Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 20 of 31 for “"I-V measurement"”
-
A study of charge trapping effect on high-k device characteristics and reliability; and its implication on circuit operation
… charging behavior in high-k devices, pulsed I-V measurement has been proposed. Using pulsed I-V measurement technique, the effects of interface treatment and dielectric stacks on transient characteristics of high-k transistors were studied. The results based on varying pulse frequency and …
-
Device applications of transition metal oxide thin films
… diffraction (XRD), and current-voltage (I-V) measurement.
-
ANALYSIS OF RADIATION EFFECTS ON GALLIUM NITRIDE ZIRCONIUM OXIDE METAL OXIDE SEMICONDUCTOR CAPACITORS
… (C-F), and Current-Voltage (I-V) measurement prior to and post exposure. Each reticle's C-V measurement and its hysteresis was then compared pre- and post-exposure for effects. Testing concluded with a time-dependent dielectric breakdown analysis. Results show that radiation …
-
Design, Fabrication and Characterization of Thin-Film M-I-M Diodes for Rectenna Array
… non-linear and asymmetric. Based on the I-V measurement, the logarithmic derivative of I vs. V was plotted and the tunneling behavior was also observed.
-
THE GROWTH OF SNSBSE2 CRYSTAL AND THE INVESTIGATION OF PHYSICAL PROPERTIES OF THERMALLY EVAPORATED SNSBSE2 THIN FILMS
… Microscopy, X-Ray Diffrac tion and Raman measurement were performed to investigate the structural analysis. Also, spectroscopic ellipsometry measurement carried out to obtain index of refrac tion, extinction coefficient and optical band gap for optical characterization. The I-V measurement …
-
Tunable bandwidth quantum well infrared photo detector (TB-QWIP)
… of the TB-QWIP is based on absorption measurement with Fourier Transform Infra Red (FTIR) spectroscopy, current versus applied voltage (I-V) measurement with a semiconductor parameter analyzer, and photocurrent spectroscopy. The measured IR absorption peaks found at room temperature 8.8 …
-
A Gas Sensor Based on Inelastic Electron Tunneling Spectroscopy for Electronic Nose Applications
… amplifier was found to be superior for IETS measurements versus an analog lock-I amplifier and I-V measurement system. Future work should include fabricating devices without breaking the vacuum to reduce impurities in the junction, thereby improving device yield, and stability. It should also …
-
Analysis of Photodetector Based on Zinc Oxide and Cesium Lead Bromide Heterostructure with Interdigital Metallization
… to be 3.8 × 1011 cm / Hz2 W from the I-V measurement. Under 10 µW light illumination the device showed good photo responsivity of 14.99 A/W. The fabricated photo detectors demonstrated excellent stability. This project explains that ZnO/CsPbBr3 hetero structure is a promising candidate for …
-
AIN thick films for power electronic device applications
… diode. The ideality factor from the I-V measurement is 1.39. From the Hall measurements, the mobility of 3490cm<sup>2</sup>/V.s at the doping level of 2 x 10<sup>17</sup>cm<sup>-3</sup> for GaAs films on AlN has been shown. For thermal properties of AlN films, thermal conductivity was …
-
MBE Growth and Characterization of Graphene on Well-Defined Cobalt Oxide Surfaces: Graphene Spintronics without Spin Injection
… the films are stoichiometric. Electrical I-V measurement of the Co3O4(111) show characteristic hysteresis indicative of resistive switching and thus suitable for advanced device applications. In addition, the growth of Co0.5Fe0.5O(111) was also achieved by MBE and these films were observed to …
-
CHARACTERISATIION OF DEFECTS IN TANTALUM PENTOXIDE FILMS BY THERMALLY STIMULATED CURRENT
… for leakage current in Ta2O5 films. I-V measurement was done on all the samples to measure the leakage current which is an important criterion for the quality of the tantalum pentoxide film. Ta2O5 films deposited on p+ -Si and n+ -Si substrates were subjected to high temperature dry …
-
Simulation and Fabrication of All Oxide-Based ITO/TiO2/CuO/Au Heterostructure for Solar Cell Applications
… scanning electron microscopy, and electrical measurements i.e., diode characteristics test with light and without light. The rutile phase of TiO2 was successfully grown on glass, quartz, and ITO to find the best growth parameters for TiO2 film. Same experimental works were carried out for the …
-
Analysis and evaluation of HFO2 based resistive RAM devices for new generation non-volatile memories
… methods. Raman and X-Ray diffraction (XRD) measurements were conducted for investigating the structural properties and effects of crystallinity on the oxide material. By these measurements, the difference between crystalline and amorphous HfO2 was observed. Also, the monoclinic and …
-
Measuring Low Dimensional Schottky Barriers of Rare Earth Silicide-Silicon Interfaces
The focus of this study is the measurement of low dimensional Schottky barrier heights of metal silicide-silicon interfaces and the challenges of current-voltage (I/V) curve interpretation. Engineering the Schottky barrier to exploit the spin and charge of an electron and manipulate it through …
-
Research and development of CdS/CdTe solar cells incorporating ZnTe layers.
… (XRD) and photoelectrochemical (PEC) cell measurements. These techniques were used to study the optical, structural and electrical conductivity type of the electrodeposited layers respectively. After optimizing the layers using the above three techniques (optical absorption, XRD and PEC), …
-
Thin Film Metal-Insulator-Metal Tunnel Junctions For Millimeter Wave Detection
… surface wave loss. DC and millimeter wave measurements were carried out on the fabricated diodes to determine the device characteristics and performance. The current-voltage (I-V) measurements yielded current in the range of few µA with significant non-linearity and asymmetry. A maximum …
-
GeSn Light-Emitting Devices
… was studied using the current-voltage (I-V) measurement, electroluminescence (EL), as well as optical power. EL spectra of 6%, 8%, 9%, and 10% Sn LED was measured. Emission due to the direct band was observed. The wavelength of the EL spectrum peak of 2348 nm was achieved for measuring 10% Sn …
-
An investigation of a catalyst free PECVD nanocrystalline graphene/graphite on insulator
… spectroscopy and a simple four point probe measurements respectively.<br/>The electrical properties of the NCG films are performed using I-V measurement on a simple two terminal device with titanium/nickel (Ni/Ti) contacts. Transmission line method (TLM) structures with Ni/Ti probe pads are …
-
Current collapse and device degradation in AlGaN/GaN heterostructure field effect transistors
… penetration of the market. Calibration of I-V measurements of two devices is performed with high accuracy to provide a trustworthy starting point for modelling the phenomena of interest. Traditionally, in simulations of nitride based HEMTs, only direct piezoelectric effect is taken into account …
-
Graphene and III-V channel metal-oxide-semiconductor field-effect devices for post-Si CMOS applications
… device performance. In particular, a pulsed I-V measurement technique was used to assess the impact of fast and slow transient charging effects on various III-V transistors with ALD-deposited Al2O3 gate dielectric. The charge pumping technique was also utilized to determine the density of …
Page 1 of 2