Investigation of liner-host pipe strength and its influence on behaviour at ring fracture
Cured-in-place pipe (CIPP) liners are among the most widely used trenchless rehabilitation methods for water distribution pipelines because they can restore structural performance without conventional open-cut replacement. The structural response of a CIPP liner depends not only on its material and …
-
Structural Performance of Cast-In-Place Pipe Liners at Perforations and Ring Fractures in the Host Pipe
… the structural performance of Cast-In-Place Pipe (CIPP) liners for pressure pipes, around areas of deterioration in the host pipe, specifically perforations and ring fractures. To evaluate the liner behaviour around perforations in a host pipe, an investigation using finite element analysis …
-
Numerical Assessment on the Mechanical Performance of Pressure Pipe CIPP Liner with Local Defects in the Outer Host Pipe
… to assess the effects of local defects in the host pipe on the mechanical performance of the CIPP liner subject to internal pressure, axial deformation and flexure loading conditions.For a CIPP liner subject to internal pressure with local circular void defects in the host pipe, the limit state …
-
Non-linear Analysis Of Liners For Rigid Pipe Rehabilitation
Most damaged pipelines are structurally safe, but due to hydraulic requirements renovations are required. One solution is to apply an internal polymer liner. The critical external fluid pressure at which the liner may collapse is the target of this research. The Finite Element Method (FEM) is used …
-
Service Performance of a Cured In Place Polymer Pipe Liner for Deteriorated Cast Iron Pressure Pipes
Although Cured-In-Place Pipe (CIPP) liners have been used extensively across North America, their in-situ performance in deteriorated pipe conditions has not been extensively studied. The purpose of this research work is to develop a better understanding of the service performance of CIPP liners in …
-
EXPERIMENTAL INVESTIGATION OF THE STRUCTURAL MECHANICS AND PERFORMANCE OF CLOSE-FIT FLEXIBLE LINERS INSTALLED IN CORRUGATED STEEL STRUCTURES
… steel culverts lined with cured-in-place-pipe liners under vehicle and hydrostatic loads through the conduct of full scale experiments. Further, with the tested structures, section and material properties of the liners are characterized and the relevant quality assurance practices are …
-
Polymer Culvert Liner Response to External Water Pressure Considering Buoyancy and Non-Circular Geometry
… methods for trenchless rehabilitation of old pipes, little research has been conducted in regard to the rehabilitation of culverts using CIPP considering the impacts of shallow cover, where the water pressure increases with depth lead to significant buoyancy. Buckling is one of the important …
-
Material Characterization and Testing of Cured-in-Place Pipe to Resist Earthquake Related Ground Deformation
… results of full-scale tests on Cured-In-Place Pipe (CIPP) to evaluate its performance under earthquake induced ground deformation. The CIPP used in this work is commercially available as Aqua-pipe, manufactured by Sanexen Environmental Services, Inc. to rehabilitate water mains. The …
-
Field Measurements of Surface Displacements from Pipe Bursting
Two field studies of surface displacements during pipe bursting were conducted. The first field study consisted of a controlled experiment in clay soil. Three vitrified clay pipelines, each at a different burial depth, were up-sized to high density polyethylene (HDPE) pipes using static pipe …
-
Experimental Study on the Longitudinal Strain Behavior of Polymer Pipe Liners Crossing Joints in Reinforced Concrete Pipes under Surface Loading
… infrastructure consists of reinforced concrete pipes (RCPs) with bell-and-spigot joints. As these pipelines age, trenchless rehabilitation methods such as Cured-in-Place Pipe (CIPP) and Spray-in-Place Pipe (SIPP) liners are increasingly adopted as cost-effective and minimally disruptive …
-
Long-term creep of encased polymer liners
… inconveniences in replacing deteriorated sewer pipelines by conventional excavation methods, the trenchless or 'no-dig' technology is being extensively used. In trenchless technology, a polymer or reinforced polymer is applied to the inside of the deteriorated host pipe to prevent ground water …
-
Designing a framework to guide renewal engineering decision-making for water and wastewater pipelines
… urgent need for renewal of water and wastewater pipelines. A pertinent gap remains in understanding the relationship between deteriorated host-pipe conditions and renewal products cost and performance. This work provides a framework Decision-Support System that supports water and wastewater …
-
Performance Enhancement Of Controlled Low-Strength Grout Material (CLSM) For Annulus Voids Of Sliplined Culverts
… in the United States. In this method, a new pipe (liner) having a smaller diameter is inserted into the existing pipe (host pipe), and the annular space between the two pipes is filled with different grouting materials. Controlled Low Strength Material (CLSM) is a commonly used grout material …
-
Design of a vision-based automatic cutting robot for CIPP rehabilitation of underground drainage pipe
<p>Cured-in-place pipe rehabilitation is one of the most widely used trenchless renewal methods for buried pipelines. Installation of a CIPP liner results in a tight fit within the host pipe, but meanwhile, the lateral connections are also covered. Therefore, various manually operated cutters are …
-
Testing of Innovative Pipe Renewal Liners for Renovation of Potable Water Distribution Pipelines
… network due to one or a combination of pipe breaks, leakages, or aesthetic water quality problems, resulting from aging and internal corrosion. Various polymer-based products such as Cured-in Place Pipe (CIPP) lining have been widely employed in structural water main rehabilitation …
-
Cementitious Liners in Reinforced Concrete Pipes
… the performance of damaged reinforced concrete pipes with a focus on developing design approaches to examine the required thickness of cementitious liners to restore strength to resist earth and vehicle loads. Design seeks to prevent the development of additional cracking within the damaged …
-
Evaluating ASCE MOP 145 Annular Gap Impact on Existing Standards for Non-Reinforced Cured-in-Place Pipe
… of annular gap on non-reinforced cured-in-place pipe (CIPP) required liner thickness using the American Society of Civil Engineers’ (ASCE) Manual of Practice 145 (ASCE MOP 145) equations for comparison against existing North American design, installation, and testing standards for CIPP. ASCE …
-
Experimental and numerical evaluations of corrugated steel pipe and rehabilitation using a geosynthetic cementitious composite MAT
Corrugated steel pipes (CSPs) are widely used in transportation infrastructure but are vulnerable to corrosion and structural deterioration. Geosynthetic Cementitious Composite Mats (GCCMs) are increasingly used for corrugated steel pipe (CSP) rehabilitation; however, their structural performance …
-
The Chemo-Mechanical Characterization of the Long-Term Performance of Glass Fibre Reinforced Cured-in-Place Pipe Liners
… for a glass fibre reinforced cured-in-place-pipe (CIPP) liner to evaluate its performance and assess its chemical durability. The test matrix involves two chemical and two mechanical tests, performed in parallel to draw connections between mechanical performance and characteristics of the …
-
Performance of Trenchless Rehabilitations for Culvert, Sewer, and Maintenance Hole Structures
… backfill) on steel and reinforced concrete pipe behaviour. Additionally, the voids were rehabilitated using simple trenchless solutions and the impact on pipe capacity was explored. Furthermore, rehabilitation is also commonly performed on access structures (i.e. maintenance holes) to …