Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 8 of 8 for “"Highly cross- linked polyethylene"”

  1. Wear of Highly Cross-Linked Polyethylene in Primary Total Hip Replacement

    … component. Acetabular components utilizing highly cross-linked polyethylene (XLPE) have been shown to wear less than earlier conventional polyethylene. Reported in vivo XLPE wear rates vary due to differing radiographic measurement techniques and methods of reporting results. XLPE liners are …

    adelaide Repository record for Wear of Highly Cross-Linked Polyethylene in Primary Total Hip Replacement (opens in a new tab)

  2. Mechanical Properties of Retrieved Highly Cross-linked Polyethylene Acetabular Liners in Total Hip Arthroplasty

    Highly cross-linked polyethylene (HXLPE) has replaced the conventional ultra-high-molecular-weight-polyethylene (UHMWPE) as the gold standard bearing surface in total hip arthroplasty (THA) due to superior wear characteristics and survivorship. However, HXLPE has demonstrated poorer mechanical …

    uwo Repository record for Mechanical Properties of Retrieved Highly Cross-linked Polyethylene Acetabular Liners in Total Hip Arthroplasty (opens in a new tab)

  3. The Impact of Free Radical Stabilization Techniques on In Vivo Property Changes in Highly Cross-Linked Polyethylene Acetabular Liners

    Highly cross-linked polyethylene (HXLPE) was introduced into total hip arthroplasty (THA) to reduce long-term wear-related complications. However, HXLPE production and in vivo oxidation can alter mechanical behavior. Mechanical failure of HXLPE liners at the implant rim have been reported. The …

    uwo Repository record for The Impact of Free Radical Stabilization Techniques on In Vivo Property Changes in Highly Cross-Linked Polyethylene Acetabular Liners (opens in a new tab)

  4. A comparison of wear of 36 mm and 28 mm metal-on-highly cross-linked polyethylene articulations in primary total hip replacements

    … incidence of dislocation and low wear. Metal-on-highly cross-linked polyethylene (HXLPE) articulations of 36 mm diameter have been demonstrated in a randomised controlled trial to have a significantly lower incidence of dislocation at one year postoperatively compared to 28 mm articulations. …

    adelaide Repository record for A comparison of wear of 36 mm and 28 mm metal-on-highly cross-linked polyethylene articulations in primary total hip replacements (opens in a new tab)

  5. Wear and migration in total hip arthroplasty measured with Radiostereometric Analysis. Methodological aspects and clinical studies

    … Stereophotogrammetric Analysis (RSA) is a highly accurate technique that enables three-dimensional measurements of skeletal or implant micromovement with respect to the host bone in vivo. The method has been used in clinical research for the evaluation of penetration of the femoral head …

    goteborg Repository record for Wear and migration in total hip arthroplasty measured with Radiostereometric Analysis. Methodological aspects and clinical studies (opens in a new tab)

  6. Improvements in hip arthroplasty - did they work? Evaluations of different articulations and fixation concepts.

    … Papers II and III contain comparisons of highly cross-linked polyethylene (XLPE) and conventional polyethylene (PE). XLPE had a considerably lower wear rate up to 10 years but showed no obvious improvements regarding implant fixation, BMD or clinical outcome. In the NARA registry, in 2 of …

    goteborg Repository record for Improvements in hip arthroplasty - did they work? Evaluations of different articulations and fixation concepts. (opens in a new tab)

  7. The role of head size in total hip arthroplasty - Dislocation, wear and cup stability

    … dislocation, but there are concerns related to polyethylene wear, corrosion and cup loosening. Paper I is an observational study that aimed to investigate whether the transition from 28-mm to 32-mm heads and thereafter to 36-mm heads in patients undergoing total hip arthroplasty (THA) after …

    goteborg Repository record for The role of head size in total hip arthroplasty - Dislocation, wear and cup stability (opens in a new tab)

  8. New polymer materials in total hip arthroplasty. Evaluation with radiostereometry, bone densitometry, radiography and clinical parameters

    … To evaluate the outcome of different types of polyethylene, bone cements and one design of uncemented fixation with porous and ceramic coating using radiostereometry, bone densitometry, conventional radiography and clinical parameters.Materials and methods: Study 1: 201 patients were extracted …

    goteborg Repository record for New polymer materials in total hip arthroplasty. Evaluation with radiostereometry, bone densitometry, radiography and clinical parameters (opens in a new tab)