Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 1792 for “"ICP-MS"”.

  1. Developments in ICP-MS: electrochemically modulated liquid chromatography for the clean-up of ICP-MS blanks and reduction of matrix effects by flow injection ICP-MS

    … of inductively coupled plasma mass spectrometry (ICP-MS). ICP-MS is a powerful technique for trace metal analysis in samples of many types, but like any technique has certain strengths and weakness. Attempts are made to improve upon those strengths and to overcome certain weaknesses.;One standout …

    iastate Repository record for Developments in ICP-MS: electrochemically modulated liquid chromatography for the clean-up of ICP-MS blanks and reduction of matrix effects by flow injection ICP-MS (opens in a new tab)

  2. Fundamental And Applied Measurements In ICP-MS

    Fundamental and applied aspects of ICP-MS have been investigated to gain an increased understanding of the technique and improve on its analytical capabilities. Dissociation temperatures of polyatomic ions were calculated using a double-focusing sector instrument, to obtain more reliable mass …

    plymouth Repository record for Fundamental And Applied Measurements In ICP-MS (opens in a new tab)

  3. Fundamental Studies Of Interferences In ICP - MS

    … for diatomic ions which cause interferences in ICP-MS, was compiled. The equilibration temperature, calculated using the different methods and using various diatomic ions as the thermometric probes, was between c.a. 400 - 10,000 K in the central channel, and between c.a. 600 - 16,000 K when the …

    plymouth Repository record for Fundamental Studies Of Interferences In ICP - MS (opens in a new tab)

  4. Ion Transport in a Commercial ICP-MS

    … an inductively coupled plasma mass spectrometer, ICP-MS, depends on the instrument's ability to transport sample ions through the vacuum interface and focus the ions into a well-defined beam that will eventually reach the mass analyzer. In this study two main experiments were performed on the …

    byu Repository record for Ion Transport in a Commercial ICP-MS (opens in a new tab) Download PDF for Ion Transport in a Commercial ICP-MS (opens in a new tab)

  5. Fundamental studies of mixed gas plasmas in ICP-MS

    … using both wet and dry sample introduction systems. Simplex optimization procedures have been used throughout. The addition of nitrogen to all three argon gas flows of the ICP was evaluated, and the instrumental operating conditions were optimized to allow for the maximum removal of the ArCl+ …

    plymouth Repository record for Fundamental studies of mixed gas plasmas in ICP-MS (opens in a new tab)

  6. Lu-Hf em zircão por LA-MC-ICP-MS

    … nas análises in situ em zircão por LA-ICP-MS. O interesse na aplicação desta metodologia, quando se dispõe de um sistema como o LA-ICP-MS, deve ser consignado à relativa simplicidade, sensibilidade e rapidez da análise. A alta concentração e a baixa mobilidade do Hf no zircão propiciam …

    brazil-ufrgs Repository record for Lu-Hf em zircão por LA-MC-ICP-MS (opens in a new tab)

  7. ⁹⁹Tc bioassay by inductively coupled plasma mass spectrometry (ICP-MS)

    … by inductively coupled plasma mass spectrometry (ICP-MS) has been developed. Historically, <sup>99</sup>Tc analysis was based on the radiometric detection of the 293 keV E<sub>Max</sub>. beta decay product by liquid scintillation or gas flow proportional counting. In a urine matrix, the analysis …

    utk-theses Repository record for ⁹⁹Tc bioassay by inductively coupled plasma mass spectrometry (ICP-MS) (opens in a new tab)

  8. Analysis of trace elements in Irish freshwater by ICP-MS

    … Inductively Coupled Plasma - Mass Spectroscopy (ICP-MS), a method that allows for rapid and sensitive multi-element measurements. The purpose o f the analyses was primarily to increase knowledge of Irish surface water chemistry. It was also hoped that the work would assist in the understanding o …

    dcu Download PDF for Analysis of trace elements in Irish freshwater by ICP-MS (opens in a new tab)

  9. Determination of actinide elements in environmental samples by ICP-MS

    … inductively coupled plasma mass spectrometry (ICP-MS). Initial applications utilised a commercially available resin, namely TRU-Spec resin, for efficient removal of the matrix prior to elution of uranium and thorium analytes. Comparative analyses of reference materials and natural water samples …

    plymouth Repository record for Determination of actinide elements in environmental samples by ICP-MS (opens in a new tab)

  10. Environmental speciation of tin and lead by HPLC-ICP-MS

    … inductively coupled plasma-mass spectrometer (ICP-MS) for this application has been modified to yield limits of detection of 0.44,0.26,1.4 and 0.23 ng. g-' as Sri for TBT, TPhT, DBT and MBT respectively. Different extraction procedures have been tested for the determination of organotin species …

    plymouth Repository record for Environmental speciation of tin and lead by HPLC-ICP-MS (opens in a new tab)

  11. Strategies for halogen determination and isotopic analysis via ICP-MS

    … inductief gekoppeld plasma massaspectrometrie (ICP-MS) en voor de meting van isotopen verhoudingen gebruikmakend van multicollector (MC) ICP-MS. Vier methodes voor directe vastestofanalyse (SS) door middel van ICP-MS – drie met behulp van elektrothermische vervluchtiging (ETV) en één middels …

    ghent Repository record for Strategies for halogen determination and isotopic analysis via ICP-MS (opens in a new tab)

  12. Ablační komora pro kombinaci technik LIBS a LA-ICP-MS

    … vázaného plazmatu s laserovou ablací (LA-ICP-MS) jsou spektroskopické techniky, které při své analýze využívají pulzního laseru pro ablaci materiálu. Ačkoliv je LA-ICP-MS schopno dosáhnout mnohem nižšího detekčního limitu než LIBS, není schopno detekovat prvky organických sloučenin, …

    brno-tech Repository record for Ablační komora pro kombinaci technik LIBS a LA-ICP-MS (opens in a new tab)

  13. Assessing the capabilities of the ICP-MS/MS for radionuclide analysis

    <p class="MsoNormal">The development of robust and routine methods for radionuclide analysis using ICP-MS/MS systems has been investigated for application to nuclear decommissioning and waste characterisation, as well as applications to nuclear forensics and emergency response scenarios. The …

    soton Download PDF for Assessing the capabilities of the ICP-MS/MS for radionuclide analysis (opens in a new tab)

  14. The Determination Of Trace Metals In Sea Water Using ICP-MS

    Inductively coupled plasma-mass spectrometry (ICP-MS) offers exceptional sensitivity and multi-element capability for trace metal analysis but the formation of polyatomic ions (particularly below m/z = 80) can cause, serious interferences. Such species can be introduced via precursor atoms in …

    plymouth Repository record for The Determination Of Trace Metals In Sea Water Using ICP-MS (opens in a new tab)

  15. Análisis de pequeñas estructuras mediante ICP-MS: desarrollo metodológico y aplicaciones

    … desarrollo de metodologías analíticas basadas en ICP-MS para el análisis de pequeñas estructuras como células y nanopartículas de forma individual. Para ello, se han utilizado equipos de ICP-MS con distintos analizadores de masa equipados con diferentes sistemas de introducción de muestra, …

    oviedo Repository record for Análisis de pequeñas estructuras mediante ICP-MS: desarrollo metodológico y aplicaciones (opens in a new tab)

  16. Trace Elemental Variation in Dosidicus Gigas Statoliths Using LA-ICP-MS

    Range expansion events of the Humboldt squid reveal our inadequate understanding of populations of this species. Despite recent hatching, reproductive, tagging, genetic and dietary studies of Dosidicus gigas, much speculation remains concerning geographic migration, stock assessment and habitat …

    tamu Repository record for Trace Elemental Variation in Dosidicus Gigas Statoliths Using LA-ICP-MS (opens in a new tab)

  17. Stanovení stopových množství platiny v nádorové tkáni pomocí LA-ICP-MS

    … spektrometrií indukčně vázaného plazmatu (LA-ICP-MS) vyvinout metodiku umožňující mapování lidských nádorových tkání s dostatečným rozlišením pro studium přesné prvkové distribuce a asociace platinového léčiva ve tkáni. Během experimentů byla prokázána asociace izotopu 195Pt+ s makrofágy …

    brno-tech Repository record for Stanovení stopových množství platiny v nádorové tkáni pomocí LA-ICP-MS (opens in a new tab)

Page 1 of 90