Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 29 for “"Human Subject Testing"”.

  1. Transverse-Plane Ankle Rotation for Lower-Limb Amputees Using Two Novel Prostheses

    … plane was developed. Second, exploratory human subject testing was performed to identify a pattern of motion that reduces transverse-plane torque at the socket without reducing torsional stiffness. The results indicate that this can be achieved by coupling transverse-plane ankle rotation …

    washington Repository record for Transverse-Plane Ankle Rotation for Lower-Limb Amputees Using Two Novel Prostheses (opens in a new tab)

  2. Pneumatic ergonomic crutches

    … study, sleeve orthosis performance was examined. Human subject testing indicated significantly improved wrist posture, increased loading sharing to the cuff, reduced and redirected palmar pressure while using the orthosis. In the second study, the fully-developed PEC was presented. The PEC …

    uiuc Repository record for Pneumatic ergonomic crutches (opens in a new tab)

  3. Biomechanical Investigation of Elite Place-Kicking

    … developed to quantify ball flight trajectory. Human subject testing revealed that the ideal timing of proximal-to-distal motion (application of the summation of speed principle) plays a key role in achieving maximum kicking potential. However, the quality of a place kick cannot be determined …

    nebraska Repository record for Biomechanical Investigation of Elite Place-Kicking (opens in a new tab)

  4. A Tunable Silicone Phantom Arm With Embedded Arteries for Cardiovascular Device Testing

    … realistic and repeatable conditions. While human subject testing remains the standard, it introduces significant intersubject variability, ethical constraints, and limited experimental control. To overcome these limitations, a modular phantom arm system was developed to enable controlled …

    tamu Repository record for A Tunable Silicone Phantom Arm With Embedded Arteries for Cardiovascular Device Testing (opens in a new tab) Embargoed until 2028-05-01

  5. A Tunable Silicone Phantom Arm With Embedded Arteries for Cardiovascular Device Testing

    … realistic and repeatable conditions. While human subject testing remains the standard, it introduces significant intersubject variability, ethical constraints, and limited experimental control. To overcome these limitations, a modular phantom arm system was developed to enable controlled …

    tamu Repository record for A Tunable Silicone Phantom Arm With Embedded Arteries for Cardiovascular Device Testing (opens in a new tab) Embargoed until 2028-05-01

  6. A Novel Method and Two Exoskeletons for Whole-arm Gravity Compensation

    … The Panto-Arm Exo was specifically used in human subject testing, in which fourteen users wore electromyography electrodes and performed simple arm movements and holding tasks. While the Panto-Arm Exo did not undergo stringent design improvements or user-specific optimization, the device was …

    vt Repository record for A Novel Method and Two Exoskeletons for Whole-arm Gravity Compensation (opens in a new tab)

  7. Multimodal assessment of Parkinson's disease using electrophysiology and automated motor scoring

    … of Parkinson's disease signs and symptoms in human patients. Off -line analysis of data collected with the system was subsequently shown to allow discrimination between normal and simulated parkinsonian conditions. The main contributions of the work were in three areas: 1) Evidence of the …

    gatech Repository record for Multimodal assessment of Parkinson's disease using electrophysiology and automated motor scoring (opens in a new tab)

  8. Design of a Passive Ankle Prosthesis with Energy Return That Increases with Increasing Walking Velocity

    … pylon prostheses. After fabricating and testing the optimized design using a repeatable robot trajectory, the device was found to convert 26.6% of input translational work as rotational work, accounting for 63.1% of modeled rotational work. Through human subject testing, the device was …

    marquette Repository record for Design of a Passive Ankle Prosthesis with Energy Return That Increases with Increasing Walking Velocity (opens in a new tab)

  9. Mechanical performance characterization of manual wheelchairs using robotic wheelchair operator with intermittent torque-based propulsion

    … propulsion to emulate the intermittent human propulsion cycle with an existing robotic wheelchair tester, 2) to investigate the influence of incremental mass additions to the wheelchair frame on over-ground propulsion characteristics, 3) to demonstrably improve the performance of a …

    gatech Repository record for Mechanical performance characterization of manual wheelchairs using robotic wheelchair operator with intermittent torque-based propulsion (opens in a new tab)

  10. Biomechanical Assessment of Tricuspid Regurgitation Using Experimental and Computational Approaches

    … approaches are under development and undergoing human subject testing in compassionate uses cases, but their mechanical effects on the tricuspid apparatus are currently unknown and may provide valuable information regarding device durability and tissue remodeling. The twofold objective of this …

    gatech Repository record for Biomechanical Assessment of Tricuspid Regurgitation Using Experimental and Computational Approaches (opens in a new tab)

  11. Robust Algorithms for Unattended Monitoring of Cardiovascular Health

    … device for monitoring parameters relating to a subject’s cardiac health in his or her home, because it is used consistently and requires no change in daily habit. The present work demonstrates the ability to accurately capture clinically relevant ECG metrics, pulse transit time based blood …

    rit Repository record for Robust Algorithms for Unattended Monitoring of Cardiovascular Health (opens in a new tab)

  12. Control Design and Implementation of an Active Transtibial Prosthesis

    … presented by Winter. However, after completing human subject testing, the Marquette Prosthesis was insufficient in trying to match the gait profile of those who varied from this textbook stride. Active transtibial prostheses typically apply finite state control algorithms that struggle with …

    marquette Repository record for Control Design and Implementation of an Active Transtibial Prosthesis (opens in a new tab)

  13. Efficacy of Immersive Virtual Reality Gameplay in Environmental Attitude Change: The Case of Abandoned Offshore Oil Platforms in Santa Barbara

    … A quasi-experimental study was conducted with human subject testing, utilizing pre- and post-experiment questionnaires to measure changes in participants’ awareness, perceptions, and empathy toward marine conservation. Statistical analysis using the Wilcoxon Signed-Rank Test was performed to …

    calpoly Repository record for Efficacy of Immersive Virtual Reality Gameplay in Environmental Attitude Change: The Case of Abandoned Offshore Oil Platforms in Santa Barbara (opens in a new tab)

  14. Quantifying tympanic membrane dynamics in otitis media using low coherence interferometry

    … pressure (MEP). Followed by phantom studies and human subject testing, a total of 42 ear datasets from pneumatic LCI system and tympanometry were acquired from 30 pediatric outpatient subjects at Carle Foundation Hospital (Urbana, IL) to assess the clinical significance in relation to OM. As a …

    uiuc Repository record for Quantifying tympanic membrane dynamics in otitis media using low coherence interferometry (opens in a new tab)

  15. Non-invasive microwave-based sensor system for monitoring hydration levels in patients with electromagnetic waves

    … explores the use of dielectric properties of human tissues, particularly at microwave frequencies, to detect variations in tissue water content as a proxy for hydration status. Building on prior work from the London Met University Rescaling project, which introduced BaFe-inclusion-based …

    london-metro Download PDF for Non-invasive microwave-based sensor system for monitoring hydration levels in patients with electromagnetic waves (opens in a new tab)

  16. Interactive variable resistance exercise approach to maximizing force output based on lifting velocity

    … (IVRE) approach to maximizing force output. The testing apparatus was a Smith machine modified for pneumatic resistance and equipped with pressure, position, and velocity transducers. The resistance level varied interactively with the user based on velocity to accommodate for changing …

    colostate Repository record for Interactive variable resistance exercise approach to maximizing force output based on lifting velocity (opens in a new tab)

  17. MANUAL DEXTERITY PERFORMANCE UNDER REDUCED WORKING TEMPERATURES

    … ambient temperatures and simple reaction time. Human subject testing, statistical modeling and analyses were used in this research. The objectives of this research were: (1) To determine if a decrement in human manual dexterity performance occurs with a reduction in ambient temperature. (2) To …

    nebraska Repository record for MANUAL DEXTERITY PERFORMANCE UNDER REDUCED WORKING TEMPERATURES (opens in a new tab)

  18. A human analog for benchmarking vestibular tests in a roto-tilt chair

    … thesis then brings focus to the development and testing of an experimental model that will be used to simulate the vestibulo-ocular reflex (VOR) about pitch, roll, and yaw axes. A sensor array consisting of accelerometers and gyroscopes was built to simulate vestibular function with the sensors …

    alabama Repository record for A human analog for benchmarking vestibular tests in a roto-tilt chair (opens in a new tab)

  19. Exploration of Constant-Force Wristbands for a Wearable Health Device

    … the seven key requirements. The design and testing of a wrist worn sensing band used to gather relationship data among band tension, sensor pressure, patient comfort, and pulsatile signal quality is also presented. Human subject testing (IRB2020-268) was performed on a wristband with an …

    byu Repository record for Exploration of Constant-Force Wristbands for a Wearable Health Device (opens in a new tab) Download PDF for Exploration of Constant-Force Wristbands for a Wearable Health Device (opens in a new tab)

  20. Online Adaptation of User State Estimation in a Powered Hip Exoskeleton using Machine Learning

    … robotic power to augment the capabilities of the human using them. Lower limb exoskeletons in particular are designed to aid in mobility tasks, rehabilitation, and other forms of human ability augmentation. Hip exoskeletons apply assistance at the hip joint, one of the largest contributors to …

    gatech Repository record for Online Adaptation of User State Estimation in a Powered Hip Exoskeleton using Machine Learning (opens in a new tab)