Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 47 for “"Hypodermic needle"”.

  1. Fabrication, packaging, and application of micromachined hollow polymer needle arrays

    Micromachined needles have been shown to successfully transport biological molecules into the body with minimal invasiveness and pain, following the insertion of needles into the skin. The aim of this research is to demonstrate that micromachined hollow polymer needle arrays fabricated using UV …

    gatech Repository record for Fabrication, packaging, and application of micromachined hollow polymer needle arrays (opens in a new tab)

  2. Development of a smart needle integrated with an impedance sensor to determine needle to nerve proximity for nerve blocking (anaesthetic) procedures

    … integration of a two-electrode system to a hypodermic needle and therefore fabrication of a smart needle. The concept was conceived with the intention of addressing a currently unmet clinical need for a regional anaesthetic procedure, ultrasound guided peripheral nerve block (USgPNB). The …

    cork Repository record for Development of a smart needle integrated with an impedance sensor to determine needle to nerve proximity for nerve blocking (anaesthetic) procedures (opens in a new tab)

  3. Thermostabilization of influenza vaccine in microneedle patches

    Vaccine delivery to the skin via microneedles confers several advantages over the traditional hypodermic needle and syringe. This work focuses on developing microneedles as a thermostable delivery method for the influenza vaccine that can be completely removed from the cold-chain, thus minimizing …

    gatech Repository record for Thermostabilization of influenza vaccine in microneedle patches (opens in a new tab)

  4. Formulation, Characterization, and in vivo Immunogenicity Evaluation of Heat-Stabilized Dissolvable Polymeric Microneedles

    … personnel to administer parental vaccines, and needle phobia. As an alternative, dissolvable microneedles have recently been studied for their simple and painless application. In this thesis, I present a novel manufacturing process for polymer-based dissolvable microneedles, loaded with …

    unm Repository record for Formulation, Characterization, and in vivo Immunogenicity Evaluation of Heat-Stabilized Dissolvable Polymeric Microneedles (opens in a new tab)

  5. FABRICATION OF DISSOLVING MICRONEEDLES FOR MRNA DELIVERY

    … suffers from a lack of options for delivery. The hypodermic needle is the current standard bearer but often elicits aversion from patients, which could lead to poor compliance. In this study, we explore the use of dissolving microneedles (DMN) for the transcutaneous delivery of naked mRNA …

    nus Repository record for FABRICATION OF DISSOLVING MICRONEEDLES FOR MRNA DELIVERY (opens in a new tab) Download file for FABRICATION OF DISSOLVING MICRONEEDLES FOR MRNA DELIVERY (opens in a new tab)

  6. At the margins: Uyghur ethnicity and the friend/enemy dialectic in Xinjiang.

    … PRC and extending to the ―7.5‖ race riots and hypodermic needle attacks in the summer of 2009 the thesis contends that the categories of ethnicity have been at the heart of the elimination of the enemy in China and can be linked directly to many of the Chinese state‘s colonial practices.

    uvic Repository record for At the margins: Uyghur ethnicity and the friend/enemy dialectic in Xinjiang. (opens in a new tab)

  7. Intensity distribution in cylindrical and bowl shaped transducers and sono-dialysis of a caustic solution

    … tube voltmeter. This element was cemented in a hypodermic needle in turn was held in a lucite rod (1/2 inch in diameter and five inches in length) which served as a holder. This arrangement was used to probe the sonic fields of cylindrical and bowl shaped transducers.

    vt Repository record for Intensity distribution in cylindrical and bowl shaped transducers and sono-dialysis of a caustic solution (opens in a new tab)

  8. Development of 3D Printed and 3D Metal-Based Micro/Nanofabricated, and Nano-Functionalized, Microelectrode Array (MEA) Biosensors For Flexible, Conformable, and In Vitro Applications

    … the final 3D conformation by a custom fabricated Hypodermic Needle Array (Hypo-Rig). The 3D metal MEAs were packaged on multiple substrates, and a 3D insulation layer was defined to fabricate microelectrodes that were subsequently characterized mechanically and electrically.

    ucf Repository record for Development of 3D Printed and 3D Metal-Based Micro/Nanofabricated, and Nano-Functionalized, Microelectrode Array (MEA) Biosensors For Flexible, Conformable, and In Vitro Applications (opens in a new tab)

  9. Understanding drug dispersion patterns in human muscle tissue using simulation and experimental validation

    Hypodermic needle and syringe remain the vanguard for drug delivery, yet drug dispersion into different types, especially muscle, remains poorly understood. Performing ex-vivo and in-vivo studies are expensive which require a lot of materials and generates more biological hazardous waste. In …

    ttu Repository record for Understanding drug dispersion patterns in human muscle tissue using simulation and experimental validation (opens in a new tab)

  10. Non-Invasive, Multi-Modal Sensing Techniques for Detecting Infiltration During Intravenous Therapy

    … inadvertently into soft tissue surrounding a hypodermic needle site. This occurrence affects over 10% of patients in hospitals worldwide, and can lead to severe tissue damage if not treated immediately. However, the methods currently used by medical staff to detect an infiltration are …

    gatech Repository record for Non-Invasive, Multi-Modal Sensing Techniques for Detecting Infiltration During Intravenous Therapy (opens in a new tab)

  11. Development of core-shell nanostructured corrosion-resistant photoanodes for hydrogen generation

    … layered photoanodes were fabricated using a needle-to-plane electrode geometry. A layer of low-bandgap TiSi2 particles was deposited onto a titanium substrate followed by a second layer of TiO2 nanoparticles. The structure was then sintered at 600◦C for 3 hours to promote TiSi2 interparticle …

    bu Repository record for Development of core-shell nanostructured corrosion-resistant photoanodes for hydrogen generation (opens in a new tab)

  12. A defect detection algorithm for sequential and parallel computers

    … purposes, an original image of a centered hypodermic needle is compared to a second image of the needle in a different position. This algorithm will determine if both images contain the same object regardless of position. The second application detects changes(defects) in the needle …

    njit Repository record for A defect detection algorithm for sequential and parallel computers (opens in a new tab)

  13. Coordinated regulation of the flagellar, Salmonella pathogenicity island 1, and the type I fimbriae gene networks in Salmonella typhimurium

    … reaching the site of infection, it assembles a hypodermic needle on its surface using which it injects proteins into host cells. These proteins cause a change in the host-cell shape leading to internalization of the bacterium. If the bacterium fails to get internalized, it assembles finger-like …

    uiuc Repository record for Coordinated regulation of the flagellar, Salmonella pathogenicity island 1, and the type I fimbriae gene networks in Salmonella typhimurium (opens in a new tab)

  14. Characterization of plastic hypodermic needles

    Significant potential for plastic hypodermic needles exists as an alternative to current steel needles, especially in developing regions where proper needle disposal is problematic. Needle reuse causes tens of millions of hepatitis and HIV infections each year. Plastic needles may reduce …

    gatech Repository record for Characterization of plastic hypodermic needles (opens in a new tab)

  15. Thermo-Mechanical Behavior of Polymer Composites Exposed to Fire

    … (VARTM) is developed to manufacture PMCs with a hypodermic needle inserted for internal pressure measurement. One-sided heating tests are conducted on the glass/vinyl ester composites to measure the pressure at different locations through thickness during the decomposition process. The model is …

    vt Repository record for Thermo-Mechanical Behavior of Polymer Composites Exposed to Fire (opens in a new tab)

  16. Humidity preference and temperature tolerances of four species of fire ants (Hymenoptera: Formicidae: Solenopsis)

    … RH). Supercooling points were determined with a hypodermic needle microprobe and tel-etherraometer- The mean supercooling points for the ants were -6.7° C for S. aurea, -8.6• C for S. geminata, -8.3• C for S. invicta, and -7.0° C for S. xyloni: Solenopsis aurea and S- xyloni ware not …

    ttu Repository record for Humidity preference and temperature tolerances of four species of fire ants (Hymenoptera: Formicidae: Solenopsis) (opens in a new tab)

  17. Laser-based optical fiber absorbance probes for clinical analyses

    … of a single optical fiber encased in a blunt hypodermic needle with a highly reflective surface affixed at the end of the needle, thus forming a microabsorbance cell. The blunt needle is inserted inside a larger needle to form a cannula. By aspirating through the inner needle, biological fluid …

    ut-knoxville Repository record for Laser-based optical fiber absorbance probes for clinical analyses (opens in a new tab)

Page 1 of 3