Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 136 for “"Hydraulic loading"”.

  1. Abrasion on Concrete Surfaces Caused by Hydraulic Loading with Water-Borne Sands

    Hydraulic structures play an important role in regulation and transport of water in reservoirs as well as open channels. They are also useful for flow measurement. Examples of such structures include spillways, stilling basins, weirs, gates, and culverts. These structures commonly have concrete …

    concordia Download PDF for Abrasion on Concrete Surfaces Caused by Hydraulic Loading with Water-Borne Sands (opens in a new tab)

  2. Effects of hydraulic loading and laundry detergent on the operation of aerobic package treatment systems

    … operation of aerobic package treatment systems: hydraulic retention time, laundry detergents, and hydraulic surges. To determine the effect of hydraulic retention time on system performance, six bench scale activated sludge systems were constructed. Wastewater from an actual residence was …

    vt Repository record for Effects of hydraulic loading and laundry detergent on the operation of aerobic package treatment systems (opens in a new tab)

  3. The Influence of Hydraulic Loading Rate on Nitrification Performance in a Two-Stage Biological Aerated Filter Pilot Plant

    … the study, the system was operated at different hydraulic loading rates that resulted in a range of applied organic and ammonia mass loadings. Performance was monitored regularly for water quality parameters in the effluent and along the length of the reactors. It was found that nitrification …

    vt Repository record for The Influence of Hydraulic Loading Rate on Nitrification Performance in a Two-Stage Biological Aerated Filter Pilot Plant (opens in a new tab)

  4. Evaluation of organic and hydraulic loading on the performance of a roughing trickling filter tower using sessil media to treat a high strength industrial wastewater

    … a 26 feet tall tower. The effects of organic and hydraulic loadings on the performance of the tower were examined. The characteristics of the influent wastewater on treatment performance were also determined. The wastewater, comprised mainly of waste acetic acid, some acetone, other organic …

    vt Repository record for Evaluation of organic and hydraulic loading on the performance of a roughing trickling filter tower using sessil media to treat a high strength industrial wastewater (opens in a new tab)

  5. Cold-climate nitrification on plastic media trickling filters

    … dosing and intermittent dosing, with average hydraulic loading rates ranging from 0.5 to 1.9 l/sq. m (.) s. Two types of cross-flow media were used: (1) 45 degree media with a specific surface area of 98 sq. m/cu. m in the pretreatment trickling filter and (2) 60 degree media with a specific …

    iastate Repository record for Cold-climate nitrification on plastic media trickling filters (opens in a new tab)

  6. Nitrification of Landfill Leachate by Biofilm Columns

    … wood chips. The effects of varied concentration loading, varied hydraulic loading, and nitrification inhibitors were studied. Varied ammonia concentration did not have a huge impact on the ammonia removal rates (77-87%) in the reactor with pine wood media. The ammonia removal rates showed a …

    vt Repository record for Nitrification of Landfill Leachate by Biofilm Columns (opens in a new tab)

  7. Effects Of Reduced Ras And Volume On Anaerobic Zone Performance For A Septic Wastewater Biological Phosphorous Removal System

    … than typical anaerobic zone volume (1.08 hours hydraulic retention time or HRT). Three identical parallel biological nutrient removal (BNR) pilot plants were fed with strong, highly fermented (160 mg/L VFAs), domestic/industrial wastewater from a full scale wastewater treatment facility (WWTF). …

    ucf Repository record for Effects Of Reduced Ras And Volume On Anaerobic Zone Performance For A Septic Wastewater Biological Phosphorous Removal System (opens in a new tab)

  8. The Fate of Nitrogen in Wastewater Applied to Rapid Infiltration-Percolation Basins

    … cover versus scarified surface and differential hydraulic loading rates on the nitrogen species within the effluent discharged from the pilot units.

    sdstate Repository record for The Fate of Nitrogen in Wastewater Applied to Rapid Infiltration-Percolation Basins (opens in a new tab)

  9. Development of a Combined Reed Bed – Freezing Bed Technology to Treat Septage in Cold Climates

    … were utilized to produce a freezing bed design loading map for North America based on temperature normals. Field scale planted and unplanted reed bed – freezing bed systems were constructed and tested with varying hydraulic loading rates (1.9-5.9 m/y) and solid loading rates (43-144 kg/m2/y) …

    ottawa-retro Repository record for Development of a Combined Reed Bed – Freezing Bed Technology to Treat Septage in Cold Climates (opens in a new tab)

  10. Sustainable Drinking Water Treatment for Small Communities Using Multistage Slow Sand Filtration

    … testing of its performance under increased hydraulic loadings and elevated influent turbidity together with cold water conditions. The primary goal of this research was to demonstrate the reliability of multistage filtration for small communities in northern climates with reference to the …

    waterloo Repository record for Sustainable Drinking Water Treatment for Small Communities Using Multistage Slow Sand Filtration (opens in a new tab)

  11. High-Rate Infiltration-Percolation Treatment of Wastewater to Satisfy Effluent Requirements

    … compare effects of the type of basin surface and hydraulic loading rate on the quality of the renovated water. Other areas of the EPA project included: determination of the hydraulic loading rates acceptable to the soil, determination of the nitrogen and phosphorous removal accomplished within the …

    sdstate Repository record for High-Rate Infiltration-Percolation Treatment of Wastewater to Satisfy Effluent Requirements (opens in a new tab)

  12. Exploring a Lab-scale Cascade Upflow Bioreactor System for Nitrogen Removal Via Biosorption Activated Media

    … The proposed filtration technology can control hydraulic gradients, prevent clogging and settlements, and increase hydraulic loading while removing more nutrients in an integrated physicochemical and microbiological treatment process. The two green sorption media being tested in this study …

    ucf Repository record for Exploring a Lab-scale Cascade Upflow Bioreactor System for Nitrogen Removal Via Biosorption Activated Media (opens in a new tab)

  13. Exploring the Interplay of Operational Conditions, Microbial Communities, and Water Quality in Drinking Water Ozone-Biofiltration

    … the impacts of intermittent ozonation, variable hydraulic loading, and seasonal fluctuations on treatment performance and identify performance indicators and operational benchmarks for an ozone-biofiltration system, 2) characterize microbial communities in granular activated carbon biofilters …

    wvu Repository record for Exploring the Interplay of Operational Conditions, Microbial Communities, and Water Quality in Drinking Water Ozone-Biofiltration (opens in a new tab)

  14. Ecological studies on high-rate biological filters with special reference to microbial biosynthesis and nitrification

    … 'roughing' filter to alleviate the seasonal overloading of low rate filters on Hereford sewage treatment works - caused by wastes from cider production - or as a two stage high rate process to provide complete sewage treatment. Four mineral and four plastic primary filter media and two plastic …

    aston Download PDF for Ecological studies on high-rate biological filters with special reference to microbial biosynthesis and nitrification (opens in a new tab)

  15. Development of a Passive Filter for Polishing Municipal Lagoon Effluent-Lab and Field Scale Studies

    … include identifying the best media type and hydraulic loading rate for an unsaturated filter, evaluating the hydraulic retention time (HRT) and adsorptive capacity for a saturated filter, and pilot-scale testing of the technology. The experimental variables include unsaturated media, filter …

    ottawa-retro Repository record for Development of a Passive Filter for Polishing Municipal Lagoon Effluent-Lab and Field Scale Studies (opens in a new tab)

  16. Development of Soluble Manganese Sorptive Contactors for Enhancing Potable Water Treatment Practices

    … via adsorption onto larger media (2.0-6.4mm) at hydraulic loading rates of 16-24 gpm/ft², thus producing less head loss and furthering the development of soluble Mn sorptive contactors to be implemented in water treatment facilities. Research was conducted by executing laboratory- and pilot-scale …

    vt Repository record for Development of Soluble Manganese Sorptive Contactors for Enhancing Potable Water Treatment Practices (opens in a new tab)

Page 1 of 7