Sex Differences in the Influence of Spinal Accelerometer Orientation on Transmissibility During Seated Whole-Body Vibration
… risk and exposure limits are defined in the ISO 2631-1 basicentric coordinate system (BCS). However, the accelerometers’ internal coordinate system becomes misaligned with the BCS when attached to the body, impacting the ability to measure transmissibility accurately. A VICON motion capture …
-
Assessing whole-body vibration transmissibility in children's bicycle trailers
… head, 2) to determine health risks based on an ISO 2631-1 health guidance caution zone (HCGZ) analysis, and 3) to determine if vibration exposure characteristics differed when riding on gravel compared to a paved terrain. The findings revealed an associated health risk, with levels of vibration …
-
Methods for Assessing Exposure to Whole-Body Vibration and Mechanical Shocks Induced During Forklift Operations
… International Organization of Standardization ISO 2631-1, ISO 2631-5, British Standard BS 6841, and American Conference of Governmental Industrial Hygienists ACGIH and comparing them, also comparing the results to the European Union action level and vibration levels recommended by different …
-
Development of MRE-based Semi-Active Seat Suspension System for the Mitigation of Whole-Body Vibration
… the current standard on WBV exposure assessment, ISO 2631/1:1997. The 4-DOF seated human model was then combined with the single DOF model of the seat suspension to derive the coupled 5-DOF human and seat suspension system. The 5-DOF model was utilized to obtain the optimal passive parameters …
-
Foot-transmitted vibration: exposure characteristics and the biodynamic response of the foot
… health risks were determined based on both ISO 2631-1 (1997) for WBV and ISO 5349-1 (2004) for HAV. Seventeen participating operator’s also reported musculoskeletal discomfort. Seventeen male participants ranging between 24-61 years of age, with an average height and mass of 175.0cm and …
-
Investigation of bus users’ motion comfort due to wind and bridge motion excitations
… weighted according to weighting filters from the ISO 2631-1. By using the mentioned ISO standard, bus users’ comfort could be assessed by comparison of bus occupants’ acceleration limits. Motion sickness was assessed numerically by the Motion Sickness Dose Value equation given in ISO 2631-1, …
-
Numerical Modelling of the Effects of Vibration in Helicopters for Prediction and Analysis of Human Comfort Assessment
… torso and pelvis are studied as well. Based on ISO 2631-1, the whole body vibration (WBV) and comfort assessment for the pilot and the patient are carried out during the six simulated flight conditions. The results on root mean square (r.m.s) of frequency-weighted acceleration at the centre …
-
Comparison of Whole-body Vibration Attenuation Properties Between Active and Passive Suspension Seats
… A(8) daily vibration exposures were below the ISO 2631-1 HCGZ caution limit. This suggests that there is no difference in health risks between seats.
-
Effects of Muscle Fatigue on Muscle Latency and Muscle Activation under Whole-Body Vibration
… the risk of low back injuries. Additionally, the ISO 2631-1 comfort ratings did not increase with fatigue, showing a disconnect between these comfort ratings and the perceived discomfort ratings in a fatigued muscle state.
-
Avaliação dos níveis de vibração em motoristas de composições veiculares de carga em diferentes pistas
… comparadas com os limites fornecidos na norma ISO 2631-1 (1997), constatando-se que os níveis de acelerações que os motoristas destas composições estão expostos, apresentam níveis de aceleração RMS e VDV acima dos limites recomendados pela referida norma para a maioria das situações analisadas. …
-
Otimização de dispositivos passivos de dissipação de energia - TMD e K-Damper - para redução de vibração em um modelo de ônibus utilizando o CIOA
… de pista estocásticos de classe C, conforme a ISO 8608, 2016, e as otimizações foram realizadas utilizando o Circle-Inspired Optimization Algorithm (CIOA). As análises iniciais no modelo original indicaram que, nas condições de pista consideradas, a aceleração ponderada no assento do motorista …
-
Comprehensive Assessmentof Comfort (Motion Sickness) in Vehicles.
… The second part evaluates the improvement of the ISO 2631-1 standard for assessing motion sickness, using computational tools. The literature review identified 23 relevant patents from an initial pool, focusing on technologies and methods related to vehicle dynamics, human physiology, and …
-
Absorbed power as a measure of whole body vehicular vibration exposure
… of the model and of the guidance provided in ISO 2631-1 (1997) to relate vibration exposure with the risks of health effects, health guidance caution zones are established based on absorbed power. The eigenvalues and natural frequencies, damping ratios and damping ratio matrix, the vertical …
-
Propuesta de evaluación experimental de la vibración y el confort de las personas en silla de ruedas sobre superficies peatonales
… cuantitativos según lo estipulado en la Norma ISO 2631-1 “Vibraciones en Cuerpo Entero” para poder establecer relaciones entre la confortabilidad de una persona bajo parámetros subjetivos y la evidencia de los resultados cuantitativos del Vibrómetro. La presente tesis inicia con un amplio …
-
Avaliação dos níveis de vibração de corpo inteiro sofridos por motoristas de ônibus urbanos em diferentes tipos de pistas
… estrada na exposição à VCI de acordo com a norma ISO 2631-1 (1997). Dois motoristas diferentes guiaram o mesmo ônibus urbano sobre diferentes tipos de pista: asfalto regular, paralelepípedo e estrada de chão, caracterizando condições comuns nas cidades brasileiras. Para avaliar as vibrações …
-
RIDE VIBRATION AND COMPACTION DYNAMICS OF VIBRATORY SOIL COMPACTORS
… capability is subsequently assessed using the ISO-2631-1 (1997) guidelines and commonly accepted compaction criteria, respectively. The validity of the proposed model is demonstrated by comparing the model responses with the measured data. Comprehensive parametric analyses were subsequently …
-
The Characterization of Whole-Body Vibration Exposures in Forklift Operators
… (WBV) are known factors for musculoskeletal disorders. Although forklift operators are heavily exposed to WBV, there is still a lack of studies that systematically evaluate different interventions for mitigating WBV exposures. The present dissertation objectives were: 1) to characterize …
-
Design of a Rear-Wheel After-Market Suspension System for Manual Wheelchairs
… for vibration loads on wheelchair users (ISO 2631-1), are not meet by today's standard wheelchairs. Today's wheelchairs need to be able to absorb everyday shock loads, thereby minimizing the energy transmitted to the user. The chosen design is based around the concept of adding shock …
-
Measuring human foot-transmitted vibration exposure in mining: a field study and prototype measurement insole design
… that existing whole-body vibration standards (ISO 2631-1) may underestimate risk for standing workers, as analysis at higher frequency ranges associated with hand-transmitted vibration identified additional individuals within the Health Guidance Caution Zone. These findings highlight a gap in …