Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 33 for “"ICCD camera"”.
-
Novel designs, materials and techniques in plasma bipolar junction transistor (PBJT) fabrication and testing
… PI-MAX 3 intensified charge-coupled device (ICCD) camera. As a further improvement on the PBJT design, fabrication using a novel laterally-doped configuration is underway and initial work in making this device has been illustrated. Finally, the fabrication of PBJTs on a silicon carbide …
-
Separation Control using Plasma Actuators: Experimental Studies of Plasma Actuator Performance
… compared to the other factors studied. ICCD camera visualization studies of the discharge indicated that the degree of discharge asymmetry between the two current half cycles is linearly related to the thrust. A simple model was used to explore the relationships between the applied …
-
Spatio-temporally Resolved Magnetic Field Measurements in the ZaP-HD Flow Z-Pinch Device Using Zeeman Splitting
… using a fast-framing ultra high-speed camera are taken and show general agreement with measurements taken by a single-frame ICCD camera.
-
Characterization of a piezoelectric transformer plasma source
… and imaging with an optical spectrometer and an ICCD camera.
-
Spectroscopic investigation of plasmas in liquids
… unpredictable behaviour. Imaging with an ICCD camera revealed discharge dynamic, microbubble formation, and arc-phase emissions. Optical spectroscopy confirmed the presence of hydrogen and oxygen atoms across all discharges, indicated by H, H, and O I 777 nm spectral lines, with black body …
-
A spectroscopic study on the detection of carbon monoxide for solar fuel production
… frequency doubling to generate 230 nm. A gated ICCD camera is used to detect emission (450 nm-750 nm) in the Ångström band ( ). Measurements in a reference cell filled with pure CO show an optimal excitation wavelength of 230.015 nm, while good signal-to-noise ratio spectra can be obtained at …
-
Fast Neutron & Gamma-Ray Scintillation and Broadband Photoluminescence from Gallium Nitride & Gallium Oxide: Developing Radiation-Hard Diagnostic Platforms
… 400 MeV. A Pi-Max 4 fast-gated Intensified CCD (ICCD) camera captured the transient scintillation responses for both materials, revealing fast rise and energy-dependent scintillation intensities. By quantifying neutron spectral flux using a fission chamber with U-238 fission foil, we analyzed the …
-
An experimental apparatus and diagnostics for the study of vacuum surface flashover
… using an intensified charge-coupled device (ICCD) camera. Observations have shown that early light emission does originate near the anode-vacuum-insulator junction due to mechanisms that agree with the Anderson model of anode-initiated flashover. Post-test imaging also revealed dendrite …
-
Magnetic field optimization for high power impulse magnetron sputtering
… magnet pack with superior uniformity. A gated ICCD camera was used to investigate the moving localized ""ionization zones"" in the TriPack. Langmuir probe and ion fraction measurements were also carried out to understand the behavior of high current pulsed discharge in this new magnetic field …
-
Conductor to insulator transition and insulator to conductor transition, studied by gas discharges and break junctions
… by using an imaging technique utilizing an ICCD camera. The starting images reveal that the emission pattern exhibits many, point-like, intense spikes, which implies that the ionization process starts at many places at once, in contrast to the finger-like streamers found in …
-
Development of electrode manipulated close-packed microplasma jet arrays in a transparent polymer
… arrays. Examination of He microplasma with an ICCD camera reveals considerable structure on the spatial emission profiles for the jets. Individual microchannel control has been developed in an array device. For glow regions of the microplasma, the peak intensity is produced 88-112 μm from the …
-
Laser induced incandescence imaging for the investigation of soot formation in laminar flames
… to measure the LII signal using a Nd:YAG laser, ICCD camera and flat flame burner and calibrated along with another optical technique known as extinction. This allowed for the soot volume fraction to be calibrated and measured and this gives the standard case for calibrating other measurements in …
-
Formation of RDX nanoparticles by rapid expansion of supercritical solution : in situ characterization by laser scattering
… light scattering imaging technique using gated ICCD camera. The sensitivity was determined using Rayleigh scattering from air as well as light scattering from standard polystyrene spheres. The size distribution functions of the particles formed in the RESS jet were determined using the …
-
Fluorescence enhanced optical tomography on breast phantoms with measurements using a gain modulated intensified CCD imaging system
… A novel intensified charge-coupled device (ICCD) imaging system has been developed to perform 3-D fluorescence tomographic imaging in the frequency-domain using near-infrared contrast agents. This study is unique since it (i) employs a large tissue-mimicking phantom (~1087 cc), which is …
-
Subunits of highly fluorescent protein R-phycoerythrin as probes for cell imaging and single-molecule detection
… and an intensified charge-coupled device (ICCD) camera recorded simultaneously the zero order and the first order spectrum for each cell. Demonstrated method could have a higher throughput, better sensitivity, and better spectral resolution compared to spectral flow cytometry.</p>
-
LED-based thermographic phosphorescence imaging in a diesel engine environment
… made use of a high-power LED system and ICCD camera, which offers practical advantages such as lower cost and reduced safety concerns in comparison to laser-based phosphorescence diagnostics. The study first investigated how phosphorescence signals were influenced by the coating …
-
Dynamics of Non-Thermal Plasma Jets Under Variable Pressure
… studied by means of high speed imaging using an ICCD camera, and emission spectroscopy using a high resolution spectrometer. Through these characterizations it is reported that the results support the photoionization theory for plasma bullet propagation as plasma bullets only propagate along the …
-
Near infrared optical lymphography for cancer diagnostics
… intensified charge-coupled device (ICCD) camera, which captures low-intensity, near-infrared, and frequency-modulated photons. A four-fold âÂÂoptical lymphographyâ study was conducted to (1) examine fluorescence depth penetration and ICCD system accuracy at clinically …
-
Characterizations of Atmospheric Pressure Low Temperature Plasma Jets and Their Applications
… bullet are investigated by means of a high-speed ICCD camera. A plasma bullet propagation model based on the streamer theory is confirmed with adequate explanations. It is also found that a secondary discharge, ignited by the charge accumulation on the dielectric electrode surfaces at the end of …
-
Streamer development and propagation through a coaxial reactor using a sub-nanosecond rise-time pulse source
… rate and gas flow is investigated using an ICCD camera. An automation system is designed to control the position of the camera and pulse source and it processes the data generated by the camera and oscilloscope without human interference. It is found that generally the maximum streamer …
Page 1 of 2