Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 8 of 8 for “"IMRT QA"”.
-
Comprehensive Calculation-Based Imrt Qa Using R&V Data, Treatment Records, and A Second Treatment Planning System
Purpose: Traditional patient-specific IMRT QA measurements are labor intensive and consume machine time. Calculation-based IMRT QA methods typically are not comprehensive. We have developed a comprehensive calculation-based IMRT QA method to detect uncertainties introduced by the initial dose …
-
An Evaluation of The Consistency of Imrt Patient-Specific Qa Techniques
… of an intensity modulated radiation therapy (IMRT) treatment, each plan must be validated through a measurement-based quality assurance (QA) procedure, known as patient specific IMRT QA. Many methods of measurement and analysis have evolved for this QA. There is not a standard among clinical …
-
IMRT treatment planning for arteriovenous malformations : patient stratification and dosimetric quality assurance
… use of intensity-modulated radiotherapy (IMRT) has been advocated because, compared to 3D Conformal Radiotherapy (3DCRT), it leads to improved PTV conformity and Normal Tissue (NT) sparing. The aim of this study was: 1) to develop stratification rules for AVM patients based on benefits …
-
Implementation of Upright Treatments For Lung and Head and Neck Cancers
… end-to-end test, the treatment plan passed the IMRT QA criteria of 0.95-1.05 for point dose and obtained a gamma index of 89.25%. Dosimetry verification demonstrated good agreement between the treatment plan doses and the delivered doses and obtained a point-dose dose difference of 2% and gamma …
-
Quality Assurance of Advanced Treatment Modalities Using Presage® Dosimeters
… plan should be included in patient-specific IMRT QA. A volumetric dosimeter such as PRESAGE® is able to provide a complete 3D measured dosimetry dataset with one treatment plan delivery. It was hypothesized that a PRESAGE® dosimeter would agree with 2D measurements within ±5%/3mm using a …
-
Development and Validation of Advanced Techniques for Treatment Planning and Verification in Megavoltage Radiotherapy
… by the advanced intensity modulated treatments (IMRT/VMAT). This is typically accomplished by the assessment of the treatment plan quality at the planning stage and then verification of the dose distributions through measurements on the phantoms or independent dose calculations prior to the …
-
Towards the Clinical Implementation of Online Adaptive Radiation Therapy for Prostate Cancer
… 50ms intervals. Based on these DMI inputs, the QA system performed three levels of monitoring/verification on the plan delivery process: (1) Following each input, actual and expected fluence maps delivered up to the current MLC position were dynamically updated using corresponding MLC positions …
-
An Investigation Of Uncertainties In Intensity Modulated Radiation Therapy
… using intensity modulated radiation therapy (IMRT) is complex, involving many sub-processes to commission a treatment platform and treat patients. Uncertainties within the individual sub-process can lead to inaccurate treatments and sub-optimal patient outcomes. This research focused on …