Showing 1 to 20 of 37 for “"Hydrodynamic focusing"”.

  1. Three-Dimensional Hydrodynamic Focusing for Integrated Optofluidic Detection Enhancement

    … sensitivity and specificity is desired through hydrodynamic focusing. Novel 3D hydrodynamic focusing designs were developed and implemented on the ARROW platform, an optofluidic lab-on-a-chip single-molecule detector device. Microchannels with cross-section dimensions smaller than 10 μm were …

    byu Repository record for Three-Dimensional Hydrodynamic Focusing for Integrated Optofluidic Detection Enhancement (opens in a new tab) Download PDF for Three-Dimensional Hydrodynamic Focusing for Integrated Optofluidic Detection Enhancement (opens in a new tab)

  2. Microfluidic Hydrodynamic Focusing For Flow Cytometry And Diffusion-Mixing

    … device, and the analyte can be maneuvered hydrodynamically into the optical interrogation zone. In addition, since flow is laminar, the concentration distributions of the solutes can be explicitly calculated over the volume of the device. In this work, a microfluidic hydrodynamic focusing …

    cornell Repository record for Microfluidic Hydrodynamic Focusing For Flow Cytometry And Diffusion-Mixing (opens in a new tab)

  3. Controlled liposome formation and solute encapsulation with continuous-flow microfluidic hydrodynamic focusing

    Liposomes enable the compartmentalization of compounds making them interesting as drug delivery systems. A drug delivery system (DDS) is a transport vehicle for a drug for in vivo drug administration. Drugs can be encapsulated, bound, or otherwise tethered to the carrier which can vary in size from …

    maryland Repository record for Controlled liposome formation and solute encapsulation with continuous-flow microfluidic hydrodynamic focusing (opens in a new tab)

  4. Numerical investigation of hydrodynamic focusing and coulter principle in a microfluidic device

    … aspects. First one is the analysis for the hydrodynamic focusing in microfluidic Coulter Counter. In recent years, many microfluidic Coulter Counter designs have utilized a technique termed “hydrodynamic focusing” to control the particle’s trajectory. Hydrodynamic focusing uses two sheath …

    louisville Repository record for Numerical investigation of hydrodynamic focusing and coulter principle in a microfluidic device (opens in a new tab)

  5. Design of a microfluidic chip for three dimensional hydrodynamic focusing in cell cytometry applications

    The Focusing of cells is an important part of cytometry applications and can be achieved by different techniques. 3D hydrodynamic focusing has generated considerable interest over the last few years, owing to its simplicity and its independence from an electric potential for focusing. Current 3D …

    concordia Download PDF for Design of a microfluidic chip for three dimensional hydrodynamic focusing in cell cytometry applications (opens in a new tab)

  6. Application of Hydrodynamic Focusing in Flow Cytometry and Solve Partial Differential Equations using Machine Learning

    Microfluidic flow cytometry is gaining popularity as it is portable and reduces the usage of sample and sheath fluid. However, the design of these devices has primarily relied on empirical and trial-and-error approaches, there is a need for a more precise understanding of how fluidic and …

    guelph Repository record for Application of Hydrodynamic Focusing in Flow Cytometry and Solve Partial Differential Equations using Machine Learning (opens in a new tab)

  7. Signal-to-Noise Measurements and Particle Focusing in Liquid-Core Waveguides

    … waveguides (ARROWs) and the application of hydrodynamic focusing to the waveguides. These concepts are presented as a method to improve the detection capabilities of the ARROW platform. The improvements are specifically targeted at achieving single molecule detection (SMD) with the devices. …

    byu Repository record for Signal-to-Noise Measurements and Particle Focusing in Liquid-Core Waveguides (opens in a new tab) Download PDF for Signal-to-Noise Measurements and Particle Focusing in Liquid-Core Waveguides (opens in a new tab)

  8. Development of techniques for rapid isolation and separation of particles in digital microfluidics

    … properties). They include magnetic collection, hydrodynamic focusing, dielectrophoresis positioning of the particles. The magnetic collection method, a rather simple but effective and widely used in biochemistry, is implemented on DMF for capturing target analytes. The hydrodynamic focusing …

    ubc Repository record for Development of techniques for rapid isolation and separation of particles in digital microfluidics (opens in a new tab) Download PDF for Development of techniques for rapid isolation and separation of particles in digital microfluidics (opens in a new tab)

  9. Design and development of an apparatus for microencapsulation of pancreatic cell islets

    … first requirement is met by the utilization of hydrodynamic focusing as a feeding system in our device. The second requirement is met by the employment of selective withdrawal as an encapsulation method. With the intent to shed light to the physical mechanisms occurring in the apparatus, we …

    greece Repository record for Design and development of an apparatus for microencapsulation of pancreatic cell islets (opens in a new tab)

  10. Toward a sensor platform combining three-dimensional electrochemical arrays and microfluidics

    … section explores the possible application of hydrodynamic focusing to selectively functionalise a three-dimensional surface. Commercial multi-physics COMSOL software was used to simulate and develop the fabricated hydrodynamic focusing device. A convergent bonding fabrication technique was …

    auckland-ms Repository record for Toward a sensor platform combining three-dimensional electrochemical arrays and microfluidics (opens in a new tab)

  11. An investigation into fuel cells and flow cytometers optimal design

    … the simulation results that blood cells were hydrodynamically focused within a range of sheath flow rate, and it was observed that bigger flow cytometer exit pipe diameter requires higher sheath flow rates for hydrodynamic focusing of blood cells. The simulation results were compared to the …

    lsu-thes Repository record for An investigation into fuel cells and flow cytometers optimal design (opens in a new tab)

  12. Hydrodynamic Focused Passive Separation Under Continuous Flow in a Microfluidic Chip

    … circuit to create variable flow rates for hydrodynamic focusing to drain channels and collection outlets. By varying the diameter of the sample inlet connection into the reservoir, the particle position was influenced significantly, which enabled desired separations. Additionally it was …

    calpoly Repository record for Hydrodynamic Focused Passive Separation Under Continuous Flow in a Microfluidic Chip (opens in a new tab)

  13. Fluorescence activated sorting of antibody-labeled islets using an EPICS Elite ESP flow cytometer

    … of high shear. The second suggest that the hydrodynamic focusing of the sheath fluid when it meets the pancreas solution is great enough to fragment the islets. It was also determined that phycoerythran is better suited to fluorescently label islets for fluorescence-activated sorting due …

    iastate Repository record for Fluorescence activated sorting of antibody-labeled islets using an EPICS Elite ESP flow cytometer (opens in a new tab)

  14. Microfluidic Platforms for Focal Stimulation of Muscle Cells and Large-scale Studies of Synaptogenesis

    … focal delivery: 1) a laminar flow-based hydrodynamic focusing device that operates in an open chamber, and 2) a modified Transwell that operates based on area-selective diffusion of soluble species to the basal side of myotubes. We further developed cell micropatterning methods coupled …

    washington Repository record for Microfluidic Platforms for Focal Stimulation of Muscle Cells and Large-scale Studies of Synaptogenesis (opens in a new tab)

  15. Inertial Focusing of Particles in Curved Microchannels

    … One of these techniques is inertial focusing of particles in microchannels. The particles and channel interact to cause lateral migration of particles to equilibrium positions within channel cross-section in flow regime where inertia and viscosity of fluid are finite. Inertial …

    clemson Repository record for Inertial Focusing of Particles in Curved Microchannels (opens in a new tab)

  16. Nanomaterials characterization and bio-chemical sensing using microfabricated devices

    … However, the key components of the system, hydrodynamic focusing and optical systems, make conventional cytometers complex, large, and expensive. To eliminate these drawbacks, a dielectrophoretic particle focusing technique combined with MEMS is explored to replace the hydrodynamic focusing …

    texas Repository record for Nanomaterials characterization and bio-chemical sensing using microfabricated devices (opens in a new tab)

  17. NUMERICAL ANALYSIS OF LIPID NANOPARTICLE DIALYSIS USING A FLOW FOCUSING MICROFLUIDIC PLATFORM FOR PSEUDO-MEMBRANE PURIFICATION

    … membrane-free purification strategy using a flow-focusing microfluidic platform that functions as a pseudo-membrane system. A combined analytical and numerical framework was developed to study diffusion-driven transport during LNP dialysis under laminar flow conditions. Finite-element simulations …

    jhu Repository record for NUMERICAL ANALYSIS OF LIPID NANOPARTICLE DIALYSIS USING A FLOW FOCUSING MICROFLUIDIC PLATFORM FOR PSEUDO-MEMBRANE PURIFICATION (opens in a new tab) Embargoed until 2027-05-01

  18. Development of a microfluidic flow cytometer for plant protoplast analysis and manipulation by means of laser radiation pressure

    … techniques to improve data quality: By adding hydrodynamic focusing we improve data consistency and reduce clogging. To improve signal to noise ratio we fabricated a series of PDMS micro-lenses, improving light capture. We also improve detection by examining two different signal processing …

    iastate Repository record for Development of a microfluidic flow cytometer for plant protoplast analysis and manipulation by means of laser radiation pressure (opens in a new tab)