Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 102 for “"Hounsfield units"”

  1. Lung nodule modeling and detection for computerized image analysis of low dose CT imaging of the chest.

    … probability density of the image intensity (or Hounsfield units) versus the radial distance measured from the centroid – center of mass - of typical nodules. This probability density showed that the nodule spatial support is within a circle/square of size 10 pixels; i.e., limited to 5 mm in …

    louisville Repository record for Lung nodule modeling and detection for computerized image analysis of low dose CT imaging of the chest. (opens in a new tab)

  2. Design of a new Anthropometric Calibration Phantom for improving Accuracy of the Hounsfield Unit to Electron Density Calibration Curve

    … use in proton radiotherapy is the measurement of Hounsfield Units (HU) for the determination of electron density. The primary source of this uncertainty is due to the relative difference in scatter between the patient and electron density calibration phantoms. In this dissertation, I will show how …

    ohiolink Repository record for Design of a new Anthropometric Calibration Phantom for improving Accuracy of the Hounsfield Unit to Electron Density Calibration Curve (opens in a new tab)

  3. A Survey of CT Phantom Considerations for the Study of Blooming Artifacts as Observed in CT Coronary Angiography Studies: A Preliminary Study

    … of blooming with respect to measured density in Hounsfield Units (HU), of5mm diameter plaques. Custom software was developed to provide reproducibleobjective measurements of plaque size. Plaque diameter was measured using a seriesof axially distributed profiles centered on the object. …

    ohiolink Repository record for A Survey of CT Phantom Considerations for the Study of Blooming Artifacts as Observed in CT Coronary Angiography Studies: A Preliminary Study (opens in a new tab)

  4. Patient-Specific Finite Element Analysis for Mandibular Fracture Fixation

    … the mandible that are 1mm spaced based on the Hounsfield Units of these points. The mandible geometry was sectioned to simulate a fracture. Muscle and mastication forces were added to replicate post-surgery loading. Using a standard linear miniplate, this material model was compared with two …

    unlv Repository record for Patient-Specific Finite Element Analysis for Mandibular Fracture Fixation (opens in a new tab)

  5. Preparation of embolic protection devices for embolic characterization

    … bring about tissue characterization in terms of Hounsfield Units (HU), were compared. The techniques evaluated in this study included embedding a specimen each in (a) a paraffin cassette, (b) a polymethyl methacrylate (PMMA) block, (c) paraffin followed by sectioning and mounting on glass slides, …

    sjsu Repository record for Preparation of embolic protection devices for embolic characterization (opens in a new tab)

  6. A Quantitative Analysis of Four Dimensional Computed Tomography

    … standard clinical thoracic images by only a few Hounsfield units. Measured geometric precision along with the accuracy of mean CT#s observed in 4DCT phase images indicate that 4DCT is an appropriate imaging technique for treatment planning.

    alberta Repository record for A Quantitative Analysis of Four Dimensional Computed Tomography (opens in a new tab)

  7. Manufacturing of 3D Printed Boluses for Use In Electron Radiation Therapy

    … wax, superstuff or water and sealed. Materials Hounsfield units were analyzed, along with the structure stability. This method is evaluated by scanning the 3D printed bolus. The dose conformity is improved compared to that with no bolus. By generating a patient specific 3D printed bolus there is …

    fau Repository record for Manufacturing of 3D Printed Boluses for Use In Electron Radiation Therapy (opens in a new tab)

  8. ACCOUNTING FOR THE FLASH REGION IN BREAST RADIOTHERAPY: HU OPTIMIZATION OF VIRTUAL BOLUS AND IMPACT OF BRASS MESH ON SKIN

    … to simulate its clinical impact. Different Hounsfield Units (HU) were assigned to the VB to determine the most effective value. Five post-mastectomy breast cancer patients treated with VMAT were retrospectively analyzed. Plan normalization values, conformity indexes, and dosimetric criteria …

    fau Repository record for ACCOUNTING FOR THE FLASH REGION IN BREAST RADIOTHERAPY: HU OPTIMIZATION OF VIRTUAL BOLUS AND IMPACT OF BRASS MESH ON SKIN (opens in a new tab)

  9. Pulmonary structure and function analysis in systemic sclerosis : clinical assessment of complicating interstitial lung disease and pulmonary vasculopathy

    … as the threshold value of densities expressed in Hounsfield units. A prerequisite for an optimal percentage was its correlation with baseline DLCO% predicted. Regression analysis for the relation between DLCO% predicted and the nth percentile density was optimal at 85% (Perc85). There was …

    leiden Repository record for Pulmonary structure and function analysis in systemic sclerosis : clinical assessment of complicating interstitial lung disease and pulmonary vasculopathy (opens in a new tab)

  10. Characterization of Multispectral Visible and X-ray CT Imagery of Hydromorphic Soils

    … soil composition complexity and the closeness of Hounsfield units of mineral oxidation. Based on relative attenuation in histograms of CT images obtained by multi-energy X-ray spectra, the suggestion of using multi-energy X-ray CT imagery is given to simplify material-specific segmentation.

    guelph Repository record for Characterization of Multispectral Visible and X-ray CT Imagery of Hydromorphic Soils (opens in a new tab)

  11. The Production of Hydroxyapatite Standards, Used for Post CBCT Scan Hounsfield Unit Calibration

    … set of phantoms in the oral cavity, to derive Hounsfield Units (HU). However, due to the polychromatic x-ray source in CBCT scanners, variation in average grey level for a single phantom exists, as a function of location.This thesis will focus on using common biomaterials, used in biomedical …

    ohiolink Repository record for The Production of Hydroxyapatite Standards, Used for Post CBCT Scan Hounsfield Unit Calibration (opens in a new tab)

  12. Significancer of Osteoporosis in Facial Bone Density using the Computed Tomography Scan

    … was analyzed in the region of interest, and the Hounsfield units were measured. There was a significant difference in the mean bone density of the mid-facial bones between the osteoporosis group and the control group (p=0.000). For both groups, each of comparison of the 7 skeletal regions was …

    ajou Repository record for Significancer of Osteoporosis in Facial Bone Density using the Computed Tomography Scan (opens in a new tab) Embargoed until 9999-12-31

  13. Asociación entre la densidad del músculo psoas y la fuga anastomótica en cirugía por cáncer colorrectal

    … defined with a cutoff less than or equal to 49.5 Hounsfield Units, was associated with an increased risk of anastomosis leakage [OR 4.45 CI 95% (1.89 - 10.5) p < 0.001], postoperative ileus [OR 2.53 CI 95% (1.16 – 5.53) p. 0.02] and surgical site infection [OR 3.08 CI 95% (1.35 – 7.05) p. 0.01]. …

    rosario Repository record for Asociación entre la densidad del músculo psoas y la fuga anastomótica en cirugía por cáncer colorrectal (opens in a new tab)

  14. Optimization of Computed Tomography Calibration Curve for Proton Therapy Treatment Planning

    … system relies on the conversion from the Hounsfield units (HU) of each voxel in the patient CT scan to the proton stopping power ratio (SPR). The aim of this study is to investigate the potential improvement in determining proton SPR using single energy computed tomography (SECT) to reduce …

    fau Repository record for Optimization of Computed Tomography Calibration Curve for Proton Therapy Treatment Planning (opens in a new tab)

  15. Parámetros de la masa muscular medidos por tomografía computarizada en una población sana. Fundación Cardioinfantil – Instituto de Cardiología, Bogotá, 2014-2018

    … mass density of the right psoas muscle was 56,1 Hounsfield Units (HU), (56,9 HU for women and 55,3 HU for men) and left psoas was 55,5 HU (56,0 HU for woman and 54,5 HU for man). The muscle mass area of the right psoas showed a median of 834,5 mm2 (684,3 mm2 for woman and 1189,1 mm2 for men), …

    rosario Repository record for Parámetros de la masa muscular medidos por tomografía computarizada en una población sana. Fundación Cardioinfantil – Instituto de Cardiología, Bogotá, 2014-2018 (opens in a new tab)

  16. A Comparative Analysis of Water-Equivalent Path Length of Tissue Samples using a Fast Monolithic Proton Radiography System

    … scans must undergo a conversion to translate Hounsfield Units (HU) to relative stopping power (RSP). This conversion can be inaccurate by up to 4%, and is currently the greatest cause of uncertainty in proton therapy. While there exist several ways around this, directly measuring RSP with …

    gatech Repository record for A Comparative Analysis of Water-Equivalent Path Length of Tissue Samples using a Fast Monolithic Proton Radiography System (opens in a new tab)

  17. The Development and Implementation of An Anthropomorphic Head Phantom For The Assessment of Proton Therapy Treatment Procedures

    … of ±3%. The relative stopping power (RSP) and Hounsfield Units (HU) were measured for potential phantom materials and a human skull was cast in tissue-equivalent Alderson material (RLSP 1.00, HU 16) with anatomical airways and a cylindrical hole for imaging and dosimetry inserts drilled into …

    uthsc Repository record for The Development and Implementation of An Anthropomorphic Head Phantom For The Assessment of Proton Therapy Treatment Procedures (opens in a new tab)

  18. Assessment of Human Alveolar Bone Density by Using Volumetric CT Machine

    … for density evaluations. Bone density in Hounsfield units (HU) was assessed in a standardized implant area superimposed on the images, and also subjectively evaluated by 2 independent examiners using the Lekholm & Zarb (1985) classification. Density measurements in HU in most of the areas, …

    loma-linda Repository record for Assessment of Human Alveolar Bone Density by Using Volumetric CT Machine (opens in a new tab)

  19. Fotobiomodulação com led e laser no reparo de alvéolo mandibular de coelhos (Oryctolagus cuniculus)

    … tomography for evaluation of bone density in Hounsfield units. Soon after, were cut and stained with hematoxylin and eosin for histological and histomorphometric to determination of the type of collagen. The results of clinical, tomographic, histologic, histomorphometric and collagen suggest …

    brazil-ufmg Repository record for Fotobiomodulação com led e laser no reparo de alvéolo mandibular de coelhos (Oryctolagus cuniculus) (opens in a new tab)

  20. Reproducibility of Two Non-Consecutive Scans Using a NewTom 3G; in Vitro Model

    … of mineral density measurement expressed in Hounsfield Units (HU) using a phantom device with known mineral densities and the NewTom 3G Cone Beam Computerized Tomography (CBCT). Materials and Methods: A phantom device made of 21 HA cylindrical disks with known densities was fabricated. The …

    loma-linda Repository record for Reproducibility of Two Non-Consecutive Scans Using a NewTom 3G; in Vitro Model (opens in a new tab)

Page 1 of 6