Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 17 of 17 for “"ISO 5349"”.

  1. Vibration Level Characterization from a Needle Gun Used on U.S. Naval Vessels

    … an accelerometer on the needle gun following ISO 5349-1:2001 and ISO 5349-2:2001 methods. Significant differences were observed individually in pressure (p< 0.0001), contact (p< 0.0001)), and subjects (p< 0.001). In addition, there was a significant interaction between contact and pressure (p< …

    usf Repository record for Vibration Level Characterization from a Needle Gun Used on U.S. Naval Vessels (opens in a new tab)

  2. Caracterização dos níveis de vibração em motoristas de ônibus : um enfoque no conforto e na saúde

    … de acordo com as recomendações das normas ISO 2631 (1974 e 1997) e ISO 5349 (1986), utilizando-se acelerômetros uni-axiais, um computador com placa conversora analógica para digital (A/D), e programas desenvolvidos na plataforma de programação gráfica HPVee para aquisição e avaliação dos …

    brazil-ufrgs Repository record for Caracterização dos níveis de vibração em motoristas de ônibus : um enfoque no conforto e na saúde (opens in a new tab)

  3. Foot-transmitted vibration: exposure characteristics and the biodynamic response of the foot

    … health risks were determined based on both ISO 2631-1 (1997) for WBV and ISO 5349-1 (2004) for HAV. Seventeen participating operator’s also reported musculoskeletal discomfort. Seventeen male participants ranging between 24-61 years of age, with an average height and mass of 175.0cm and …

    laurentian Repository record for Foot-transmitted vibration: exposure characteristics and the biodynamic response of the foot (opens in a new tab)

  4. Design of Biomechanical Sensor System for Laboratory- and Field-based Measurements of Hand-Arm Vibration Exposures and Palm and Finger Forces

    … recommended in the International Standards: ISO 10819 and ISO 5349. Due to the differences in the biodynamic responses of the palm and fingers, it is important to differentiate between palmar and finger exposure measurements, where the occurrence of HAVS may be more dominant. Grip and feed …

    uconn-diss Repository record for Design of Biomechanical Sensor System for Laboratory- and Field-based Measurements of Hand-Arm Vibration Exposures and Palm and Finger Forces (opens in a new tab)

  5. Pneumatic Tool Hand-Arm Vibration and Posture Characterization Involving U.S. Navy Shipboard Personnel

    … an accelerometer on the pneumatic tool following ISO 5349-1:2001 and ISO 5349-2:2001 methods.A three-way ANOVA (subjects by tool, by condition, (cleaning vs. not cleaning) and tool vs. condition) with replicates (not including idle conditions) was conducted on the data. The analysis included the …

    usf Repository record for Pneumatic Tool Hand-Arm Vibration and Posture Characterization Involving U.S. Navy Shipboard Personnel (opens in a new tab)

  6. Wave propagation in human tissue from transient high frequency vibrations

    … like peripheral vascular and peripheral neural disorders of the fingers and hands. These disorder symptoms include numbness, pain, and blanching of the fingers. ISO 5349 claims that the vibrating machines with frequencies in the range of 8-1250 Hz must be regulated. However, vibrations with …

    chalmers Repository record for Wave propagation in human tissue from transient high frequency vibrations (opens in a new tab)

  7. Ultravibrationer i mänskliga fingrar och hur fingrar förhåller sig till en vibrerande yta

    Nuvarande standard (ISO 5349-1:2001) för mätning och riskbedömning av vibrationer tar endast hänsyn till vibrationer upp till 1250 Hz, och inte ultravibrationer. Det finns också osäkerheter kring skaderisken vid exponering av ultravibrationer på grund av bristande data på området. Då …

    chalmers Repository record for Ultravibrationer i mänskliga fingrar och hur fingrar förhåller sig till en vibrerande yta (opens in a new tab)

  8. Design and testing of [a] vibratory force measurement system for hand-arm vibration applications

    … usage of vibrating tools in the United States: ISO 5349, ACGIH-TLY and ANSI S3.34. These standards use the acceleration level measured directly on the vibrating surface as their reference criteria. This may not be sufficient to assess the risk of vibration exposure because coupling conditions at …

    ut-knoxville Repository record for Design and testing of [a] vibratory force measurement system for hand-arm vibration applications (opens in a new tab)

  9. Mechanical testing and evaluation of D3O® material for adequacy of an ergonomic intervention for vibration transmission reduction in aircraft manufacturing

    … to aircraft manufacturing sheet metal mechanics. ISO (5349-1, 2001b) indicates that symptoms of the hand-arm vibration syndrome, which may develop within 10 years of exposure, depends on the magnitude, frequency, and duration of vibration exposure and on his/her susceptibility. The American …

    wichita-thes Repository record for Mechanical testing and evaluation of D3O® material for adequacy of an ergonomic intervention for vibration transmission reduction in aircraft manufacturing (opens in a new tab)

  10. Human finger subjected to shock vibration loading

    … and are described by the international standard ISO 5349. The potential damage of exposure to higher frequencies is however not currently described by the standard and the human response of exposure is not known. Previous work has studied a 2D Finite Element model representing a human finger to …

    chalmers Repository record for Human finger subjected to shock vibration loading (opens in a new tab)

  11. Análise de impacto e risco de lesões no segmento superior associadas a execução da técnica de gyaku tsuki sobre makiwara por praticantes de karate do estilo shotokan

    … mesmo de acordo com as recomendações das normas ISO 2631 (1974 e 1997) e ISO 5349 (1986). Um dos acelerômetros foi fixado na porção distal do rádio e o outro acima da espinha da escápula. A disposição dos acelerômetros têm por objetivo captar o nível de vibração que efetivamente chega no segmento …

    brazil-ufrgs Repository record for Análise de impacto e risco de lesões no segmento superior associadas a execução da técnica de gyaku tsuki sobre makiwara por praticantes de karate do estilo shotokan (opens in a new tab)

  12. Evaluations Of Hand-Arm Vibration (Hav) Exposure And Related Vascular And Musculoskeletal Heath Effects Among Groundskeeping Workers In Southeastern U.S.

    … vascular, neurological, and musculoskeletal disorders, collectively known as hand-arm vibration syndrome (HAVS). However, concerns arise when adopting the currently available guidelines and standards to protect workers who regularly use vibrating tools due to the lack of standardized exposure …

    uab Repository record for Evaluations Of Hand-Arm Vibration (Hav) Exposure And Related Vascular And Musculoskeletal Heath Effects Among Groundskeeping Workers In Southeastern U.S. (opens in a new tab)

  13. Establishing a protocol for the measurement of human exposure to foot-transmitted vibration

    … measurement of occupational vibration exposure (ISO 2631-1, 1997; ISO 5349-1, 2001) do not provide appropriate guidance for FTV exposure measurement. Although several researchers have reported worker exposure to FTV, the reliabilities of the methods used to measure FTV have yet to be studied. The …

    laurentian Repository record for Establishing a protocol for the measurement of human exposure to foot-transmitted vibration (opens in a new tab)

  14. Kertészeti kisgépek rezgésterhelése és annak mérése = The vibration exposure of small horticultural tools and its reduction

    … gépkezelőt érő rezgésterhelés vizsgálata az ISO 5349:2001 szabvány alapján, illetve olyan tényezők meghatározása, amelyek hatással lehetnek a kezelőt érő rezgésterhelésre és befolyásolhatják a kézre ható rezgés mérési eredményének pontosságát. Másrészt különböző anti-vibrációs kesztyű rezgést …

    corvinus Download PDF for Kertészeti kisgépek rezgésterhelése és annak mérése = The vibration exposure of small horticultural tools and its reduction (opens in a new tab)

  15. VIBRATION EXPOSURE FROM BUCKING BARS DURING PERCUSSIVE RIVETING IN THE AEROSPACE INDUSTRY

    … was developed in order to absorb vibrations and isolate the operators from being exposed to high magnitude vibration. Third, 2 Boeing mechanics used 5 different bucking bar handles in order to install rivets on a test bench developed at the Boeing Advanced Research Center (BARC). The handles …

    washington Repository record for VIBRATION EXPOSURE FROM BUCKING BARS DURING PERCUSSIVE RIVETING IN THE AEROSPACE INDUSTRY (opens in a new tab)

  16. Development of a methodology for integrated performance analyses of anti-vibration gloves for controlling the hand-transmitted vibration

    … tools has been associated with an array of disorders of the hand-arm system, collectively referred to as the hand-arm vibration syndrome (HAVS). The risk of HAVS among hand-held power tools operators has been related to the nature of HTV exposure and the mechanical coupling of the hand with a …

    concordia Download PDF for Development of a methodology for integrated performance analyses of anti-vibration gloves for controlling the hand-transmitted vibration (opens in a new tab)

  17. X-Y-Z vibration amplitude risk assessment for 3/8" hobby grade hand-held electric drills based upon current occupational safety standards

    … hand-arm vibration safety standards in use: ISO 5349, ACGIH-TLV, and ANSI S3.34. Since the 1960's, numerous studies have been conducted for various commercial grade hand-held tools known to be associated with the disease. The majority of all reported tool testing has involved tools used by …

    ut-knoxville Repository record for X-Y-Z vibration amplitude risk assessment for 3/8" hobby grade hand-held electric drills based upon current occupational safety standards (opens in a new tab)