Factors Influencing Contrast Resolution of Cone Beam CT Using the CB MercuRay
… landmarks in both quality and quantity. Hounsfield Unit (HU) values represent a grayscale that is standardized on CT machines relative to the density of water and air. It has been reported that the HU value represents an actual value of the bone density. However, recent studies at Loma …
-
Magnetic Resonance Only Planning Validation Using Synthetic CT by MVision
… as D95, and examined image agreement through Hounsfield-unit mean absolute error, pixel-wise fidelity, structural similarity index measure, difference signal-to-noise ratio, relative electron density drift, and radiomics deltas. Results: Across the evaluated cases, dose agreement was high and …
-
Image quality and dose of an accelerator-integrated kV CBCT systems
… the exception of high contrast resolution and Hounsfield Unit (HU) accuracy. CTDI of OBI was higher than that of XVI which was related to the different designs and imaging protocols between the two systems.
-
Effects of osteoporosis on bone density of osteotomy sites in orthognathic surgery
… DEXA)를 비교함으로써 특정 부위의 골 밀도를 평가하는데 있어서 CT의 Hounsfield unit (HU) 측정의 유용성을 조사하는 것과 악교정수술 시 골 절단 부위의 HU을 측정하여 대조군과 실험군(골감소증 및 골다공증)의 골 밀도를 비교함으로써, 골 절단 부위에 대한 골다공증의 영향을 평가하는 것이었다. 아주대학교병원에서 facial CT와 DEXA를 모두 촬영한 80명의 환자가 본 연구에 포함되었다. 악교정수술 시 골 절단이 이뤄지는 부위 중 상악골에서 3부위, 하악골에서 4부위가 region of …
-
Reproducibility of Two Non-Consecutive Scans Using a NewTom 3G; in Vitro Model
… of mineral density measurement expressed in Hounsfield Units (HU) using a phantom device with known mineral densities and the NewTom 3G Cone Beam Computerized Tomography (CBCT). Materials and Methods: A phantom device made of 21 HA cylindrical disks with known densities was fabricated. The …
-
Generation of Pseudo-CT using Two Sets of MRI Scans for MRI-only Radiation Therapy
… average MAE across all patients is 40.3 ± 3.0 Hounsfield Unit (HU). Our proposed method shows promising results in using a multi-variable polynomial prediction model to predict CT numbers from MRI images. The generated pCT images closely match the reference-CT image and the MAE results are …
-
Development and Implementation of An Anthropomorphic Pediatric Spine Phantom For The Assessment of Craniospinal Irradiation Procedures In Proton Therapy
… by measuring the relative stopping power and Hounsfield unit of potential phantom materials. The materials selected as bone, tissue, and cartilage substitutes were Techron HPV Bearing Grade (RSP 1.3, HU 595.6), solid water (RSP 1.004, HU 16), and blue water (RSP 1.07, HU 86), respectively. The …
-
A Method for Online Dose Prediction for Image Guided Proton Therapy
… recent quality assurance CT (QACT), the standard hounsfield unit (HU) to relative stopping power (RSP) curve used in the treatment planning system (TPS), as well as a simple gaussian smoothing to lessen the local effects of CBCT artifacts. The comparison itself involved interpolating each line …
-
Multimodal CT imaging in acute ischemic stroke
… was found in the literature providing an opportunity to devise a novel assessment method. Well developed collaterals were associated with imaging and clinical markers for good outcome as well as some potential biomarkers including atrial fibrillation and blood fibrinogen level. Relative cerebral …
-
Μελέτη οστικής πυκνομετρίας με νεότερες απεικονιστικές μεθόδους σε ασθενείς με χρόνια αποφρακτική πνευμονοπάθεια
… sought to investigate the possible usefulness of Hounsfield Unit (HU) measurements in lumbar vertebrae as a means to identify osteopenia or osteoporosis.Our results showed that osteoporosis and osteopenia are very common in patients with COPD, and are more frequently found in patients with more …
-
Machine learning-based classification of knee osteoarthritis : impact of cartilage segmentation precision
… process for identifying knee OA from Hounsfield Unit (HU) values in computed tomography (CT) and magnetic-resonance imaging (MRI) files. This process proved costly in time and required expertise in specialized imaging software, which is unlikely to be replicated by all clinics or other …
-
Μελέτη της ποιότητας εικόνας και της ακρίβειας καθορισμού συγκέντρωσης υδροξυαπατίτη σε ανθρωπόμορφο ομοίωμα με υπολογιστική τομογραφία δύο ενεργειών: Σύγκριση πρωτοκόλλων απεικόνισης
… 40-140keV μέσω των οποίων καταγράφηκαν οι τιμές Hounsfield Unit σε ένα πλήθος από ROI. Στην συνέχεια υπολογίστηκαν οι δείκτες SNR και CNR και δημιουργήθηκαν τα αντίστοιχα διαγράμματα ως προς την ενέργεια. Μέσω αυτών εξάγαμε συμπεράσματα σχετικά με την ενέργεια των μονοχρωματικών εικόνων η οποία …
-
Computed tomography aortic valve calcium scoring and its association with adverse events following transcatheter aortic valve implantation (TAVI)
… in CTA scans was performed at a fixed Hounsfield Unit (HU) threshold of 850 HU (HU 850 approach) and at a patient-specific threshold, where the HU threshold was set by multiplying the mean luminal attenuation of the ascending aorta by 2 (+100 % HUAorta approach). The primary endpoint of …
-
Improving Cone-Beam Computed Tomography Based Adaptive Radiation Therapy with Deep Learning
… images with reduced artifacts and more accurate Hounsfield Unit values, as found in CT scans. Second, the model's generalizability is investigated and discussed, along with potential solutions to address the generalizability problem. Third, two DL models are designed to extract and combine …
-
Automatisierte Quantifizierung der Lipiodolverteilung zur Vorhersage der therapeutischen Wirksamkeit der transarteriellen Chemoembolisation bei Leberkrebs
… tumors, treated with cTACE from 2012-2018. Using Hounsfield Unit (HU) cut-off values, the presence and density of Lipiodol deposition on 24h CT scans was characterized. Different Lipiodol deposition patterns within a volumetric tumor mask were identified according to the features homogeneity, …
-
Systemic Integration of Retrospective Analysis for Optimizing CT Imaging Practice
… several key computational parameters, including Hounsfield unit thresholds, kernel size, and histogram bin width. Using clinical CT data, these parameters were systematically evaluated to determine configurations that produce stable and reliable noise estimates across different organs. The third …
-
Basis Vector Model Method for Proton Stopping Power Estimation using Dual-Energy Computed Tomography
… the performance of SECT-based methods is the Hounsfield unit (HU) degeneracy in the presence of tissue composition variations. Dual-energy computed tomography (DECT) has shown the potential of reducing uncertainties in proton SPR prediction via scanning the patient with two different source …
-
Image-Based Deep Learning Enables the Reduction of Gastro-Intestinal Toxicity in Pelvic Radiotherapy
… sCT from treatment planning MR, delivering Hounsfield Unit (HU) mean error of -2.8HU, mean absolute error of 36.8HU, and rectal dosimetric accuracy within 0.1% of gold standard CT calculation. Calculation of grade 2 (G2) late rectal bleeding toxicity risk using DL sCT was accurate for both …
-
Process planning for the subtractive rapid manufacturing of heterogeneous materials: Applications for automated bone implant manufacturing
… via an iterative process of thresholding the Hounsfield Unit (HU) data from a computed tomography (CT) scan, thereby delineating regions of progressively increasing bone density. Then a harvesting algorithm is developed to determine a suitable location to generate the bone implant from within …