Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 112 for “"Human Body Model"”.

  1. Towards Qualification of Female Human Body Model for Virtual Testing: Setup for 50th percentile female human body model and parametric study of the boundary conditions

    … biomechanical evaluations relied on post-mortem human surrogates (PMHS), standard physical crash testing today is primarily conducted using Anthropomorphic Test Devices (ATDs). However, ATDs possess structural limitations: their rigid responses cannot fully replicate complex human soft-tissue and …

    chalmers Repository record for Towards Qualification of Female Human Body Model for Virtual Testing: Setup for 50th percentile female human body model and parametric study of the boundary conditions (opens in a new tab)

  2. Objective Seat Comfort Assessment using Finite Element Human Body Model Simulations

    Finite Element (FE) Human Body Models (HBMs) are used for crash safety assessment but are potential tools for seat comfort assessment. However, it is unclear what parameters from such simulations that predict comfort. In this thesis, potential modifications of a HBM are outlined to make it more …

    chalmers Repository record for Objective Seat Comfort Assessment using Finite Element Human Body Model Simulations (opens in a new tab)

  3. Vehicle crash reconstructions using FE human body model to improve injury predictions

    FE Human Body Models (HBMs) represent an important researching tool for assessing occupant injuries on tissue level. Although prior research has overtime led to considerable improvements, further validation of today’s HBMs is needed in order to ensure model biofidelity. In this thesis, SAFER HBM v9 …

    chalmers Repository record for Vehicle crash reconstructions using FE human body model to improve injury predictions (opens in a new tab)

  4. Industrialisation of a Finite Element Active Human Body Model for Vehicle Crash Simulations

    The Total HUman Model for Safety (THUMS), developed by Toyota, is a numerical finite element model of the human body to enable studies of vehicle accidents by computer aided simulations. Recently a new muscle package, referred to as the SAFER Active Human Body Model (AHBM) which provides the THUMS …

    chalmers Repository record for Industrialisation of a Finite Element Active Human Body Model for Vehicle Crash Simulations (opens in a new tab)

  5. Enhancing Shoulder Joint Biofidelity in the VIVA+ Human Body Model and Evaluating its Response

    Previous versions of the VIVA+ human body models have demonstrated excessive shoulder stiffness compared to experiments conducted on postmortem human subjects. This study aims to enhance the biofidelity of the shoulder in the VIVA+ model. Data from studies involving postmortem human subject …

    chalmers Repository record for Enhancing Shoulder Joint Biofidelity in the VIVA+ Human Body Model and Evaluating its Response (opens in a new tab)

  6. Development of a Human Body Model for the Analysis of Side Impact Automotive Thoracic Trauma

    … interior components. Injury is sustained to human structural components such as the thoracic cage or shoulder, and to the internal visceral components such as the heart, lungs, or aorta. Understanding the mechanism behind these injuries is an important step in improving the side impact crash …

    waterloo Repository record for Development of a Human Body Model for the Analysis of Side Impact Automotive Thoracic Trauma (opens in a new tab)

  7. Validation of a Lumbar Spine Fracture Injury Criterion for Finite Element Human Body Model Simulations

    … the aim was to validate a newly developed model of the human lumbar spine with an associated strain-based fracture injury risk function (IRF). To reach this aim, the new lumbar spine model was used in reconstructions of tests on isolated lumbar spines, the lumbar spine model was integrated …

    chalmers Repository record for Validation of a Lumbar Spine Fracture Injury Criterion for Finite Element Human Body Model Simulations (opens in a new tab)

  8. Biofidelity assessment of the activen human body model compared to volunteer braking and steering maneuvers

    Active human body models have contributed to the safety device design and helped build a safer road. Validation is essential for the development of all human models and SAFER A-HBM is no exception. The validation of SAFER A-HBM in multidirection would contribute to the further development of it. …

    chalmers Repository record for Biofidelity assessment of the activen human body model compared to volunteer braking and steering maneuvers (opens in a new tab)

  9. The Development of a Numerical Human Body Model for the Analysis of Automotive Side Impact Lung Trauma

    … of automotive side impact traumas. A numerical model that can predict such injuries in crash simulation is essential to the process of designing a safer motor vehicle. The focus of this study was to develop a numerical model to predict lung response and injury in side impact car crash scenarios. …

    waterloo Repository record for The Development of a Numerical Human Body Model for the Analysis of Automotive Side Impact Lung Trauma (opens in a new tab)

  10. The human body model VIVA+ in far-side collisions: A validation and evaluation study of HBM usage

    … However, with more advanced computers, virtual human body models are becoming increas ingly useful. With this as a background, this project aims to validate the male VIVA+ model, perform identical simulations using a female version of the VIVA+ human body model and subsequently compare these …

    chalmers Repository record for The human body model VIVA+ in far-side collisions: A validation and evaluation study of HBM usage (opens in a new tab)

  11. Computational Modeling of the Cervical Spinal Cord: Integration into a Human Body Model to Investigate Response to Impact

    … in large gaps in understanding. Computational Human Body Models (HBM) are an alternative and potentially important tool to investigate the risk of SCI. A key challenge in applying contemporary HBM to study SCI is the need for a biofidelic model of the spinal cord, which accurately predicts the …

    waterloo Repository record for Computational Modeling of the Cervical Spinal Cord: Integration into a Human Body Model to Investigate Response to Impact (opens in a new tab)

  12. Investigation of Neck Posture and Muscle Activity on Cervical Spine Impact Kinematics Using a Finite Element Human Body Model

    … studies but may be informed by computational human body models (HBMs). However, three limitations in neck models have been identified: (1) neck muscle controllers were often tuned to a narrow set of specific load cases, (2) neck models were unable to predict the S-shape (upper cervical spine …

    waterloo Repository record for Investigation of Neck Posture and Muscle Activity on Cervical Spine Impact Kinematics Using a Finite Element Human Body Model (opens in a new tab)

  13. Developing Lumbar Spine Fracture Injury Risk Functions for Frontal Impact Anthropomorphic Test Devices using Paired Human Body Model Simulations

    … a new Finite Element (FE) lumbar spine model and a corresponding Injury Risk Function (IRF), integrated into the SAFER Human Body Model (SHBM) to enhance fracture risk prediction capabilities in car crash simulations. This thesis aimed to develop new lumbar spine injury prediction …

    chalmers Repository record for Developing Lumbar Spine Fracture Injury Risk Functions for Frontal Impact Anthropomorphic Test Devices using Paired Human Body Model Simulations (opens in a new tab)

  14. Development of general hydrodynamic modelling method for whiplash nerve injury: Using high-fidelity data from the ViVA+ human body model

    … head lags. Some usual sections in the human body which can be affected by a whiplash motion are spinal ligaments, dorsal root ganglion, and invertebral discs in the neck. In addition, there are studies that has recorded pressure transients in the spinal canal when necks are exposed of …

    chalmers Repository record for Development of general hydrodynamic modelling method for whiplash nerve injury: Using high-fidelity data from the ViVA+ human body model (opens in a new tab)

  15. Finite Element Human Body Model-based Injury Prediction using Machine Learning: Development of simulation-based surrogate models for injury metrics

    Models of the human body, both physical and virtual, have been vital tools for the design of safer vehicles. Finite element models of the human body are now becoming widely used for evaluating safety systems. With the introduction of future designs like autonomous vehicles that affect the nature of …

    chalmers Repository record for Finite Element Human Body Model-based Injury Prediction using Machine Learning: Development of simulation-based surrogate models for injury metrics (opens in a new tab)

  16. Active Muscle Control in Human Body Model Simulations - Implementation of a feedback control algorithm with standard keywords in LS-DYNA

    … add posture control and muscular response to the human body. A model for active muscle control has previously been implemented in the Chalmers Active Human Body Model using subroutines written in the FORTRAN programming language. In order to decrease conflicts with future software updates and …

    chalmers Repository record for Active Muscle Control in Human Body Model Simulations - Implementation of a feedback control algorithm with standard keywords in LS-DYNA (opens in a new tab)

  17. Human centric virtual driven product development - Using FE simulation to compare passive versus active muscle activity for human body model development

    … pelvis and use it to simulate the effect on a human body model (HBM). A literature review was conducted in order to find muscle tissue parameters that could be used in the simulation of muscles around the pelvis. Three studies were chosen to compare muscle tissue parameters, the last of which …

    chalmers Repository record for Human centric virtual driven product development - Using FE simulation to compare passive versus active muscle activity for human body model development (opens in a new tab)

  18. A Parametric Study of Shoulder Belt Interactions with the PIPER Scalable Child Human Body Model in Frontal and Frontal Offset Impacts

    … to physical crash tests. Finite Element Human Body Models have the potential to become a powerful tool in the virtual assessment of injury tolerances, kinematic behavior and interaction with vehicle interior design. Although substantial efforts have been contributed to the development of …

    chalmers Repository record for A Parametric Study of Shoulder Belt Interactions with the PIPER Scalable Child Human Body Model in Frontal and Frontal Offset Impacts (opens in a new tab)

  19. Spinal Curvature Update of the SAFER Human Body Model: A study on the effect of spinal curvature in frontal and run-off road crash scenarios

    The human body is a complex system made of various tissues, making it a difficult task to model in a biofidelic manner. It is of importance to be able to accurately do this in order to predict the risk of injury when exposed to large magnitudes of acceleration, e.g. in car crashes. Prior research …

    chalmers Repository record for Spinal Curvature Update of the SAFER Human Body Model: A study on the effect of spinal curvature in frontal and run-off road crash scenarios (opens in a new tab)

Page 1 of 6