gatech Repository record for Soft-switching solid state transformer (S4T) (opens in a new tab)

  3. State Space Modelling of Current-Mode Control and its Application to Input Impedance Shaping of Power Electronic Constant-Power Loads

    … conversion efficiency and reduced mass due to high-frequency isolation. Unfortunately, distributed DC systems with regulated bus voltages suffer from destabilising effects from loading by downstream power electronic converters behaving as constant-power loads. Power electronic constant-power …

    concordia Download PDF for State Space Modelling of Current-Mode Control and its Application to Input Impedance Shaping of Power Electronic Constant-Power Loads (opens in a new tab)

  4. Development of a High-Frequency Isolated, Power Factor Corrected Converter

    … used to convert the shore supply voltage and frequency to that required by the vessel. Commonly in industry, isolation is provided by a mains frequency transformer. Therefore, the converter size and weight are significant. Within a marine environment, this is very disadvantageous. However, …

    auckland-tech Repository record for Development of a High-Frequency Isolated, Power Factor Corrected Converter (opens in a new tab)

  5. Bi-directional DC-DC converter for low power applications

    … current fed push-pull on the secondary side of a high frequency isolation transformer. The small signal and steady state analyses of the proposed topology are presented. Characteristic curves generated from the analysis aid the design of a laboratory prototype as demonstrated by a detailed design …

    concordia Download PDF for Bi-directional DC-DC converter for low power applications (opens in a new tab)

  6. Three-Phase Single-Stage Isolated AC–DC Converters for Electric Vehicle Battery Charging

    … Both converters integrate input-current shaping, high-frequency isolation, and constant-current/constant-voltage (CC/CV) output regulation within a single power-conversion stage. The first topology is a three-phase single-stage soft-switching converter comprising a three-phase bridge, grid-side …

    queens Repository record for Three-Phase Single-Stage Isolated AC–DC Converters for Electric Vehicle Battery Charging (opens in a new tab)

  7. Low-Voltage Soft-Switching Solid-State Transformer (S4T) Enabled by the Synchronous Reverse Blocking Switch

    … objective of this research is to demonstrate a high-efficiency, low-voltage Soft-Switching Solid-State Transformer (S4T) enabled by the Synchronous Reverse Blocking (RB) Switch, a patent-pending method to seamlessly integrate dual-active-switch structures into the S4T topology to minimize …

    gatech Repository record for Low-Voltage Soft-Switching Solid-State Transformer (S4T) Enabled by the Synchronous Reverse Blocking Switch (opens in a new tab)

  8. Applications of an electronic transformer in a power distribution system

    … which performs many functions. At its operating frequency (60/50 Hz), it is one of the most bulky and expensive components. The concept of the electronic transformer introduced previously has shown considerable reduction in size, weight, and volume by operating at a higher frequency. In this …

    tamu Repository record for Applications of an electronic transformer in a power distribution system (opens in a new tab)

  9. Direct velocity feedback control of equipment vibration

    … existing passive mounts is to attenuate the low frequency amplification effect generated by the passive isolation system. Passive damping can be added in the mounts to limit this adverse effect but this decreases the high frequency performance provided by the passive isolation. In a previous …

    soton Download PDF for Direct velocity feedback control of equipment vibration (opens in a new tab)

  10. Analysis and Design of New Three-Phase AC-DC Rectifier Systems with Higher Frequency Isolation

    … three-phase AC-DC conversion is employed in many high power applications that require integration with the utility grid such as electric vehicle charging, adjustable speed drive systems, telecommunication power supplies, and renewable energy systems. The power electronics industry is constantly …

    tamu Repository record for Analysis and Design of New Three-Phase AC-DC Rectifier Systems with Higher Frequency Isolation (opens in a new tab)

  11. High Frequency Isolated Single-Stage Integrated Resonant AC-DC Converters for PMSG Based Wind Energy Conversion Systems

    In this dissertation, two high-frequency (HF) transformer isolated single-stage integrated ac-dc converters are proposed for a small scale permanent magnet synchronous generator (PMSG) based wind energy conversion system (WECS). These two types of single-stage integrated ac-dc converters include …

    uvic Repository record for High Frequency Isolated Single-Stage Integrated Resonant AC-DC Converters for PMSG Based Wind Energy Conversion Systems (opens in a new tab)