Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 56 for “"I-girders"”.
-
Anchorage of stirrups in prestressed concrete I-girders
The current research investigates the performance of commonly-used non-code-compliant stirrup detailing in concrete I-girder bridges, specifically when the lower hooks on the stirrups are oriented parallel to the longitudinal prestressing strands and are not bent around any longitudinal bars. Such …
-
Stabilizing techniques for curved steel I-girders during construction
… arise due to the complex geometry of curved I-girders. To prevent excessive rotation in erected girders, three points of vertical support are often provided. Two of these points usually consist of permanent supports in the form of bridge piers or abutments. The third point of support may …
-
Predicting the behavior of horizontally curved I-girders during construction
… that predicts the behavior of curved I-girders during lifting. The derivation of the equations necessary to accomplish these calculations and the implementation are described in this dissertation. UT Bridge is a PC-based, user-friendly, 3-D finite element program for I-girder bridges. …
-
Pier moment-rotation behavior of high performance steel HPS70W I-girders
… noncompact high performance steel HPS70W I-shape girders in the context of examining two restrictions for inelastic design of steel bridge girders in the current edition of the AASHTO LRFD bridge code (AASHTO, 1998 and interim 2001). The first restriction is that inelastic design involving the …
-
Transverse Stiffener Requirements in Straight and Horizontally Curved Steel I-Girders
… research studies have confirmed that curved I-girders are capable of developing substantial shear postbuckling resistance due to tension field action and have demonstrated that the AASHTO LRFD equations for the tension field resistance in straight I-girders may be applied to curved I-girders …
-
Shear strengthening of precast prestressed I-girders with FRP or SMA
Een van de meest gebruikte types ligger in voorgespannen beton heeft een I-vormige dwarsdoorsnede, die in verschillende afmetingen wordt toegepast in diverse constructies, waaronder bruggen. Bij een verlenging van de levensduur van dergelijke I-liggers kan dwarskrachtversterking een belangrijk …
-
Evaluation of the ductility of composite steel I-girders in positive bending
Current AASHTO bridge specifications limit the allowable maximum strength of simple spans and positive bending regions with adjacent compact pier sections to a value between the full plastic moment and the hypothetical yield moment of the cross section. The equation used for this strength …
-
Characterization and Modeling of Bond-Loss Behavior in Pretensioned Concrete I-Girders
… in load tests of precast-pretensioned concrete I-girders. This type of failure is associated with shear cracking near the support that interrupts anchorage of the strands, leading to loss of bond and slipping of the strands relative to the concrete. It has been experimentally demonstrated that …
-
Laser scan point cloud processing for displacement measurements of damaged steel I-girders
Submission original under an indefinite embargo labeled 'Open Access'. The submission was exported from vireo on 2024-09-16 without embargo terms
-
Rotation compatibility approach to moment redistribution for design and rating of steel I -girders
… can be obtained by: (1) limiting the range of girders for which moment redistribution is permissible to relatively compact members and (2) limiting the amount of moment that may be redistributed. Furthermore, the restriction of these procedures to relatively compact members has limited the …
-
Development of end-region cracks in pretensioned concrete I-girders employing 0.7-in. diameter strands
… an occurrence that is common in pretensioned girders, regardless of strand size. These cracks tend to grow in width, length, and number over time due to time-dependent effects such as shrinkage or creep. Additionally, the cracks tend to close under an applied load when placed in a …
-
End-region behavior of precast, prestressed concrete I-girders employing 0.7-inch diameter prestressing strands
Pretensioned concrete girders are currently fabricated using 0.5- or 0.6-in. diameter prestressing strands. In recent years, however, it has become of interest to employ larger-diameter 0.7-in. diameter strands to reduce the number of strands and improve the efficiency of pretensioned concrete …
-
A Compilation of Research on Seismic Vulnerability of Curved Bridges Using Straight Prestressed Concrete I-girders
… use straight pre-stressed-precast concrete girders with a curved cast-in-place deck on top. The result is that beams are chorded along the curve of the deck, supported on each end by either an abutment or bent. Diaphragms are cast-in-place over bent supports between girder ends to create …
-
Experimental and Analytical Investigations of Doubly Symmetric Built-Up I-Girders with Large Moment Gradient Factors
… the flexural resistance of certain built-up I-girders. The largest reductions were observed in I-girders subjected to reverse curvature bending that have unstiffened webs, a large web slenderness ratio, and a high moment gradient factor resulting in a high shear-to-moment ratio. To further …
-
Performance of precast, prestressed concrete I-girders employing 0.7-in. diameter prestressing strands under shear-critical loading conditions
… might impact the shear strength of pretensioned girders due to the possibility of atypical failure modes that are not considered in current design provisions. An experimental program was conducted to study the effects of using 0.7-in. prestressing strands on the performance of precast, …
-
Computational modeling of prestress transfer, end-region cracks and shear behavior in prestressed concrete I-girders employing large-diameter strands
Prestressed concrete girders are commonly fabricated with 0.5-in. (12.7-mm) or 0.6-in. (15.2-mm) diameter prestressing strands. Recent interest in the use of larger (0.7-in. (17.8-mm) diameter) strands has been driven by potential benefits associated with reduction of the required number of strands …
-
Stability Analysis of Single and Double Steel Girders during Construction
<p>Built-up steel I-girders are very commonly used in bridge construction. Their spans are typically very long, and they are susceptible to lateral torsional buckling if not enough lateral support is provided. This thesis includes guidelines for preventing lateral torsional buckling of steel …
-
Seismic performance of an I-girder to inverted-T bent cap bridge connection
… that the connection between the precast I-girders and the inverted-T bent cap will degrade in a seismic event and shall therefore be designed as a pinned connection, making the precast girder option for seismic bridges inefficient. A prototype I-girder to inverted-T bent cap bridge and a …
-
Flange Buckling Behavior of Stainless Steel Girders with Trapezoidally Corrugated Webs - A parametric numerical study
… of a flat web with a corrugated one in steel girders is a way of increasing the shear buckling capacity, without the need of additional vertical stiffen ers. But, except for that, the corrugation of the web changes the bending behavior, more specifically the normal stress buckling behavior of …
-
An Experimental Investigation of the Flexural Resistance of Horizontally Curved Steel I-Girder Systems
… curvature on the structural performance of I-girders subject to moment and shear, to investigate moment/shear interaction, and to assess the behavior and ultimate capacity of a composite bridge. The experiments that are the focus of this dissertation are the component tests designed to …