Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 234 for “"IMRT"”.

  1. IMRT and Rotational IMRT (mARC) Using Flat and Unflat Photon Beams

    … intensity modulated radiation therapy (IMRT) and volumetric modulated arc therapy (VMAT), deal with the non-uniformity of the FFF beam profifile and produce homogeneous dose to the target as FF beams do. Siemens modified the Artiste linac in order to enable photon beam delivery with and …

    qucosa-diss

  2. Patient-specific quality assurance for IMRT

    … radiation therapy, QA is an integral part of the IMRT treatment process. This study evaluated two different QA modalities, a heterogeneous RANDO phantom and the MatriXX Detector. The RANDO phantom study evaluated the dosimetric accuracy of a helical TomoTherapy system which resulted in a benchmark …

    ut-knoxville Repository record for Patient-specific quality assurance for IMRT (opens in a new tab)

  3. Evaluation of Intensity Modulated Radiation Therapy (Imrt) Delivery Error Due to Imrt Treatment Plan Complexity and Improperly Matched Dosimetry Data

    Intensity modulated radiation therapy (IMRT) is a technique that delivers a highly conformal dose distribution to a target volume while attempting to maximally spare the surrounding normal tissues. IMRT is a common treatment modality used for treating head and neck (H&N) cancers, and the presence …

    uthsc Repository record for Evaluation of Intensity Modulated Radiation Therapy (Imrt) Delivery Error Due to Imrt Treatment Plan Complexity and Improperly Matched Dosimetry Data (opens in a new tab)

  4. An evaluation of patient-specific IMRT verification failures

    … of Intensity Modulated Radiation Therapy (IMRT) treatment plans involves comparing Portal Image (PI) -based three-dimensionally reconstructed (EPIDose) dose distributions to planned doses calculated using the Pencil Beam Convolution (PBC) algorithm. Discrepancies surpassing established …

    uvic Repository record for An evaluation of patient-specific IMRT verification failures (opens in a new tab)

  5. Knowledge-based IMRT treatment planning for prostate cancer.

    … goal of intensity-modulated radiation therapy (IMRT) treatment plan optimization is to produce a cumulative dose distribution that satisfies both the dose prescription and the normal tissue dose constraints. The typical manual treatment planning process is iterative, time consuming, and highly …

    duke Repository record for Knowledge-based IMRT treatment planning for prostate cancer. (opens in a new tab)

  6. Dose verification of a stereotactic IMRT treatment planning system

    … verify dose distributions for a new stereotactic IMRT (Intensity Modulated Radiation Therapy) treatment planning system. This technique combines the principles of stereotactic radiosurgery and IMRT to significantly increase the positioning accuracy compared with conventional IMRT . Ion chamber …

    ubc Repository record for Dose verification of a stereotactic IMRT treatment planning system (opens in a new tab) Download PDF for Dose verification of a stereotactic IMRT treatment planning system (opens in a new tab)

  7. Dosisvergleich von Bestrahlungsplänen bei HNO-Tumoren für IMRT-Techniken

    Auswertung und Vergleich von Bestrahlungsparametern von Intensitätsmodulierter Radiotherapie sowie Volumenmodulierter Strahlentherapie für Kopf-Hals-Tumoren

    cau-kiel Repository record for Dosisvergleich von Bestrahlungsplänen bei HNO-Tumoren für IMRT-Techniken (opens in a new tab)

  8. Quantification of Imrt Severity Scores For Improvement of Fmea Results

    … of intensity modulation radiation therapy (IMRT) requires perfect execution of a long, complicated chain of events; failure of any component of this process may contribute to dose delivery errors, compromising treatment quality and, more importantly, patient safety. Prospective, process-wide …

    uthsc Repository record for Quantification of Imrt Severity Scores For Improvement of Fmea Results (opens in a new tab)

  9. An Evaluation of The Consistency of Imrt Patient-Specific Qa Techniques

    … of an intensity modulated radiation therapy (IMRT) treatment, each plan must be validated through a measurement-based quality assurance (QA) procedure, known as patient specific IMRT QA. Many methods of measurement and analysis have evolved for this QA. There is not a standard among clinical …

    uthsc Repository record for An Evaluation of The Consistency of Imrt Patient-Specific Qa Techniques (opens in a new tab)

  10. Artificial Intelligence-Driven Planning Agents for Real-Time IMRT Plan Generation

    … for intensity-modulated radiation therapy (IMRT) for various treatment sites. Fluence map prediction for prostate simultaneous integrated boost (SIB) or Stereotactic Body Radiotherapy (SBRT) cases was selected for a feasibility study. Prostate cases have one of the most consistent anatomic …

    duke Repository record for Artificial Intelligence-Driven Planning Agents for Real-Time IMRT Plan Generation (opens in a new tab)

  11. Evaluation of Beam Angle Scoring Using MCNP and Applied to IMRT

    … beam arrangements are typically used for IMRT plans. This beam arrangement provides adequate dose coverage to the target while sparing dose to other structures. However, an equispaced beam arrangement may not provide the best dose coverage to the target while sparing dose to the other …

    gatech Repository record for Evaluation of Beam Angle Scoring Using MCNP and Applied to IMRT (opens in a new tab)

  12. IMRT treatment planning for arteriovenous malformations : patient stratification and dosimetric quality assurance

    … use of intensity-modulated radiotherapy (IMRT) has been advocated because, compared to 3D Conformal Radiotherapy (3DCRT), it leads to improved PTV conformity and Normal Tissue (NT) sparing. The aim of this study was: 1) to develop stratification rules for AVM patients based on benefits …

    ubc Repository record for IMRT treatment planning for arteriovenous malformations : patient stratification and dosimetric quality assurance (opens in a new tab) Download PDF for IMRT treatment planning for arteriovenous malformations : patient stratification and dosimetric quality assurance (opens in a new tab)

  13. Μελέτη του δείκτη γ κατά τον έλεγχο ποιότητας πλάνων IMRT και VMAT

    … έντασης (Intensity Modulated Radiation Therapy, IMRT, Volumetric Modulated Arc Therapy, VMAT), σύμφωνα με το πρωτόκολλο του TG-218, η κλινική συσχέτιση των gamma passing rates (%GP) και η σύγκριση των δισδιάστατων (2D) με τους τρισδιάστατους (3D) %GP κατά την ανίχνευση σφαλμάτων στη δόση. Υλικά …

    athens Repository record for Μελέτη του δείκτη γ κατά τον έλεγχο ποιότητας πλάνων IMRT και VMAT (opens in a new tab)

  14. Algoritmo transgenético para os problemas da geometria e da intensidade em IMRT

    Intensity Modulated Radiotherapy (IMRT) is a form of treatment of cancerous diseases in which the patient is irradiated with radiation beams, aiming to eliminate tumor cells while sparing healthy organs and tissues as much as possible. Each beam is divided into beamlets that may emit different …

    brazil-ufrn Repository record for Algoritmo transgenético para os problemas da geometria e da intensidade em IMRT (opens in a new tab)

  15. Monte Carlo simulation of modern techniques of intensity modulated radiation therapy (IMRT)

    … application to Intensity Modulated Radiotherapy (IMRT) and/or Gold Nanoparticle Therapy (GNPT). Emphasis is given to IMRT with and without the presence of gold nanoparticles while the main tool used for all the studies is Monte Carlo method of radiation transport The dissertation is divided into …

    greece Repository record for Monte Carlo simulation of modern techniques of intensity modulated radiation therapy (IMRT) (opens in a new tab)

  16. Benders decomposition and an IP-based heuristic for selecting IMRT treatment beam angles

    … map in Intensity Modulated Radiation Therapy (IMRT) planning, we apply Benders decomposition as well as develop a two-stage integer programming-based heuristic. Benders decomposition is first implemented in the traditional manner by iteratively solving the restricted master problem, and then …

    texas Repository record for Benders decomposition and an IP-based heuristic for selecting IMRT treatment beam angles (opens in a new tab)

  17. Automated review of patient position during DIBH breast hybrid IMRT using EPID images

    Deep Inspiration Breath Hold (DIBH) is a respiratory-gating technique employed in breast radiation therapy to lower the delivered radiation dose to the patient’s heart. When performing DIBH treatments, it is important to have a monitoring system to measure the quality of the patient's breath hold. …

    manitoba Repository record for Automated review of patient position during DIBH breast hybrid IMRT using EPID images (opens in a new tab)

Page 1 of 12