Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 7 of 7 for “"ISO 10819"”

  1. Investigation of issues related to the revision of ISO 10819

    … a proposed change to the input spectra for the ISO 10819 antivibration glove tests. Secondly, this study investigates the effect of palm adapter geometry on linear transmissibility and mean corrected transmissibility values. Finally, the effect of test subject training is discussed and …

    unlv Repository record for Investigation of issues related to the revision of ISO 10819 (opens in a new tab)

  2. Modeling of hand-arm-glove vibration system and testing and evaluating of antivibration gloves

    Work-related hand-arm disorders (HAVS) caused by exposure to vibration while operating vibrational tools were discussed; no clear dose-effect relationship between vibration exposure and HAVS was found yet. Ways to avoid or delay harmful impact on workers were explored, one means of which is using …

    unlv Repository record for Modeling of hand-arm-glove vibration system and testing and evaluating of antivibration gloves (opens in a new tab)

  3. Design of Biomechanical Sensor System for Laboratory- and Field-based Measurements of Hand-Arm Vibration Exposures and Palm and Finger Forces

    … recommended in the International Standards: ISO 10819 and ISO 5349. Due to the differences in the biodynamic responses of the palm and fingers, it is important to differentiate between palmar and finger exposure measurements, where the occurrence of HAVS may be more dominant. Grip and feed …

    uconn-diss Repository record for Design of Biomechanical Sensor System for Laboratory- and Field-based Measurements of Hand-Arm Vibration Exposures and Palm and Finger Forces (opens in a new tab)

  4. Evaluation of Anti-Vibration Gloves in a Manufacturing Setting

    … environment with specific tools. Currently ISO 10819 is used to certify gloves as "anti-vibration"; however, the standard only tests a static position and force which may not accurately represent a gloves ability to reduce vibration exposure during specific tasks. The aims of this study are …

    washington Repository record for Evaluation of Anti-Vibration Gloves in a Manufacturing Setting (opens in a new tab)

  5. Kertészeti kisgépek rezgésterhelése és annak mérése = The vibration exposure of small horticultural tools and its reduction

    … gépkezelőt érő rezgésterhelés vizsgálata az ISO 5349:2001 szabvány alapján, illetve olyan tényezők meghatározása, amelyek hatással lehetnek a kezelőt érő rezgésterhelésre és befolyásolhatják a kézre ható rezgés mérési eredményének pontosságát. Másrészt különböző anti-vibrációs kesztyű rezgést …

    corvinus Repository record for Kertészeti kisgépek rezgésterhelése és annak mérése = The vibration exposure of small horticultural tools and its reduction (opens in a new tab)

  6. VIBRATION TRANSMISSION CHARACTERISTICS AND GRIP STRENGTH PRESERVATION OF ANTI-VIBRATION GLOVES

    … as vascular, neurological and musculoskeletal disorders of the hand-arm system, which are collectively termed as hand-arm vibration syndrome (HAVS). In order to decrease the effects of HTV, substantial efforts have been made to protect the operator from the vibrating tools and decrease the …

    concordia

  7. Development of a methodology for integrated performance analyses of anti-vibration gloves for controlling the hand-transmitted vibration

    … tools has been associated with an array of disorders of the hand-arm system, collectively referred to as the hand-arm vibration syndrome (HAVS). The risk of HAVS among hand-held power tools operators has been related to the nature of HTV exposure and the mechanical coupling of the hand with a …

    concordia