Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 24 for “"Hip simulator"”

  1. Surface characterization of metal-metal hip implants tested in a hip simulator

    … six of the implants were examined prior to simulator testing, three after 3 million cycles of testing at 3 times body weight, and six after 6 million cycles of testing, also at 3 times body weight. In the second part of the study, the six implants that were examined prior to testing in the …

    mcgill Repository record for Surface characterization of metal-metal hip implants tested in a hip simulator (opens in a new tab)

  2. The corrosion of CoCrMo alloys for biomedical applications

    … are now frequently used for the metal-on-metal hip resurfacing joints due to their high corrosion and wear performance. The present project was carried out to investigate the feasibility of taking electrochemical measurements from hip resurfacing joints whilst articulating in a hip simulator. In …

    birmingham Repository record for The corrosion of CoCrMo alloys for biomedical applications (opens in a new tab)

  3. Wear and rim damage of UHMWPE acetabular cups in total hip replacement

    … reported to play a role in the failure of total hip replacements. Edge loading of hip replacements can occur where there is sub-optimal component positioning and/or joint laxity. Wear resistance can be improved by crosslinking but the manufacturing process of these materials involves …

    whiterose Repository record for Wear and rim damage of UHMWPE acetabular cups in total hip replacement (opens in a new tab)

  4. Modelling different mechanical damage mechanisms of ultra-high molecular weight polyethylene liners in total hip replacements

    Over 1 million total hip replacements (THRs) are performed around the world every year. Advances in the polyethylene liner materials have improved the wear resistance and longevity of well-functioning THRs. However, THRs with malpositioned components and unbalanced tissue forces can generate …

    whiterose Repository record for Modelling different mechanical damage mechanisms of ultra-high molecular weight polyethylene liners in total hip replacements (opens in a new tab)

  5. Torques in total hip replacements

    … torques at the articulating interface of total hip replacements (THRs), if transferred, have the potential to affect component fixation and/or induce micro motion linked to fretting and corrosion at modular junctions. Pre-clinical testing of friction behaviour in THRs has predominantly been …

    whiterose Repository record for Torques in total hip replacements (opens in a new tab)

  6. Impingement in total hip replacements

    … most common reason for early failure in total hip replacements (THRs) and occurs following impingement. Impingement is the unwanted contact between either the component and/or bone around the THR. This thesis investigates the effect of factors such as patient bony anatomy, patient activity and …

    whiterose Repository record for Impingement in total hip replacements (opens in a new tab)

  7. Characterisation and Biological Impact of Wear Particles from Composite Ceramic Hip Replacements

    … of conventional metal-on-UHMWPE (MoP) total hip replacements (THRs), and concerns over the release of metal wear particles and metal ions around the body from metal-on-metal (MoM) THRs, led to the development of alternative ceramic-on-ceramic (CoC) THRs. CoC bearings are of great interest due …

    whiterose Repository record for Characterisation and Biological Impact of Wear Particles from Composite Ceramic Hip Replacements (opens in a new tab)

  8. In Vitro Investigation into the use of Dual Mobility for Partial Revision of a Failed Metal Hip Resurfacing

    … is to investigate whether a failed MOM total hip resurfacing arthroplasty (THRA) can be converted to a successful total hip arthroplasty (THA) during partial revision surgery using an alternative bearing surface for the femoral bearing surface only. It is estimated that around 10% of primary …

    durham Repository record for In Vitro Investigation into the use of Dual Mobility for Partial Revision of a Failed Metal Hip Resurfacing (opens in a new tab)

  9. Tribocorrosion of total hip replacements

    The performance of metal-on-metal total hip replacements is largely determined by their propensity to degrade in vivo. Degradation occurs through the complex interactions between wear and corrosion (termed tribocorrosion) and leads to the production of metallic particulate debris and metallic ions. …

    whiterose Repository record for Tribocorrosion of total hip replacements (opens in a new tab)

  10. Wear and lubrication of metal-metal bearings for total hip arthroplasty

    A major current concern in total hip arthroplasty is the generation of polyethylene wear particles at the articulating surfaces and resulting macrophage-mediated, periimplant osteolysis. There has been revived interest in metal-metal bearings for hip implants because of their potential for improved …

    mcgill Repository record for Wear and lubrication of metal-metal bearings for total hip arthroplasty (opens in a new tab)

  11. Understanding Movement and its Influence on Tribology of the Human Hip

    Total hip arthroplasty is one of the most successful and innovative medical procedures developed during the 20th century. Success post-op has been shown to decrease for younger, more active patients when compared to those who are older and less active, raising concerns surrounding the reasons …

    whiterose Repository record for Understanding Movement and its Influence on Tribology of the Human Hip (opens in a new tab)

  12. APPLICATIONS IN VIBROARTHROGRAPHY: ASSESSMENTS OF INSTABILITY IN TOTAL HIP ARTHROPLASTY, CAM-POST ENGAGEMENT IN TOTAL KNEE ARTHROPLASTY, AND VISCOSUPPLEMENTATION IN OSTEOARTHRITIC KNEES

    … These areas include 1) instability in total hip arthroplasty, 2) cam-post engagement in posterior stabilized total knee arthroplasty, and 3) viscosupplementation in osteoarthritic knees. It was expected that each of these unique cases would be characterized by dynamic phenomena that could be …

    utk-theses Repository record for APPLICATIONS IN VIBROARTHROGRAPHY: ASSESSMENTS OF INSTABILITY IN TOTAL HIP ARTHROPLASTY, CAM-POST ENGAGEMENT IN TOTAL KNEE ARTHROPLASTY, AND VISCOSUPPLEMENTATION IN OSTEOARTHRITIC KNEES (opens in a new tab)

  13. Tribology of prosthetic joints : validation of wear simulation methods

    In hip and knee arthroplasty, loosening of prosthetic components is the principal reason for expensive and complicated reoperations. Loosening is believed to be caused mainly by tissue reactions to wear particles removed from ultrahigh molecular weight polyethylene bearing surfaces. The tissue …

    aalto Repository record for Tribology of prosthetic joints : validation of wear simulation methods (opens in a new tab)

  14. Development and Implementation of a Computational Surgical Planning Model for Pre-Operative Planning and Post-Operative Assessment and Analysis of Total Hip Arthroplasty

    <p>Total hip arthroplasty (THA) is most often used to treat osteoarthritis of the hip joint. Due to lack of a better alternative, newer designs are evaluated experimentally using mechanical simulators and cadavers. These evaluation techniques, though necessary, are costly and time-consuming, …

    utk-theses Repository record for Development and Implementation of a Computational Surgical Planning Model for Pre-Operative Planning and Post-Operative Assessment and Analysis of Total Hip Arthroplasty (opens in a new tab)

  15. Hip Replacement Head-Neck Taper Connection Tribocorrosion Reduction by Head Material, Head Size and Taper Geometric Optimization

    Modular femoral head hip replacement components connect to the femoral stem via matching tapers. Metals commonly used to manufacture femoral heads and stems rely on a passive oxide layer to resist corrosion. Under cyclic loading (i.e. gait) relative micromotion between the head and stem causes …

    toronto-retro Repository record for Hip Replacement Head-Neck Taper Connection Tribocorrosion Reduction by Head Material, Head Size and Taper Geometric Optimization (opens in a new tab)

  16. Chondrolabral Damage in the Natural Hip Joint

    … the non-functional rim of the acetabulum of the hip joint and was resected when damaged or causing pain. However, there is increasing evidence suggesting the labrum plays a vital role in the healthy functioning of the hip. Contact stresses in acetabular articular cartilage can increase by 92% …

    whiterose Repository record for Chondrolabral Damage in the Natural Hip Joint (opens in a new tab)

  17. A tribological investigation into the wear and lifetime prediction of metal on plastic artificial hip implants

    Artificial hip implants are a useful medical intervention for patients with a compromised hip joint. Currently, due to limitations in the longevity of the device, hip implants are often associated with use in an aging or elderly population. Despite this, there remains a potential demand in a cohort …

    rice Repository record for A tribological investigation into the wear and lifetime prediction of metal on plastic artificial hip implants (opens in a new tab)

  18. Characterization and biological effects of wear particles from metal-metal hip implants

    … failure of conventional metal-polyethylene total hip arthroplasties. There has been a revived interest in metal-metal (MM) bearings, made of CoCrMo alloys; because of their very high wear resistance compared with conventional bearings. The work that forms the basis of this thesis attempts to …

    mcgill Repository record for Characterization and biological effects of wear particles from metal-metal hip implants (opens in a new tab)

  19. Modelling of Dynamic Edge Loading in Total Hip Replacements with ceramic on polyethylene Bearings

    The performance of total hip replacement (THR) devices can be affected by various factors such as quality of the tissues surrounding the joint, mismatch of the component centres or the cup positioning during hip replacement surgery. Experimental studies have shown that these factors can cause the …

    whiterose Repository record for Modelling of Dynamic Edge Loading in Total Hip Replacements with ceramic on polyethylene Bearings (opens in a new tab)

Page 1 of 2