Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 3430 for “"ICP."”.

  1. New development in ICP spectrometry: low flow torch for axial viewing ICP-AES & studies in semiconductor analysis by ICP-MS

    … flow torch has been developed for axially viewed ICP-AES. Outer argon flow has been drastically reduced (less than 7 L min-1 ) by cooling the torch wall with air passing through a cooling jacket added to the outside of a Fassel torch. The plasma is viewed axially through a cooled cone interface …

    iastate Repository record for New development in ICP spectrometry: low flow torch for axial viewing ICP-AES & studies in semiconductor analysis by ICP-MS (opens in a new tab)

  2. Laser ablation ICP spectrometry.

    This thesis reports investigations into laser ablation inductively coupled plasma emission spectrometry for rapid elemental analysis of a diverse range of samples: glasses, aqueous solutions, oils, coated steels and glasses, and biological samples.Bulk analysis of glasses for major, minor and trace …

    sheffield-hallam Download PDF for Laser ablation ICP spectrometry. (opens in a new tab)

  3. Multivariate Calibration For ICP-AES

    … of metals is now a major application area for ICP-AES, however, the technique suffers from both spectral and non-spectral interferences. This thesis details the application of univariate and multivariate calibration methods for the prediction of Pt, Pd, and Rh in acid-digested and of Au, Ag and …

    plymouth Repository record for Multivariate Calibration For ICP-AES (opens in a new tab)

  4. Developments in ICP-MS: electrochemically modulated liquid chromatography for the clean-up of ICP-MS blanks and reduction of matrix effects by flow injection ICP-MS

    … of inductively coupled plasma mass spectrometry (ICP-MS). ICP-MS is a powerful technique for trace metal analysis in samples of many types, but like any technique has certain strengths and weakness. Attempts are made to improve upon those strengths and to overcome certain weaknesses.;One standout …

    iastate Repository record for Developments in ICP-MS: electrochemically modulated liquid chromatography for the clean-up of ICP-MS blanks and reduction of matrix effects by flow injection ICP-MS (opens in a new tab)

  5. ICP Analysis of Solids/Waste Slurries

    … slurries into an inductively coupled plasma (ICP) spectrometer offers a rapid and easy method for the analysis of major, minor, and trace elements in coal, coal ash, cements, and refractory materials. In this study aqueous slurries of 6 coals were prepared by milling with a stirred-ball slurry …

    wku-diss Repository record for ICP Analysis of Solids/Waste Slurries (opens in a new tab)

  6. Determination of Potentially Toxic and Essential Elements in Couscous From Arabic Countries Using ICP-MS and ICP-OES

    … was carried out by inductively coupled plasma (ICP) optical emission spectrometry (OES) and mass spectrometry (MS), which were both used to assess the bio-accessibility of potentially toxic and essential elements in couscous. An ICP-MS instrument equipped with a collision-reaction interface …

    queens Repository record for Determination of Potentially Toxic and Essential Elements in Couscous From Arabic Countries Using ICP-MS and ICP-OES (opens in a new tab)

  7. ICP Enhanced HIPIMS System Design and Characterisation

    A custom inductively coupled plasma assisted high-power impulse magnetron sputtering system was designed and assembled for the study of E x B plasma spoke instabilities. The magnetron plasma was characterized using time-resolved Langmuir probe, floating probe, optical emission spectroscopy and …

    sask Repository record for ICP Enhanced HIPIMS System Design and Characterisation (opens in a new tab)

  8. Fundamental And Applied Measurements In ICP-MS

    Fundamental and applied aspects of ICP-MS have been investigated to gain an increased understanding of the technique and improve on its analytical capabilities. Dissociation temperatures of polyatomic ions were calculated using a double-focusing sector instrument, to obtain more reliable mass …

    plymouth Repository record for Fundamental And Applied Measurements In ICP-MS (opens in a new tab)

  9. Fundamental Studies Of Interferences In ICP - MS

    … for diatomic ions which cause interferences in ICP-MS, was compiled. The equilibration temperature, calculated using the different methods and using various diatomic ions as the thermometric probes, was between c.a. 400 - 10,000 K in the central channel, and between c.a. 600 - 16,000 K when the …

    plymouth Repository record for Fundamental Studies Of Interferences In ICP - MS (opens in a new tab)

  10. Structure and dynamics of Pseudomonas aeruginosa ICP

    … aeruginosa inhibitor of cysteine peptidases (PA-ICP) is a potent protein inhibitor of papain-like cysteine peptidases (CPs) identified in Pseudomonas aeruginosa, an opportunistic pathogenic bacteria that can cause severe infections in human. It belongs to the newly characterized natural CP …

    glasgow Download PDF for Structure and dynamics of Pseudomonas aeruginosa ICP (opens in a new tab)

  11. Ion Transport in a Commercial ICP-MS

    … an inductively coupled plasma mass spectrometer, ICP-MS, depends on the instrument's ability to transport sample ions through the vacuum interface and focus the ions into a well-defined beam that will eventually reach the mass analyzer. In this study two main experiments were performed on the …

    byu Repository record for Ion Transport in a Commercial ICP-MS (opens in a new tab) Download PDF for Ion Transport in a Commercial ICP-MS (opens in a new tab)

Page 1 of 172