Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 31 for “"ICRU"”.
-
Deposition of Energy From Low-Energy Neutrons in the Icru Tissue Sphere
… throughout the spherical phantom having the ICRU-prescribed 4-element tissue composition. The basic studies involved broad, parallel beams; but the data were easily used to provide information on isotropic beam conditions also. Average dose values were easily determined. Except for the …
-
Assessment of Quantities for Radiation Protection in the ICRU Standard Tissue Sphere for Intermediate Energy Neutrons
Made available in DSpace on 2017-07-06T18:42:42Z (GMT). No. of bitstreams: 3 Lee_Jai_K_PhD.pdf: 93663248 bytes, checksum: 62684099d29cc019e5de385e150a7781 (MD5) Lee_Jai_K_PhD_ABS.pdf: 1035489 bytes, checksum: 538a1053f0813680985eedfc938dbb43 (MD5) license.txt: 4813 bytes, checksum: …
-
Influência das novas grandezas operacionais propostas pela ICRU 95 na resposta de monitores de área para fótons
… Commission on Radiation Units and Measurements (ICRU) e a International Commission on Radiological Protection (ICRP) publicaram um relatório conjunto que propõe novas grandezas operacionais, definidas nos mesmos fantomas antropomórficos das grandezas de proteção, para representar uma estimativa …
-
Calculation of Neutron Fluence-to-Dose Index Conversion Factors for the Standard Icru Tissue Phantom by the Monte Carlo Method
Made available in DSpace on 2014-12-14T06:26:06Z (GMT). No. of bitstreams: 1 7811221.pdf: 6872930 bytes, checksum: f215c7f7d666eb9881298cc5aefe2a5e (MD5) Previous issue date: 1978
-
Low-Energy Photon Dose Deposition in Tissue Slab and Spherical Phantoms
… 10 to 150 keV. Phantom compositions include: ICRU 4-element tissue, ICRU 10-element tissue, a tissue-substitute plastic, lucite, water, and polystyrene. Tabular data are presented for 0.007, 0.3 and 1.0 g/cm('2) depths. Results are compared with calculations of other workers and with …
-
Υπολογισμοί του παράγοντα ποιότητας (Q) αδρονίων στο εύρος ενεργειών 1MeV/u-1GeV/u μέσω αναλυτικών μοντέλων
… (TDRA) και τη σχέση Q(y) που συνίσταται από την ICRU στη δημοσίευση 40. Για τις δύο μεθοδολογίες, TDRA και ICRU, η στοχαστική κατανομή της μικροδοσιμετρικής γραμμιώδης ενέργειας (y) υπολογίστηκε μέσω του γενικευμένου αναλυτικού μοντέλου Xapsos με χρήση διαφορετικών κατανομών για το energy-loss …
-
Simulation and Analysis of Human Phantoms Exposed to Heavy Charged Particle Irradiations Using the Particle and Heavy Ion Transport System (PHITS)
… was then developed where tissue substitutes and ICRU-44 tissue could be interchanged to verify the validation of the soft tissue substitutes and and determine the required level of complexity of the entire phantom needed to achieve a specified precision as a replacement of the human body. The …
-
Adaptação de um sistema e monitoração individual externa para Raios X e Gama para avaliação do equivalente de dose pessoal Hp(10) , utilizando a técnica da dosimetria fotográfica
… Commission on Radiation Units and Measurements (ICRU): no sistema convencional (CNEN), as doses recebidas pelos trabalhadores são avaliadas através da dose individual Hx, onde dosímetros usados na superfície do tórax são calibrados em termos do kerma ar; no sistema recente (ICRU), as doses são …
-
Adaptação de um sistema e monitoração individual externa para Raios X e Gama para avaliação do equivalente de dose pessoal "Hp(10)"
… Commission on Radiation Units and Measurements (ICRU): no sistema convencional (CNEN), as doses recebidas pelos trabalhadores são avaliadas através da dose individual Hx, onde dosímetros usados na superfície do tórax são calibrados em termos do kerma ar; no sistema recente (ICRU), as doses são …
-
Estudo da resposta de monitores de radiação para medidas de equivalente de dose ambiental H*(10)
… a uma profundidade de 10 mm em uma esfera ICRU. Essa grandeza operacional é recomendada pela Comissão Internacional de Unidades e Medidas da Radiação (ICRU) para a monitoração de área. Com base na sua definição, as medidas em termos de H*(10) devem ser efetuadas com um instrumento com …
-
Ionization Chamber Dosimetry for High Energy Photon and Electron Beams: An Experimental Study
… been critical of the values of CE and Cλ by the ICRU as absorbed dose conversion factors for ionization chambers used in electron or photon beams.</p> <p> This report examines the subject in light of these recent works. Presented is a review of both theoretical and experimental results published …
-
Bewertung perkutaner Bestrahlungspläne mittels physikalischer und biologischer Kriterien
… aus den folgenden vier Kriterien berechnen: ICRU-Konformität (Betrachtung der Dosisabweichungen im Planungszielvolumen von den ICRU-Empfehlungen), Mittelwert und Homogenität der Dosis im Planungszielvolumen, relative Planungszielvolumendosis bzw. inverse relative Restvolumendosis und einem …
-
Space Radiation Interactions in Earth's Atmosphere, Low Earth Orbit, and Deep Space
… were then compared to published data from ICRU Report 84. HZETRN and DYASTIMA-R output comparable results, with MULASSIS consistently outputting lower values. HZETRN results did not converge like DYASTIMA-R and MULASSIS results; this is probably due to the user-input source particle …
-
Estimation of absorbed dose to adipose tissue from full field digital mammogram using Monte-Carlo simulation
… (biological effects of ionizing radiation) or ICRU (International Commission on Radiological Protection) reports.
-
Τεκμηρίωση της μείωσης της τοξικότητας στη θεραπεία του γυναικολογικού καρκίνου, μέσω της χρήσης συνδυασμού εξωτερικής ακτινοθεραπείας με σύγχρονες τεχνικές και βραχυθεραπείας με τρισδιάστατη απεικόνιση
… local disease control and patient survival (ICRU 38, ICRU 89). Due to this aforementioned need, the Greek state legally mandated the use of three-dimensional planning in brachytherapy (Government Gazette Issue B- 2408/31.08.2012).
-
Υπολογισμός απορροφούμενων και ισοδύναμων δόσεων για διαστημικές αποστολές στον Άρη
… Dose) στο διαπλανητικό μέσο για τη σφαίρα ICRU, η οποία χρησιμοποιείται για την προσομοίωση του ανθρώπινου σώματος. Τέλος, μέσω του μοντέλου dMEREM, θα υπολογιστεί η ισοδύναμη και δραστική δόση περιβάλλοντος στην επιφάνεια του πλανήτη Άρη. Όλοι οι υπολογισμοί θα γίνουν για τις ροές ηλιακών …
-
Quantitative basis for component factors of gas flow proportional counting efficiencies
… distribution for beta-particle energy spectra in ICRU 56 Appendix D and MCNP requirements are described and a correction for the bias introduced during the normalization process for beta spectra is provided. Counting efficiencies determined by empirical measurement and Monte Carlo simulations …
-
Determination of Wair value in high energy electron beam
… charge created into the energy deposited. The ICRU report 90 has reaffirmed the accepted value to be 33.97(12) eV and to be energetically independent above 10 keV. However, a recent publication by Tessier et al. (DOI: 10.1002/mp.12660) has shown a possible energy dependence. The present work …
-
Παρουσίαση του κώδικα MCDS και εφαρμογές στον υπολογισμό του RBE για ηλεκτρόνια
… του LET σε σύγκριση με τα δεδομένα της ICRU 90, με ιδιαίτερα υψηλές τιμές σε χαμηλές ενέργειες (T < 10 keV). Οι DSB βλάβες είναι αυξημένες στις ίδιες ενεργειακές περιοχές και τα DSBs υπολογισμένα από προσομοιώσεις με τον κώδικα Monte Carlo Geant4DNA είναι υψηλότερα από τον MCDS. Ακόμη, …
-
Beta and electron dose imaging using a microspectrophotometer system and radiochromic film
… found to be smaller than those quoted in the ICRU report 35 by a factor of 1.8 or less.</p>