  1. A dosimetric study of a heterogeneous phantom for lung stereotactic body radiation therapy comparing Monte Carlo and pencil beam calculations to dose distributions measured with a 2-d diode array

    … distributions were studied for two different phantom types: an in-house heterogeneous phantom and a homogeneous phantom. The motivation is to mimic the human anatomy during a lung SBRT treatment and incorporate heterogeneities into the pre-treatment Quality Assurance process, where measured …

    fau Repository record for A dosimetric study of a heterogeneous phantom for lung stereotactic body radiation therapy comparing Monte Carlo and pencil beam calculations to dose distributions measured with a 2-d diode array (opens in a new tab)

  2. Development of radiofrequency coils for magnetic resonance-guided particle therapy

    … and receive (both coils) fields was confirmed in homogeneous phantoms for different rotation angles of the MR coils. The body coil also achieved sufficient transmit power efficiency (0.18−0.27 μT/√W) in the central slice for a complete rotation of the phantom. In terms of image quality, the …

    heid-diss Repository record for Development of radiofrequency coils for magnetic resonance-guided particle therapy (opens in a new tab)

  3. Evaluation of the dosimetric accuracy of the AAA algorithm (Analytical Anisotropic Algorithm) of the eclipse treatment planning system

    … Absolute dosimetry was analyzed in a homogeneous phantom simulator and additionally, we constructed and characterized imageologically a thorax phantom to analyze the accuracy of the algorithm under conditions of inhomogeneity of the medium.

    un-colombia Repository record for Evaluation of the dosimetric accuracy of the AAA algorithm (Analytical Anisotropic Algorithm) of the eclipse treatment planning system (opens in a new tab)

  4. Hemoglobin oxygenation of a two-layer tissue-simulating phantom from time-resolved reflectance

    … the optical properties of tissue-simulating phantoms was examined. To quantify the accuracy of the technique in monitoring hemoglobin saturation, measurements were performed in a homogeneous phantom containing human erythrocytes in a scattering solution. The hemoglobin saturation of this …

    mcmaster Repository record for Hemoglobin oxygenation of a two-layer tissue-simulating phantom from time-resolved reflectance (opens in a new tab)

  5. Validation of a Monte Carlo based treatment planning system (TPS) for electron beams

    … dose distributions in the transverse plane in a homogeneous phantom. The verification data set was comprised of measurements performed for combinations of 6, 9, 12, 16, and 20 MeV beam energies with five standard field sizes and thirteen irregularly shaped fields under three phantom setups. The …

    mcgill Repository record for Validation of a Monte Carlo based treatment planning system (TPS) for electron beams (opens in a new tab)

  6. MR Safety of Implantable Medical Devices: In Silico Assessment Using Computational Human Models in 1.5 T and 3.0 T Conventional MRI Systems, and Analysis in Open-bore MRI at 1.2 T

    … F2182-19e2 standard. This approach utilizes a homogeneous phantom, which does not accurately represent the heterogeneous electrical properties of human tissues. In clinical scenarios, variations in anatomical location, implant placement, orientation, and incident electric fields differ …

    houston Repository record for MR Safety of Implantable Medical Devices: In Silico Assessment Using Computational Human Models in 1.5 T and 3.0 T Conventional MRI Systems, and Analysis in Open-bore MRI at 1.2 T (opens in a new tab) Embargoed until 2028-05-01

  7. Fluorescence enhanced optical tomography on breast phantoms with measurements using a gain modulated intensified CCD imaging system

    … optical imaging must be assessed in feasibility phantom studies. A novel intensified charge-coupled device (ICCD) imaging system has been developed to perform 3-D fluorescence tomographic imaging in the frequency-domain using near-infrared contrast agents. This study is unique since it (i) …

    tamu Repository record for Fluorescence enhanced optical tomography on breast phantoms with measurements using a gain modulated intensified CCD imaging system (opens in a new tab)

  8. ArcCheck Phantom with Tissue Equivalent Inserts for Validation of Treatment PlanningSystem Dose Calculation in Heterogenous Media

    … curves obtained in auniform medium of the water phantom.Verification of the dose calculation algorithm accuracy in heterogeneous mediumis a required part of the treatment planning system (TPS) commissioning process. Apartfrom validation of the dose calculation algorithm, it is also a test of the …

    ohiolink Repository record for ArcCheck Phantom with Tissue Equivalent Inserts for Validation of Treatment PlanningSystem Dose Calculation in Heterogenous Media (opens in a new tab)

  9. X-ray beam modelling in radiotherapy: the effect of lung inhomogeneities

    A lung phantom consisting of epoxy resin based analogs is developed in-house and a quality assurance method, which compares experimental CT numbers with theoretical CT numbers calculated from electronic cross sections, is described. Currently used photon beam inhomogeneity correction models and …

    waikato-masters Repository record for X-ray beam modelling in radiotherapy: the effect of lung inhomogeneities (opens in a new tab)

  10. Compact High-Data-Rate Implantable Antennas for Leadless Cardiac Pacemakers

    … band around 1.6 GHz. Simulation results within a homogeneous phantom (HP) of heart tissue indicate gain values of −32.4 dBi at 0.915 GHz, −27.94 dBi at 1.4 GHz, and −19.8 dBi at 2.45 GHz. The second contribution presents an ultra-compact implantable antenna featuring a central C-shaped slot. It …

    durham Repository record for Compact High-Data-Rate Implantable Antennas for Leadless Cardiac Pacemakers (opens in a new tab)

  11. Methods to Enhance Nuclear Magnetic Resonance Sensitivity at High Magnetic Field

    … Using the saddle coil in glycoCEST imaging of a homogeneous phantom resulted in an MTR asymmetry coefficient of variation as small as 5.2% over an 11 mm diameter ROI. Overall, the saddle coil provided a good compromise between globally homogeneous excitation and high sensitivity. Finally, it was …

    epfl Repository record for Methods to Enhance Nuclear Magnetic Resonance Sensitivity at High Magnetic Field (opens in a new tab)

  12. Novel Deflection Sensing and Actuation Methods for Needle Steering in Soft Tissue

    … by carrying out insertion experiments into homogeneous phantom and non-homogeneous biological tissues. The estimator maintains an adequate estimation accuracy up to a high insertion depth, as confirmed by insertion experiments into phantom and biological tissue samples. The proposed …

    alberta Repository record for Novel Deflection Sensing and Actuation Methods for Needle Steering in Soft Tissue (opens in a new tab)

  13. Cerebral oxygenation monitoring in neonates: improving and validating instrumentation

    … we have performed several studies with liquid phantoms simulating optical properties of neonatal brain tissue. We first conducted experiments with a simple, homogeneous phantom and then refined the set-up to model a more realistic two-layer geometry resembling skull and brain. Our studies showed …

    zurich Repository record for Cerebral oxygenation monitoring in neonates: improving and validating instrumentation (opens in a new tab) Restricted access

  14. Optimising Molecular Radionuclide Therapy: The Role of Quantitative SPECT/CT & PET/CT and Radiation Dosimetry

    … and 131I performance using:<br/>a. A cylindrical homogeneous phantom was used to assess the scintillation camera calibration factor (CF) (cps/MBq).<br/>b. A NEMA-IEC-Body Phantom incorporating six spheres of various sizes to calculate the concentration recovery coefficients (cRC).<br/><br/>2. PRRT …

    kings Repository record for Optimising Molecular Radionuclide Therapy: The Role of Quantitative SPECT/CT & PET/CT and Radiation Dosimetry (opens in a new tab)

  15. Monte Carlo Analysis and Physics Characterization of a Novel Nanoparticle Detector for Medical and Micro-dosimetry Applications

    … measured dose values in a cylindrical mouse phantom at 225 kV for x-ray irradiation at angles of 0, 90, 180, and 270˝. The NanoFOD exhibited small changes in angular sensitivity, with a coefficient of variation (COV) of 3.6% at 120 kV and 1% at 225 kV. When the NanoFOD was placed alongside a …

    duke Repository record for Monte Carlo Analysis and Physics Characterization of a Novel Nanoparticle Detector for Medical and Micro-dosimetry Applications (opens in a new tab)

  16. Caractérisation numérique de l'exposition électromagnétique des personnes en bandes HF et VHF

    Dans les environnements militaires, et plus particulièrement dans le domaine terrestre, de nombreux systèmes radioélectriques HF (de 3 à 30 MHz), VHF (de 30 à 300 MHz) et UHF (de 300 à 3000 MHz) sont utilisés. Ces systèmes remplissent plusieurs fonctions (communication longue et courte distance, …

    star-france Repository record for Caractérisation numérique de l'exposition électromagnétique des personnes en bandes HF et VHF (opens in a new tab)

  17. A new prompt gamma spectroscopy-based approach for range verification in proton therapy

    … with the proton range. We designed a multilayer phantom to mimic the irradiation of a deep-seated tumor. The phantom was composed of 15.5 cm of solid water (proxy of normal tissue), followed by 5 cm of liquid target filled with water-based solutions containing the marker element (tumor region) …

    trento Repository record for A new prompt gamma spectroscopy-based approach for range verification in proton therapy (opens in a new tab)