Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 20 of 31 for “"Human Surrogates"”
-
Biomechanical Responses of Small Female Human Surrogates during Frontal Sled Tests using a Realistic Vehicle Environment
… two ATDs have not been compared to post-mortem human surrogate (PMHS) responses using a realistic, driver-seat environment to assess biofidelity or ability to predict injury. Therefore, the objective of this study was to compare the responses of the two ATDs and small female PMHS in matched …
-
Biomechanical Responses of Human Surrogates under Various Frontal Loading Conditions with an Emphasis on Thoracic Response and Injury Tolerance
… was to evaluate the biomechanical responses of human surrogates under various frontal loading conditions. This objective was divided into three sub-objectives: 1) to evaluate the biofidelity of the current frontal impact ATDs, 2) to evaluate the effect of different safety restraints on occupant …
-
Lower Extremity Biomechanical Response of Female and Male Post-Mortem Human Surrogates to High-Rate Vertical Loading During Simulated Under-Body Blast Events
During an under-body blast (UBB) event, an improvised explosive device (IED) delivers a high-energy blast beneath a military vehicle, exposing mounted Warfighters to considerable risk of severe lower extremity injuries. Loftis and Gillich (2014) determined that the lower leg and ankle region is the …
-
Investigating the Thoracic Biomechanical Responses of Rear Seated 50th Percentile Male Anthropomorphic Test Devices and Post Mortem Human Surrogates During Frontal Motor Vehicle Collisions
… male ATDs, and 50th percentile male post mortem human surrogates (PMHS) seated in the rear seat of modern vehicles, which have various seat geometries and restraint types, during frontal MVCs. Emphasis is placed on comparisons between the thoracic responses of the three human surrogates e.g., …
-
Bridging Surrogates: A Multi-Model Approach to Understanding Human Lung Injury from High-Rate Blunt Trauma Environment
… fully understood, as existing research relies on human surrogates, including in vivo animal models, cadaveric animals, post-mortem human subjects (PMHS), and finite element (FE) models. Each surrogate serves a distinct purpose, some enabling observation of physiological responses and others …
-
An Investigation into Pressure-Based Abdominal Injury Criteria Using Isolated Liver and Full-Body Post-Mortem Human Subject Impact Tests
… between vascular pressure and liver injury in human surrogates and in pressurized ex vivo human and porcine livers when subjected to blunt impacts. The objective of this work is to further investigate the relationship between pressure and liver injury using full-body post-mortem human …
-
Correlation of Liver Injury and Biomechanical Predictors: A Study of Lateral and Oblique Impacts to Post‐Mortem Human Subjects
… between vascular pressure and liver injury in human surrogates and in pressurized <i>ex vivo</i> human and porcine livers when subjected to blunt impact. The objectives of this work are to further investigate the relationship between pressure and liver njury using post‐mortem human surrogates. …
-
Development and Validation of a Finite Element Dummy Lower Limb Model for Under-body blast Applications
… test devices (ATDs) are mechanical human surrogates designed to transfer loads and display kinematics similar to a human subject. ATDs have been used successfully by the automotive industry for decades to quantify human injury during an impact and assess safety measures. Currently …
-
Quantifying the Kinematics of Injury Biomechanics: Several Applications Incorporating Human Volunteers and Surrogates
… (ATDs) necessitates benchmarking of current surrogates and further analysis of an occupant's biomechanical response in automobile collisions. This thesis presents data from low-speed frontal sled tests performed with human volunteers, a Hybrid III 50th percentile male ATD, and post mortem …
-
Towards Qualification of Female Human Body Model for Virtual Testing: Setup for 50th percentile female human body model and parametric study of the boundary conditions
… biomechanical evaluations relied on post-mortem human surrogates (PMHS), standard physical crash testing today is primarily conducted using Anthropomorphic Test Devices (ATDs). However, ATDs possess structural limitations: their rigid responses cannot fully replicate complex human soft-tissue and …
-
Biomechanical Response of Human Volunteers and Surrogates in a Variety of Loading Regimes
… a major threat to the health and welfare of humans. Over 120,000 deaths and over 30,000,000 non-fatal injuries are estimated annually in the United States. The leading causes of nonfatal injuries vary with age, but falls, motor vehicle collisions (occupants), and being struck by or against …
-
EXPLORATION OF LOWER EXTREMITY INJURY IN THE UNDER BODY BLAST ENVIRONMENT USING A HUMAN BODY FINITE ELEMENT MODEL
… blast (UBB) environment has involved post-mortem human subjects (PMHS) or Anthropomorphic Test Devices (ATD). One emerging alternative to the use of these human surrogates are computational Human Body Models (HBMs). HBMs offer a unique advantage to overcome the shortcomings of PMHS and ATD …
-
Injury risk and uterine biomechanics in pregnant motor vehicle occupants : the influence of gestational age and posture
… of MVC-related injury are identified using human surrogates. While these models have been adapted for use in pregnant occupant motor vehicle safety, the pregnant surrogates are based on manually measured seated anthropometry, which don’t consider changes in internal anatomy, and supine …
-
Computational Investigations of the Effect of Posture and Sex on Spacecraft Occupant Injury Under Dynamic Loads
… (such as those when landing). The increase in human spaceflight necessitates this gap be investigated to ensure safer spacecraft design for a diverse crew. The effect of spinal posture variation on spinal injury outcomes in spacecraft occupants also remains to be studied. Spacecraft crew …
-
Development of a generic morphable motorcycle model for crash analysis
… test of a KTM Duke 390 with a post-mortem human subject (PMHS) impacting the side of a Honda Accord. This was replicated in the simulation using a human body model (HBM), a Honda Accord car model (National Highway Traffic Safety Administration, n.d.), and the morphed KTM Duke 390 model. In …
-
Gender Dependent Biomechanical Properties of the Isolated Thoracic Disc Segment
… engineering perspective, analytical modeling and human surrogates are used to understand injury mechanisms and help mitigate injuries. Over the last forty years, characterization of the biomechanical properties of post mortem human testing has lead to the development and validation of instrumented …
-
Injury and Impact Responses of the Abdomen Subjected to Seatbelt Loading
… mechanical responses of abdomen by subjecting human surrogates to impact conditions such as rigid-bar, seatbelt and airbags, an agreeable correlation between abdominal injuries and injury metric that is not readily available. Such a scenario translates directly to the lack of an injury …
-
Simulation and Analysis of Human Phantoms Exposed to Heavy Charged Particle Irradiations Using the Particle and Heavy Ion Transport System (PHITS)
… radiation fields without the need to expose human subjects. One of the most widely known is RANDO phantom. This phantom is used primarily for medical X-ray applications, but a similar design known as "MATROSHKA" is now being used for space research and exposed to heavy ion irradiations from …
-
Investigations of Modern-Day Head Injuries: Safety Provided by Youth Football Helmets and Risk Posed by Unmanned Aircraft Systems
… flight over people is made legal, the risk of human injury due to UAS impacts must be quantified and understood. For this work, UAS head impacts were carried out on post-mortem human surrogates (PMHS) (i.e. cadavers) and the Hybrid III ATD. PMHS impacts were used to assess the likelihood of …
-
Low Severity Neck Injury from Side Impact
… guide future research into the development of human surrogates/ human models to ensure that they more accurately replicate side impacts at multiple impact angles (such as oblique angles), as this thesis shows that LSNI occurs at various side impact angles and not just at 90 degrees. A MADYMO …
Page 1 of 2