Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 20 of 120 for “"ICP-MS analysis"”
-
ICP-MS analysis of fission product diffusion in graphite for high-temperature gas-cooled reactors
… from such reactors. We developed a method for analysis of fission product of fission product surrogate release rates from heated graphite samples. The graphite samples were infused with fission product surrogate material, and material which diffused from the graphite samples was transported via …
-
Icp-Ms Analysis of Lanthanide-Doped Nanoparticles: A Quantitative and Multiplexing Approach to Investigate Biodistribution, Blood Clearance, and Targeting
… inductively coupled plasma mass spectrometry (ICP-MS) to quantitatively determine a nanoparticle's blood clearance kinetics, biodistribution, and tumor delivery. This approach was applied to evaluate both passive and active tumor targeting, as well as metabolically directed targeting of …
-
MC-ICP-MS analysis of uranium and plutonium in keratinous samples for the purposes of nuclear forensic and biomarker establishment /
One objective of nuclear forensics is to identify the source of interdicted nuclear materials in order to help ensure the safety and security of special nuclear materials. Since 1995, The International Atomic Energy Agency (IAEA) has reported at least 16 different cases involving the illegal …
-
Applications of LA-ICP-MS analysis to zircon : assessing downhole fractionation and pre-treatment effects for U-Pb geochronology and trace element variations in accessory minerals from the Bushveld Complex
… coupled plasma-mass spectrometry (LA-ICP-MS) on zircon from layered intrusions are presented with the goals of advancing the analytical capabilities of LA-ICP-MS and showcasing the powerful geochemical fingerprinting of zircon. The effects of downhole fractionation, the time-dependent …
-
INVESTIGATION INTO POTENTIAL MAGMATIC CONTRIBUTIONS TO VOLCANOGENIC MASSIVE SULFIDE DEPOSITS: METHOD DEVELOPMENT FOR LA-ICP-MS ANALYSIS OF FLUID INCLUSIONS AND CRITICAL ASSESMENT OF THE WINDY CRAGGY DEPOSIT, NORTHWESTERN BRITISH COLUMBIA, CANADA
… the formation of volcanogenic massive sulfide (VMS) deposits has been gaining acceptance in the scientific community. The world-class Windy Craggy Cu-Co-Au deposit (>300 MT @ 2.12 wt.% Cu) located in northwestern British Columbia is the ideal location to investigate this potential for multiple …
-
Sources and analysis of iodine in Singapore diet
… INDUCTIVELY COUPLE PLASMA MASS SPECTROMETRY(ICP-MS) AND THE VISIBLE SPECTROPHOTOMETRY (COLORIMETRIC TECHNIQUE), WERE PERFORMED IN THIS STUDY. IODINE CONTENT IN THE INFANT FOODS EXAMINED MET THE DAILY REQUIRED INTAKE. ALSO, THE POSSIBLE FACTORS INFLUENCING THE IODINE CONTENTS IN DIFFERENT …
-
Differentiation of paper types using element profiles generated using inductively coupled plasma-optical emission spectroscopy and inductively coupled plasma-mass spectrometry
The analysis of questioned documents in a forensic laboratory traditionally focuses on the visual examination of the physical properties of the paper such as brightness and thickness. Improvements in the paper making process have made visual differentiation of different types of paper difficult …
-
Investigating metal/nanocolloid interactions in landfill leachates using AF4-HR-ICP-MS
… fraction (<100 nm), AF4 coupled with HR-ICP-MS was selected (alongside AFM and DLS) and optimised for use with landfill leachates. UV254 and Fluorescence spectroscopy were also used as detectors for AF4 to detect organic colloids.<br/>AF4-HR-ICP-MS analysis was carried out both offline …
-
XCT, SEM, and LA-ICP-MS map investigation of chondrule FGRS in CM2 Aguas Zarcas
… investigates the formation of fine-grained rims (FGRs) and their relationship to the matrix in CM2 Aguas Zarcas (AZ), combining scanning electron microscopy (SEM), X-ray computed tomography (XCT), and laser-ablation inductively coupled plasma mass spectroscopy (LA-ICP-MS) analyses, enabling a …
-
RILIEVO DI FATTORI XENOBIOTICI, CON PARTICOLARE RIFERIMENTO A NICOTINA E COTININA, IN CAMPIONI ISTOLOGICI APPARTENENTI A FETI E NEONATI DECEDUTI PER CAUSE NATURALI.
… tests for toxicological substances and then by ICP-MS analysis for 61 different metals. At last, all the 151 samples have been subjected to UPLC/MS-MS technique for the relief and dosage of nicotine and cotinine.
-
Integrity of Drilling Waste Sumps, Mackenzie Delta Area, NT
… the sumps. These surveys were complimented by ICP-MS analysis of soil samples to determine concentrations of Na, Cl and K at the sites. Three sites, one in the uplands and two in the delta appeared to be holding the saline fluids in place; elsewhere there was little difference in conductivity …
-
Airborne Particulate Matter Sample Analysis Using Dried-Droplet Standards and Laser Ablation Inductively Coupled Plasma Mass Spectrometry
… inductively couple plasma mass spectrometry (LA-ICP-MS) has become a popular technique for direct analysis of trace elements in solids. It is however important that LA-ICP-MS analysis is performed together with adequate calibration in order to provide quantitative data. In this work, we developed …
-
Fundamental and methodological investigations for the improvement of elemental analysis by inductively coupled plasma mass spectrometry
… of inductively coupled plasma mass spectrometry (ICP-MS) and laser ablation (LA) ICP-MS. The emission behavior of individual droplets and LA generated particles in an ICP is studied using a high-speed, high frame rate digital camera. Phenomena are observed during the ablation of silicate glass …
-
Conducting Materials in Electrochemical Analysis and Metal Extractions
Conducting materials (CMs) for analytical applications have enormously increased due to their unique physical and chemical properties and their ability to interact with various analytes. This dissertation focuses on applications of various types of CMs and their composites for electrochemical …
-
VALIDATION OF AGE AND GROWTH USING MICROCONSTITUENT ANALYSIS OF FISH HARDPARTS
… validation using trace element microconstituent analysis of hardparts. The optical zones of annuli are hypothesized to be the result of seasonal changes in organic content and experienced temperature, either of which can result in cycles of trace elements associated with annulus formation. Using …
-
Mobility and the Landscape: Investigating mobility of individuals at Wadi Faynan 100 using minimally invasive strontium isotope analysis
… coupled plasma-mass spectrometry (LA-MC-ICP-MS) to observe movement to and from the local area. Strontium (Sr) isotope ratios throughout the developmental periods of human enamel were used to indicate locality and patterns of mobility at WF100. Thirty-one samples consisting of a …
-
Radiochemical and analytical methods of analysis of radiological dispersal devices
… developed and used for sample preparation for analysis. Mass spectrometry (ICP-MS) analysis was then used to identify and quantify impurities and isotope ratios in iridium from various locations across the country. The second research project has developed a series of nanoparticles for use as …
-
Investigation of Novel Electrochemical Synthesis of Bioapatites and Use in Elemental Bone Analysis
… and as a calibration material for elemental analysis in human bone. Optimal conditions of electrochemically deposited uniform apatite coatings on stainless steel were investigated. Apatite is a ceramic with many different phases and compositions that have beneficial characteristics for …
-
Geophysical, geochemical and arable crop responses to archaeological sites in the Upper Clyde Valley, Scotland
… conditions, and these were followed up by ICP-MS analysis of the plants and the archaeological soils in which they had grown, in an attempt to link any changes in elemental compositions with the growth responses, and to the geophysical responses recorded at the soil sampling points or for …
-
An evaluation of instrumental tools to screen for the presence of brominated flame retardants
… proved to be accurate to 94% (relative to LA-ICP-MS results), making the technique (used with the developed calibration) reliable for the quantification of Br in polymers. REEs concentrations obtained with LA-ICP-MS were used to evaluate the origin of contaminants in FCAs and toys. - The …
Page 1 of 6