Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 2,962 for “"ICP MS"”

  1. Developments in ICP-MS: electrochemically modulated liquid chromatography for the clean-up of ICP-MS blanks and reduction of matrix effects by flow injection ICP-MS

    … of inductively coupled plasma mass spectrometry (ICP-MS). ICP-MS is a powerful technique for trace metal analysis in samples of many types, but like any technique has certain strengths and weakness. Attempts are made to improve upon those strengths and to overcome certain weaknesses.;One standout …

    iastate Repository record for Developments in ICP-MS: electrochemically modulated liquid chromatography for the clean-up of ICP-MS blanks and reduction of matrix effects by flow injection ICP-MS (opens in a new tab)

  2. Fundamental And Applied Measurements In ICP-MS

    Fundamental and applied aspects of ICP-MS have been investigated to gain an increased understanding of the technique and improve on its analytical capabilities. Dissociation temperatures of polyatomic ions were calculated using a double-focusing sector instrument, to obtain more reliable mass …

    plymouth Repository record for Fundamental And Applied Measurements In ICP-MS (opens in a new tab)

  3. Fundamental Studies Of Interferences In ICP - MS

    … for diatomic ions which cause interferences in ICP-MS, was compiled. The equilibration temperature, calculated using the different methods and using various diatomic ions as the thermometric probes, was between c.a. 400 - 10,000 K in the central channel, and between c.a. 600 - 16,000 K when the …

    plymouth Repository record for Fundamental Studies Of Interferences In ICP - MS (opens in a new tab)

  4. Ion Transport in a Commercial ICP-MS

    … an inductively coupled plasma mass spectrometer, ICP-MS, depends on the instrument's ability to transport sample ions through the vacuum interface and focus the ions into a well-defined beam that will eventually reach the mass analyzer. In this study two main experiments were performed on the …

    byu Repository record for Ion Transport in a Commercial ICP-MS (opens in a new tab)

  5. Détection et caractérisation des nanoparticules de dioxyde de titane dans les aliments par AF4-ICP-MS et Sp-ICP-MS

    … en deux axes. Le développement de la méthode AF4-ICP-MS (I) au sein de la Plateforme Nano-Sécurité du CEA de Grenoble et le développement de la méthode Sp-ICP-MS (II) au sein du Laboratoire de la Sécurité Aliments de l’Anses à Maisons-Alfort.Pour le premier axe, les interactions électrostatiques …

    star-france Repository record for Détection et caractérisation des nanoparticules de dioxyde de titane dans les aliments par AF4-ICP-MS et Sp-ICP-MS (opens in a new tab)

  6. Arsenic speciation in fish by HPLC-ICP-MS

    … inductively coupled plasma mass spectrometry (ICP-MS) detection. Total As concentrations were found by ICP-MS using samples digested by nitric acid-hydrogen peroxide solution using microwave oven digestion; the results were in the range of 1.15-12.6 µg/g. Separation of organic arsenicals, …

    metu Repository record for Arsenic speciation in fish by HPLC-ICP-MS (opens in a new tab)

  7. Multielement Profiling by ICP-MS in Food Traceability

    … based on ultra-trace triple quadrupole ICP-MS. In this thesis, a brand new ICP-MS facility for ultra-trace elemental analysis was tested and set into operational conditions, including the optimization of several analytical methods for the determination of trace and ultra-trace elements …

    bologna Repository record for Multielement Profiling by ICP-MS in Food Traceability (opens in a new tab)

  8. Detección de metales pesados en pesticidas por ICP-MS

    … En este sentido la Espectrometría de Masas (MS) en conjunto con Plasma Acoplado Inductivamente (ICP-MS) se ofrece como una técnica atractiva para el análisis de estos metales debido a su alta sensibilidad, buena linealidad y, en especial, a su versatilidad para diferentes tipos de matrices …

    pucp-peru-2 Repository record for Detección de metales pesados en pesticidas por ICP-MS (opens in a new tab) Restricted access

  9. Fundamental studies of mixed gas plasmas in ICP-MS

    … using both wet and dry sample introduction systems. Simplex optimization procedures have been used throughout. The addition of nitrogen to all three argon gas flows of the ICP was evaluated, and the instrumental operating conditions were optimized to allow for the maximum removal of the ArCl+ …

    plymouth Repository record for Fundamental studies of mixed gas plasmas in ICP-MS (opens in a new tab)

  10. Flow injection methods of sample introduction for ICP-MS

    … inductively coupled plasma mass spectrometry (ICP-MS). A comprehensive introduction to ICP-MS and the various sample introduction methods which have been applied for the technique is presented in Chapter 1. The advantages and disdvantages of the different sample introduction procedures are also …

    hull Repository record for Flow injection methods of sample introduction for ICP-MS (opens in a new tab)

  11. Lu-Hf em zircão por LA-MC-ICP-MS

    … nas análises in situ em zircão por LA-ICP-MS. O interesse na aplicação desta metodologia, quando se dispõe de um sistema como o LA-ICP-MS, deve ser consignado à relativa simplicidade, sensibilidade e rapidez da análise. A alta concentração e a baixa mobilidade do Hf no zircão propiciam …

    brazil-ufrgs Repository record for Lu-Hf em zircão por LA-MC-ICP-MS (opens in a new tab)

  12. Environmental speciation of tin and lead by HPLC-ICP-MS

    … inductively coupled plasma-mass spectrometer (ICP-MS) for this application has been modified to yield limits of detection of 0.44,0.26,1.4 and 0.23 ng. g-' as Sri for TBT, TPhT, DBT and MBT respectively. Different extraction procedures have been tested for the determination of organotin species …

    plymouth Repository record for Environmental speciation of tin and lead by HPLC-ICP-MS (opens in a new tab)

  13. Determination of actinide elements in environmental samples by ICP-MS

    … inductively coupled plasma mass spectrometry (ICP-MS). Initial applications utilised a commercially available resin, namely TRU-Spec resin, for efficient removal of the matrix prior to elution of uranium and thorium analytes. Comparative analyses of reference materials and natural water samples …

    plymouth Repository record for Determination of actinide elements in environmental samples by ICP-MS (opens in a new tab)

  14. Strategies for halogen determination and isotopic analysis via ICP-MS

    … inductief gekoppeld plasma massaspectrometrie (ICP-MS) en voor de meting van isotopen verhoudingen gebruikmakend van multicollector (MC) ICP-MS. Vier methodes voor directe vastestofanalyse (SS) door middel van ICP-MS – drie met behulp van elektrothermische vervluchtiging (ETV) en één middels …

    ghent Repository record for Strategies for halogen determination and isotopic analysis via ICP-MS (opens in a new tab)

  15. Speciation studies using hplc-icp-ms and hplc-es-ms

    … selenium species is very important in terms of both nutrition and toxicity. Bioavailability of selenium species for human body is different from each other. Hence, speciation of selenium is more important than total selenium determination. In the selenium speciation study, chicken breast …

    metu Repository record for Speciation studies using hplc-icp-ms and hplc-es-ms (opens in a new tab)

  16. Analysis of trace elements in Irish freshwater by ICP-MS

    … Inductively Coupled Plasma - Mass Spectroscopy (ICP-MS), a method that allows for rapid and sensitive multi-element measurements. The purpose o f the analyses was primarily to increase knowledge of Irish surface water chemistry. It was also hoped that the work would assist in the understanding o …

    dcu Repository record for Analysis of trace elements in Irish freshwater by ICP-MS (opens in a new tab)

  17. ⁹⁹Tc bioassay by inductively coupled plasma mass spectrometry (ICP-MS)

    … by inductively coupled plasma mass spectrometry (ICP-MS) has been developed. Historically, <sup>99</sup>Tc analysis was based on the radiometric detection of the 293 keV E<sub>Max</sub>. beta decay product by liquid scintillation or gas flow proportional counting. In a urine matrix, the analysis …

    utk-theses Repository record for ⁹⁹Tc bioassay by inductively coupled plasma mass spectrometry (ICP-MS) (opens in a new tab)

Page 1 of 149