Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 14 of 14 for “"Hydrostatic testing"”
-
Water quality effects during hydrostatic-testing on corrosion behavior of AISI 316L austenitic stainless steel piping
Includes bibliographical references (leaves 115-118).
-
Understanding the Effects of Hydrogen, Hydrostatic testing and Mill- scale on SCC of Pipelines in Near-Neutral pH Environment
… of occasional over-load cycles during hydrotesting on pipelines in the field can explain this discrepancy. Furthermore, hydrogen involvement in this type of cracking, during both crack initiation and growth, has been confirmed in several studies. However, the presence of disbonded coatings …
-
TESTING AND ANALYSIS OF ADDITIVELY MANUFACTURED BUOYANT PARTS
… analysis and the experimental results for hydrostatic testing of hollow aluminum parts produced using liquid metal jet printing (LMJP) additive manufacturing (AM) are reported. Two variants of hollow metal parts were tested, a single enclosed piece meant to be attached externally to a …
-
Design and assembly of a standard compliant testing facility for locally manufactured industrial valves
… by the availability of required (necessary) testing facilities. Currently, these facilities are not generally available and the test procedures are not well known. The aim of this dissertation was to review international valve testing procedures, based on standards. Furthermore, the aim was …
-
Study of Microbiologically Influenced Corrosion Using Electrochemical Techniques in Oil and Gas Systems
… methods, such as visual inspection, ultrasonic testing, and hydrostatic testing, are effective but labor-intensive and not ideal for detecting MIC.This dissertation introduces Split Cell Zero Resistance Ammetry (SC-ZRA) as an innovative method for studying and monitoring MIC in oil and gas …
-
Hydrostatic Performance Of Reinforced Concrete Pipe For Infiltration
… a primary option for sewer systems, existing hydrostatic testing methods conducted by manufacturers to measure internal pipe pressure, as required by specifications, do not reflect in-situ external hydrostatic conditions. This thesis records the development of a novel testing method to …
-
TIME-TEMPERATURE DEPENDENT CHARACTERIZATION OF POLYMERS FOR ACCURATE PREDICTION OF STRESSES IN ELECTRONIC PACKAGES
… subjected to constant uniaxial compression and hydrostatic pressure at various temperatures. Two major developments to accommodate the unique requirements of EMC testing include: (1) a large mold pressure for specimen fabrication; and (2) a high gas pressure for hydrostatic testing while …
-
MOLD PROCESS INDUCED RESIDUAL STRESS PREDICTION USING CURE EXTENT DEPENDENT VISCOELASTIC BEHAVIOR
… viscoelastic bulk modulus -K(t,T) of EMC using hydrostatic testing. The methodology is implemented with a unique test setup based on inert gas. The results of viscoelastic testing along with the shear modulus (G) and bulk modulus (K) master curves and temperature-dependent shift factors (a(T)) …
-
Stress- and strain-based reliability assessment of pipelines subjected to internal pressure and permanent ground movement
… related to the pipe design, pre-commission hydrostatic testing, and operation are studied. Specifically, both corrosion and crack defects are considered for pipeline integrity assessment based on different defect scenarios. The probabilities of failure (PoFs), are reported with respect to …
-
Investigation of Surface Crack Growth Behaviour Under Variable Pressure Fluctuations in Near-Neutral pH Environments
… financial and technical burdens of full-scale testing, a simple, yet effective test setup was implemented. A novel sample geometry possessing three surface cracks with their notches removed, dubbed the Surface Crack Tension (SCT) specimen, was used in combination with a simulated coating …
-
Cured-in-Place Pipe Pressure Liner Experimental Study
… determined. It also provides CIPP short-term hydrostatic burst response for a 150-mm and 200-mm I-Main composite pressure CIPP liner. It estimates the Pressure Rating (PR) using the well-established Hydrostatic Design Basis (HDB) design approach. For flat plate testing, 10,000-hour flexural …
-
Aplicação de técnicas eletroquímicas na determinação do potencial de corrosividade de ligas de alumínio em água produzida
The resistance of aluminum and their alloys, to the corrosion phenomenon, in aqueous solutions, is a result of the oxide layer formed. However, the corrosion process in the aluminum alloy is associated with the presence a second phase of particles or the presence of chloride ions which promote the …
-
Diseño y comparación de 3 sistemas de control para sistema automático de pruebas de hermeticidad de bombas sumergibles según norma ASME BPVC Sección VIII
El presente trabajo desarrolla un sistema automatizado de control de presión para pruebas hidrostáticas aplicadas a carcasas de bombas sumergibles, con el fin de reducir la variabilidad en los tiempos de verificación de hermeticidad observados en los métodos manuales tradicionales. El sistema …