Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 15 of 15 for “"IOLMaster"”

  1. The Repeatability of Peripheral Axial Length Measurements

    … peripheral axial length measurements using the IOLMaster in order to learn more about the growth of peripheral eye.</p><p>To assess the repeatability of the IOLMaster in measuring peripheral eye length, we performed five measurements of both non-cycloplegic and cycloplegic (two drops of 1% …

    ohiolink Repository record for The Repeatability of Peripheral Axial Length Measurements (opens in a new tab)

  2. Estudio clínico comparativo de la refracción obtenida tras facoemulsificación con implante de lente intraocular al realizar la biometría con el Iolmaster y Otiscan-1000 en función de la longitud axial

    … que recomienden la realización de la biometría IOLMaster® siempre que sea posible, y fundamentalmente en aquellos ojos con LA > 26 mm, con el objetivo de optimizar los resultados de todos los pacientes. Además, si no fuera posible realizar la biometría IOLMaster®, los resultados encontrados …

    valladolid Repository record for Estudio clínico comparativo de la refracción obtenida tras facoemulsificación con implante de lente intraocular al realizar la biometría con el Iolmaster y Otiscan-1000 en función de la longitud axial (opens in a new tab)

  3. Einfluss des Katarakt-Grades auf die optische Biometrie

    … im Vergleich zu Messungen des Handelsgerätes IOLMaster®. Ziel dieser Arbeit war es zu quantifizieren, bis zu welcher Katarakt-Dichte der IOLMaster® einsetzbar ist. Außerdem stellte sich die Frage, wie bei hochgradigen Katarakten die wenigen möglichen Wertausgaben mit starkem …

    wurz-thes Repository record for Einfluss des Katarakt-Grades auf die optische Biometrie (opens in a new tab)

  4. Novelty Optimisation Techniques For Myopia Assessment & Management

    … confirmed between the gold standard biometers, IOLMaster 700 and IOLMaster 500, for the key parameters of axial length, anterior chamber depth and corneal topography, where discrepancies in white-to-white corneal diameter values, following MiSight and NaturalVue contact lens wear, were minimal …

    aston Repository record for Novelty Optimisation Techniques For Myopia Assessment & Management (opens in a new tab)

  5. Posterior Corneal Astigmatism

    … using optical coherence tomography (OCT) of the IOLMaster 700 compares to previous estimates. 3) To assess whether IOLMaster 700 measurement of total corneal astigmatism, “total keratometry” (TK) is as accurate as Goggin nomogram adjusted keratometry (GNAK) values.

    adelaide Repository record for Posterior Corneal Astigmatism (opens in a new tab)

  6. Correlation Between AC/A Ratio and Ciliary Muscle Morphology in School-Age Children

    … correction. Axial length was measured with the IOLMaster. Temporal ciliary muscle images from anterior segment Vistante OCT at 1mm (CMT1), 2mm (CMT2), and 3mm (CMT3) posterior to the scleral spur at 0D and 4D stimulus levels and under cycloplegia were measured four times each. Accommodative …

    ohiolink Repository record for Correlation Between AC/A Ratio and Ciliary Muscle Morphology in School-Age Children (opens in a new tab)

  7. Ciliary Muscle Morphology in School-Age Children

    … Central axial length was measured with the IOLmaster. Four images of the temporal ciliary muscle were taken with the Visante OCT at three different stimulus levels (0D, 4D, 6D) while accommodative response and pupil size were monitored concurrently with the PowerRefractor. Accommodative …

    ohiolink Repository record for Ciliary Muscle Morphology in School-Age Children (opens in a new tab)

  8. BW - Decision support in ophthalmology: blueWorks

    … CT-80, querato-refractómetro KR-8900, biómetro IOLMaster e o perímetro HFA-II) e, finalmente, os módulos de integração desenvolvidos para os equipamentos AT550, CT-80 e KR-8900. PALAVRAS CHAVE Oftalmologia, interoperabilidade, Engenharia Reversa (com fins de interoperabilidade), RS-232, …

    coimbro Repository record for BW - Decision support in ophthalmology: blueWorks (opens in a new tab)

  9. Biomechanical aspects of the anterior segment in human myopia

    … examined using Partial Coherent Interferometry (IOLMaster, Zeiss), Optical Coherent tomography (Visante OCT), rotating Scheimpflug photography (Pentacam, Oculus) and 3-D Magnetic Resonance Imaging (MRI). Subject groups were employed that allowed investigation of variation pertaining to ethnicity …

    aston Repository record for Biomechanical aspects of the anterior segment in human myopia (opens in a new tab)

  10. Effect of a novel osteopathic technique on the axial length of the eye

    … measured using partial coherence interferometry (IOLMaster, Carl Zeiss Meditec, Germany) operated by qualified optometrists. Phoria was measured with a Maddox wing to determine whether there was any change in extraocular muscle tension. Tests for stereo acuity and the near point of convergence …

    unitec Repository record for Effect of a novel osteopathic technique on the axial length of the eye (opens in a new tab)

  11. Peripheral refraction: relationship to myopia, and manipulation using contact lenses

    … to direct axial length measurements with the IOLMaster in the nasal retina and to underestimate axial length in the temporal retina. Although not entirely comparable, peripheral refraction is still able to give information on the shape of eyes with different refractive errors. Conventional …

    unsw Repository record for Peripheral refraction: relationship to myopia, and manipulation using contact lenses (opens in a new tab)

  12. Clinical performance and biological interactions during scleral contact lens wear

    … be fitted; and at last, that other devices (such IOLMaster) or techniques (ImageJ) can provide objective values of the central corneal clearance and can be substitutes for the standard subjective measure. The last part of the study showed that scleral lenses promote large gains of visual acuity …

    minho-thes Repository record for Clinical performance and biological interactions during scleral contact lens wear (opens in a new tab)

  13. The Effect of Axial Length on Red and Blue Light-Evoked Pupil Responses in Children Depends on Season

    … diopters (non-cycloplegic autorefraction). The IOLMaster was used to measure axial length. Subjects were exposed to three different protocols where full-field stimuli oscillated between colored light and dark at 0.1 Hz in the following order: 1) alternating red and blue, 2) red-only, and 3) …

    ohiolink Repository record for The Effect of Axial Length on Red and Blue Light-Evoked Pupil Responses in Children Depends on Season (opens in a new tab)

  14. Investigation of Myopic Periphery Affecting Choroidal Thickness

    … nasal, temporal, and superior) with the Zeiss IOLMaster, and subfoveal choroidal thickness changes were measured with a Lenstar biometer. All subjects responded to the orthokeratology treatment well, with acceptable acuity and physiologic response to overnight wear. It is interesting to note …

    ohiolink Repository record for Investigation of Myopic Periphery Affecting Choroidal Thickness (opens in a new tab)

  15. Associations between Henle fiber layer thickness and age, refractive error, and axial length in a healthy population

    … length was measured using optical biometry (IOLMaster, Zeiss). Spectral-domain optical coherence tomography (Spectralis, Heidelberg) was used to acquire offset images of the central 15 degrees of the macula in both eyes. This technique allowed the HFL to be imaged in the superior, inferior, …

    ohiolink Repository record for Associations between Henle fiber layer thickness and age, refractive error, and axial length in a healthy population (opens in a new tab)