Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 92 for “"Horizontal Shear"”.
-
Horizontal Shear Connectors for Precast Prestressed Bridge Decks
… as well as for new bridge construction. The horizontal shear strength at the interface between the two interconnected elements is of primary importance in order to provide composite action. The strength of the bond between the two precast members should be high enough to prevent any …
-
Analysis of the AASHTO LFRD Horizontal Shear Strength Equation
… in the deck to the girders is done across a shear interface between the two elements. The transfer occurs through the cohesion of the concrete at the interface and then through the shear reinforcement across the interface. Adequate shear strength is essential to the success of the …
-
Horizontal Shear Transfer Between Ultra High Performance Concrete And Lightweight Concrete
… Of particular importance is the design of the horizontal shear reinforcement connecting the bridge deck to the top flange of the beams. Without adequate shear transfer, the flexural and shearing capacities will be greatly diminished. The current design equations from ACI and AASHTO were not …
-
Horizontal Shear Transfer for Full-Depth Precast Concrete Bridge Deck Panels
… systems with their full composite strength, the horizontal shear resistance provided at the slab-to-beam interface must be quantified through further investigation. Currently, all design equations, both in the AASHTO Specifications and the ACI code, are based upon research for cast-in-place …
-
Delineating Pierre formation fracture reservoirs using compressional and horizontal shear wave seismic data near Florence, Fremont County, Colorado
Includes bibliographical references.
-
Interface Shear Strength in Lightweight Concrete Bridge Girders
… In order to develop composite action, adequate horizontal shear resistance must be provided at the interface. As lightweight concrete is increasingly being used in bridge designs, it is important to understand the horizontal shear behavior of lightweight concrete. The current AASHTO LRFD …
-
Second Order Effects in Concrete Insulated Wall Panels
… the unique experimental information herein, The Shear Flow method and a new method termed The Shear Slip Method were evaluated to estimate horizontal shear failure. The Shear Flow method, when used properly, results in perhaps an overly conservative prediction of horizontal shear strength but …
-
Investigation of bond in unreinforced concrete interfaces for partial depth repairs and new construction
This thesis presents an experimental study on the horizontal shear strength of reinforced concrete slabs and beams with unreinforced concrete-to-concrete interfaces. Current design provisions for new construction and repair applications in ACI 318-19 and ACI 562-19 codes attribute a low capacity …
-
Composite action in bridge I-girder systems
… sufficient composite action to resist the horizontal shear at the girder-to-deck interface. The new systems include a debonded interface with formed shear key protruding from the precast girders and steel connectors for concrete girders; $1{1\over 4}$ in. diameter steel shear studs and a …
-
Advancements in Imaging of Concrete Members Using Shear Waves
… employing dry point contact transducers emitting horizontal shear waves significantly increased the efficiency of data acquisition and enabled using imaging techniques for nondestructive evaluation of concrete members. Reverse time migration (RTM) is a mechanics-based imaging technique that has …
-
Unintended composite action in beam and slab bridges
… use of any mechanical connectors to resist the horizontal shear at the steel-concrete interface during bending. However, reports from bridge tests have shown that composite action was found to develop in beam and slab bridges which were not compositely built. Based on the available literature …
-
Investigation of the in plane seismic response of solid tilt-up wall systems
… wall panels and the base slab to provided horizontal sliding resistance without considering how each of these remedies may influence the other. Since vertical uplift resistance of the panel – slab connectors is ignored in design, any vertical load capacity they have will further increase …
-
Effects of a Geostrophic Current on the Propagation and Generation of Internal Tides
… that the reflection is determined by the horizontal shear of the current $V_x$ through varying the effective frequency $f_{eff}$. The modal energy conversion $P_n$ is determined by the vertical shear of the current $V_z$, i.e. the horizontal variation of the density $\rho_x$ as a result of …
-
Composite Action in Prestressed NU I-Girder Bridge Deck Systems Constructed with Bond Breakers to Facilitate Deck Removal
… from simple 3D models developed to simulate horizontal shear transfer in composite girders. Sixteen small scale push-off tests were conducted to investigate the influence of surface preparation, bond breakers (epoxy and roofing felt), and interface reinforcement properties (yield strength, …
-
Observations of misovortices within the 7 January 2014 Long Lake-Axis-Parallel lake-effect snow band during the Ontario Winter Lake-effect Systems Project
… convergence boundaries associated with cyclonic horizontal shear zones that likely originate from solenoidally-forced secondary circulations within these warm-core bands. In most cases, the shear zone is co-located with a sharp horizontal gradient in radar reflectivity, which corresponds to the …
-
Static stability as an aid in numerical baroclinic-zone analysis
… a FNWF front-location parameter proportional to horizontal shear of the thermal wind which is dependent on mandatory level data only.
-
Comparative Analysis of Stresses in a Building Frame
… to the footings.</p> <p>In high buildings, the horizontal shear due to the wind load is very large; and since it is impracticable to put diagonal braces between the columns, it is customary to make the building frame rigid enough to resist the horizontal shear by virtue of the stiffness of the …
-
Seismic Assessment and Retrofit of Unreinforced Masonry Buildings using Fibre Reinforced Polymer Materials
… loaded walls, that are likely to fail in a shear mode, as such failures are commonly observed in earthquakes. FRP materials have become popular in recent years, but limited test data, and design guidelines exist for their use on URM walls. The experimental part of this included seventeen …
-
Impact of bidirectional seismic shearing on volumetric response of sand deposits
… one of vertical compression and two of horizontal shear, what drives the response of soils in the field. Experimental studies have shown that, for the case of soil liquefaction, neglecting one of the two horizontal shear components can potentially lead to an underestimation of seismic …
Page 1 of 5