Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 20 of 1,246 for “"INDUCTIVELY COUPLED PLASMA-MASS SPECTROMETRY"”
-
Matrix effects in inductively coupled plasma mass spectrometry
… strong polyatomic ion signals common in inductively coupled plasma mass spectrometry (ICP-MS) can be used as internal standards to correct for matrix interferences. Signals for most of the polyatomic ions, including metal oxides, are suppressed by a Cs matrix to the same extent as analyte …
-
Characterization of Nanoparticles Using Inductively-Coupled Plasma Mass Spectrometry
… nanomaterials are properly used. Single Particle Inductively Coupled Plasma Mass Spectrometry (SP-ICP-MS) is a functional method that could fill the characterization need in the nanomaterial research field. Using data from both SP-ICP-MS tests and data from literature established characterization …
-
Sample introduction techniques for inductively coupled plasma mass spectrometry
… and non-conducting powdered samples with an inductively coupled plasma mass spectrometer (ICP-MS). Detection limits are in the [mu]g g[superscript]-1 range and relative precision and accuracy are ~5% for elements studied. The precision for isotope ratio measurements of non-conducting powders …
-
Relative Quantitation Of Peptides By Inductively Coupled Plasma Mass Spectrometry
… the detection/quantitation of biomolecules using Inductively Coupled Plasma Mass Spectrometry (ICR-MS) is focused on heteroatom containing (e.g. S. P, Se, Cu) compounds. This limits the scope of ICP-MS as a routine analytical tool in the bioanalytical sciences. To increase this scope novel …
-
⁹⁹Tc bioassay by inductively coupled plasma mass spectrometry (ICP-MS)
… means of analyzing <sup>99</sup>Tc In urine by inductively coupled plasma mass spectrometry (ICP-MS) has been developed. Historically, <sup>99</sup>Tc analysis was based on the radiometric detection of the 293 keV E<sub>Max</sub>. beta decay product by liquid scintillation or gas flow …
-
Isotopic analysis of environmental samples using inductively coupled plasma mass spectrometry
… using single-collector and multi-collector inductively coupled plasma mass spectrometry (ICP-MS). In particular, performances obtained measuring 208Pb/207Pb and 206Pb/ 207Pb ratios by single-collector ICP-MS at low sample consumption rates were investigated evaluating two micro-sample …
-
Forensic, Archaeological and Related Application of Inductively Coupled Plasma Mass Spectrometry
Inductively coupled plasma spectrometry (ICP-MS) is a powerful analytical instrument that can be applied to multiple disciplines for trace elements detection. In the first stage of this research, ICP-MS was used to group archaeological pottery sherds based on the compositional information obtained. …
-
Unique applications of solvent removal in inductively coupled plasma mass spectrometry
The determination of vanadium by inductively coupled plasma mass spectrometry (ICP-MS) is complicated by C1O⁺ ions from chlorine matrices. Cryogenic desolvation reduces the amount of chlorine reaching the plasma by condensing it as hydrogen chloride and reduces the amount of oxide formation by …
-
ELEMENTAL SPECIATION BY CHROMATOGRAPHIC SEPARATIONS INTERFACED TO INDUCTIVELY COUPLED PLASMA MASS SPECTROMETRY
… and multi-elemental capabilities, the inductively coupled plasma mass spectrometer has been routinely used for trace elemental analysis and as part of hyphenated systems for speciation analysis. Sample preparation is a critical area in elemental speciation analysis. It is important that …
-
Explorations into Nanoparticle Analysis by Single Particle Inductively Coupled Plasma Mass Spectrometry
… for nanoparticle analysis is single particle inductively coupled plasma mass spectrometry (spICPMS) as it solves many of the issues that other techniques struggle with, namely reproducibility and time required for analysis. A new peak area calibration technique is shown for spICPMS and …
-
Applications of inductively coupled plasma mass spectrometry to the analysis of biomolecules
<p>Size Exclusion Chromatography (SEC) was employed to separate DNA fragments in the buffer near physiological conditions so that the attributes and activeness of DNA was best maintained. DNA mixture at ppm level in this kind of buffer was spiked with either uranium or holmium at low ppb level. The …
-
Fundamental studies of the extraction process in inductively coupled plasma mass spectrometry
<p>A reduced pressure jet extracted from an inductively coupled plasma (ICP) was studied for information about conditions during the extraction process in inductively coupled plasma mass spectrometry (ICP-MS). The background spectrum and intensity ratio of ion lines to atom lines were similar to …
-
Constraining sources of mass bias in multi-collector inductively coupled plasma mass spectrometry
Multi-Collector Inductively Coupled Plasma Mass Spectrometers (MC-ICP-MS) are widely used instruments in Earth sciences to measure isotopic ratios in rock and environmental materials with high sensitivity, accuracy, and precision (i.e., sub-ppm range). However, even when samples undergo careful …
-
Elemental speciation and miniaturised sample introduction studies for inductively coupled plasma mass spectrometry
… the development of sample introduction for inductively coupled plasma mass spectrometry (ICPMS). The ultimate aim is to develop methods for conducting rapid speciation analysis. This is approached in two ways; firstly using liquid chromatography (LC) employing a column with a monolithic …
-
The development and application of inductively coupled plasma mass spectrometry for geochemical analysis
The applicability of the technique of inductively coupled plasma mass spectrometry to the analysis of geological samples was investigated using a variety of sample introduction techniques including: solution nebulisation; slurry nebulisation; flow injection; electrothermal vaporisation; and laser …
Page 1 of 63