Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 96 for “"IOL"”.

  1. Enhancement of a mechanical eye model setup for IOL testing

    … As this setup does not perfectly mimic the physiology of the human eye and the manipulation with it may sometimes introduce unwanted errors, the objective of this thesis is to fight the above-mentioned imperfections and develop a new, enhanced eye model setup which will address these.

    brno-tech Repository record for Enhancement of a mechanical eye model setup for IOL testing (opens in a new tab)

  2. Evaluation der Visusleistung nach beidseitiger Implantation einer Tecnis® Symfony IOL (Modell ZXR00) im Vergleich zu einer beidseitigen Implantation einer Tecnis® Monofokal 1-Piece IOL (Modell ZCB00)

    … ist die Tecnis Symfony Intraokularlinse (IOL), welche ein neues achromatisches diffraktives Linsendesign verwendet. Das Ziel der Studie ist eine Evaluation und ein Vergleich dieser sogenannten Intraokularlinse mit erweitertem Sehbereich („extended-depth-of-focus“), kurz EDOF-IOL, mit einer …

    fu-berlin Repository record for Evaluation der Visusleistung nach beidseitiger Implantation einer Tecnis® Symfony IOL (Modell ZXR00) im Vergleich zu einer beidseitigen Implantation einer Tecnis® Monofokal 1-Piece IOL (Modell ZCB00) (opens in a new tab)

  3. The 16 Days of Activism: Media ethics in news reporting of gender-based violence on News24 and IOL

    Gender-based violence (GBV) is a profoundly nuanced social phenomenon that demands comprehensive and contextualised media reporting. However, news coverage predominantly adopts an event-based approach, focusing on violent incidents rather than the broader systemic and historical conditions that …

    nwu-za Repository record for The 16 Days of Activism: Media ethics in news reporting of gender-based violence on News24 and IOL (opens in a new tab)

  4. Interpretation of Thermal Conductivity and Toroidal Momentum Transport in DIII-D Taking Into Account IOL and Pinch Velocity

    … toroidal viscous drag and a pinch velocity using IOL-corrected radial particle fluxes, therein demonstrating the importance of non-diffusive particle transport. The effects of ion orbit loss (IOL) on the interpretation of the radial ion heat flux are significant in the edge plasma. Furthermore, …

    gatech Repository record for Interpretation of Thermal Conductivity and Toroidal Momentum Transport in DIII-D Taking Into Account IOL and Pinch Velocity (opens in a new tab)

  5. Αίτια και τεχνικές ανταλλαγής ενδοφακών

    … or exchange of foldable intraocular lenses (IOLs) and the surgical techniques applied was conducted in the 1st Ophthalmological Department of the Aristotle University of Thessaloniki between the years 2001-2006. IOLs were replaced in a total of 121 eyes. The reasons for replacement were …

    greece Repository record for Αίτια και τεχνικές ανταλλαγής ενδοφακών (opens in a new tab)

  6. Women's knowledge, expectations and experience of induction of labour and the association with maternal anxiety

    Induction of Labour (IOL) is one of the fastest growing procedures in childbirth in the developed world with one in four women now being induced. The primary purpose of this study was to further develop the understanding of women's knowledge, expectations and experiences of IOL in order to identify …

    uts Repository record for Women's knowledge, expectations and experience of induction of labour and the association with maternal anxiety (opens in a new tab)

  7. Evaluation of the Accuracy of Intraocular Lens Formulae in the Different Ethnic Groups in Singapore

    … is replaced by an artificial intraocular lens (IOL) during the cataract operation. New IOL formulae have been developed over the years with the purpose of meeting the patient’s expectation of a clear vision with minimal residual refractive error after the cataract operation. This retrospective …

    aston Repository record for Evaluation of the Accuracy of Intraocular Lens Formulae in the Different Ethnic Groups in Singapore (opens in a new tab) Download PDF for Evaluation of the Accuracy of Intraocular Lens Formulae in the Different Ethnic Groups in Singapore (opens in a new tab)

  8. Difrakcinių intraokulinių lęšių kompiuterinis modeliavimas /

    The conventional diffractive IOL and multi – order diffractive IOL diffractive efficiencies are analysed in the Final Thesis. The object of the research – a conventional diffractive IOL and multi-order diffractive IOL diffractive efficiency study. The aim of the research – a diffractive intraocular …

    vilnius Repository record for Difrakcinių intraokulinių lęšių kompiuterinis modeliavimas / (opens in a new tab)

  9. Korrelation zwischen den Aberrationen höherer Ordnung und den klinischen Ergebnissen einer erweiterten monofokalen Intraokularlinse

    … Chirurgie. Die monofokale TECNIS Eyhance® IOL Modell ICB00 mit erweitertem Tiefenschärfebereich soll ein verbessertes Sehen im Intermediärbereich bei einem zur monofokalen Standard-IOL TECNIS® Monofocal 1-Piece IOL Modell ZCB00 vergleichbarem Fernvisus ermöglichen. Ziel dieser klinischen …

    fu-berlin Repository record for Korrelation zwischen den Aberrationen höherer Ordnung und den klinischen Ergebnissen einer erweiterten monofokalen Intraokularlinse (opens in a new tab)

  10. Intraocular lenses with functionalized surfaces by biomolecules in relation with lens epithelial cell adhesion

    … developed onto the implanted IntraOcular Lens (IOL) by the de-differentiation of Lens Epithelial Cells (LEC) undergoing Epithelial-Mesenchymal Transition (EMT). Literature has shown that the incidence of PCO is multifactorial including patient’s age or disease, surgical technique, and IOL design …

    liege Repository record for Intraocular lenses with functionalized surfaces by biomolecules in relation with lens epithelial cell adhesion (opens in a new tab) Restricted access

  11. Vergleich verschieden konzipierter asphärischer Intraokularlinsen im Hinblick auf das postoperative Kontrastsehvermögen

    … großen Spektrums an Kunstlinsen (IOL), die bei der Operation implantiert werden, kann inzwischen mehr als nur der Anspruch einer guten korrigierten Tagessehschärfe erfüllt werden. Asphärische IOL, die aberrationsneutral oder -negativ sein können, ermöglichen einen Ausgleich der …

    fu-berlin Repository record for Vergleich verschieden konzipierter asphärischer Intraokularlinsen im Hinblick auf das postoperative Kontrastsehvermögen (opens in a new tab)

  12. Optische Abbildungsqualität einer Extended-Depth-of-Focus-Intraokularlinse

    … Die Implantation multifokaler Intraokularlinsen (IOL) ermöglicht Patienten eine postoperative Brillenunabhängigkeit, birgt hingegen das Risiko von reduziertem Kontrastsehen und störenden optischen Phänomenen. Extended-Depth-of-Focus (EDOF)-IOL, eine neue Generation von IOL mit erweitertem …

    fu-berlin Repository record for Optische Abbildungsqualität einer Extended-Depth-of-Focus-Intraokularlinse (opens in a new tab)

  13. The relationship between anterior chamber depth and refraction after cataract surgery

    목적: 초음파 방식과 IOL Master® 방식을 이용하여 생체계측을 할 때 안축장과 전방 깊이, 각막 곡률에 따라서 선택할 수 있는 계산공식에 대하여 알아보고자 하였다. 대상과 방법: 아주대학교 병원에서 단일 술자에 의해 백내장수술을 받은 환자 65명 82안의 의무기록을 후향적으로 검토하였다. 생체계측은 IOL Master®, 수동각막곡률계, 침수식 초음파 검사를 순서대로 시행하여 측정하였다. 초음파 방식과 수동각막곡률계로 구한 생체계측 값을 SRK II, SRK-T, Holladay1, HofferQ 공식에 대입하였고 IOL …

    ajou Repository record for The relationship between anterior chamber depth and refraction after cataract surgery (opens in a new tab) Embargoed until 9999-12-31

  14. Evaluation of modern intraocular lenses

    Accommodating Intraocular Lenses (IOLs), multifocal IOLs (MIOLs) and toric IOLs are designed to provide a greater level of spectacle independency post cataract surgery. All of these IOLs are reliant on the accurate calculation of intraocular lens power determined through reliable ocular biometry. A …

    aston Download PDF for Evaluation of modern intraocular lenses (opens in a new tab)

  15. Evaluating techniques to improve visual performance with and assessment of premium intraocular lenses

    Premium Intraocular Lenses (IOLs) such as toric IOLs, multifocal IOLs (MIOLs) and accommodating IOLs (AIOLs) can provide better refractive and visual outcomes compared to standard monofocal designs, leading to greater levels of post-operative spectacle independence. The principal theme of this …

    aston Download PDF for Evaluating techniques to improve visual performance with and assessment of premium intraocular lenses (opens in a new tab)

  16. Anterior segment topography and aberrations for clinical applications

    … y en pacientes con lentes intraoculares (IOL). En particular, (1) se analiza la geometría de la córnea y las aberraciones en pacientes con queratocono antes y después de la cirugía de ICRS, y se analiza la posición de los ICRS; (2) se evalúa por primera vez in vivo la topografía del …

    valladolid Repository record for Anterior segment topography and aberrations for clinical applications (opens in a new tab)

  17. Changes in ion orbit loss, intrinsic rotation, and particle pinch across the L-H transition in DIII-D plasmas

    … plasma region and become ion orbit lost (IOL). Ions flowing in the counter-current (ctr-$I_{p}$) direction are more readily lost, exerting a net torque on the ions in the co-current direction. A particle-momentum-energy balance analysis, including the effects of IOL, was performed on three …

    gatech Repository record for Changes in ion orbit loss, intrinsic rotation, and particle pinch across the L-H transition in DIII-D plasmas (opens in a new tab)

  18. Direct and correlated responses to two -stage selection for ovulation rate and number of fully formed pigs at birth

    … for OR and FF. Three lines were used. Line IOL was derived from a line previously selected eight generations for an index to increase OR and embryonic survival. The other two lines, COL and C, originated from line Ci, the control for the index line. Line IOL had greater OR (4.24 ± .38 ova) …

    nebraska Repository record for Direct and correlated responses to two -stage selection for ovulation rate and number of fully formed pigs at birth (opens in a new tab)

  19. Protein sorption to contact lenses and intraocular lenses

    … contact lens materials and intraocular lenses (IOL). Methods: The proteins albumin and lysozyme were investigated as they are highly abundant in blood serum and tears, respectively. Proteins were conjugated with organic fluorescent probes and using confocal laser scanning microscopy (CLSM) the …

    waterloo Repository record for Protein sorption to contact lenses and intraocular lenses (opens in a new tab)

Page 1 of 5