Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 19 of 19 for “"ISO 9693"”.

  1. Bond strength between veneer porcelains and CAD/CAM ceramic to CP titanium and evaluation of fracture load and effect of aging on low fusing porcelain fired over CP TI and CAD / CAM materials cemented onto CP TI

    … following the manufacturer’s instructions and ISO 9693 recommendations. Group 4, Vita Mark II blocks were sectioned into sixteen bars (8x3x1mm) and cemented with Multilink Implant cement (Ivoclar) on CP Ti bars. Fifteen specimens from each group were tested for bond strength by Schwickerath …

    bu Repository record for Bond strength between veneer porcelains and CAD/CAM ceramic to CP titanium and evaluation of fracture load and effect of aging on low fusing porcelain fired over CP TI and CAD / CAM materials cemented onto CP TI (opens in a new tab)

  2. Συγκριτική μελέτη αντοχής μεταλλοκεραμικού δεσμού κράματος Co-Cr και πορσελάνης αστρίου, με διαφορετικές μεθόδους κατασκευής του μεταλλικού υποστρώματος

    … σύμφωνα με τις προδιαγραφές που ορίζει το ISO 9693, τα οποία χωρίστη- καν σε δύο ομάδες: την ομάδα αναφοράς, τα μεταλλικά υποστρώματα της οποίας κα- τασκευάστηκαν με την τεχνική χύτευσης από κράμα βασικού μετάλλου Co-Cr (Wirobond C) και ομάδα ελέγχου, τα μεταλλικά υποστρώματα της οποίας …

    athens Repository record for Συγκριτική μελέτη αντοχής μεταλλοκεραμικού δεσμού κράματος Co-Cr και πορσελάνης αστρίου, με διαφορετικές μεθόδους κατασκευής του μεταλλικού υποστρώματος (opens in a new tab)

  3. Μελέτη της επίδρασης της επιφανειακής επεξεργασίας του μεταλλικού σκελετού στην αντοχή του μεταλλοκεραμικού δεσμού

    … σύμφωνα με τις προδιαγραφές που ορίζει το ISO 9693, τα οποία χωρίστηκαν σε δύο ομάδες: την Ομάδα 17, τα μεταλλικά υποστρώματα της οποίας κατασκευάστηκαν με την τεχνική χύτευσης από κράμα βασικού μετάλλουNi-Cr(KeralloyN Supreme) και την Ομάδα 16, τα μεταλλικά υποστρώματα της οποίας …

    athens Repository record for Μελέτη της επίδρασης της επιφανειακής επεξεργασίας του μεταλλικού σκελετού στην αντοχή του μεταλλοκεραμικού δεσμού (opens in a new tab)

  4. Einfluss der Oberflächenbehandlung von zinkhaltigen Goldlegierungen auf die Blasenbildung in Opakern

    … nach SCHWICKERATH gemäß DIN EN ISO 9693:2000 [1] unterzogen. Anschließend wurde die Keramik von den Plättchen durch Herunterbrechen vollständig entfernt. In der Aufsicht auf die Bruchfläche wurde der Bedeckungsgrad der anhaftenden Opakermasse auf der Legierung bestimmt. …

    fu-berlin Repository record for Einfluss der Oberflächenbehandlung von zinkhaltigen Goldlegierungen auf die Blasenbildung in Opakern (opens in a new tab)

  5. Effect of surface treatment on porcelain bond strength to titanium

    … following the manufacturer’s instructions and ISO 9693 recommendations, and tested for bond strength by Schwickerath crack initiation test (ISO 9693) using an Instron universal testing machine (Model: 5566A). The mode of failure and bond interface were evaluated by SEM / EDS. RESULTS: The mean …

    bu Repository record for Effect of surface treatment on porcelain bond strength to titanium (opens in a new tab)

  6. Einfluss der Dauer und der Temperatur von Oxidbränden auf die Verbundfestigkeit zwischen Keramik und EMF-Legierungen

    … Die zu Grunde liegende Prüfnorm ist die DIN EN ISO 9693. Abschließend wurde von jeder Serie an einem Plättchen im Längsschliff der Bruchspaltverlauf mit Hilfe eines Stereoauflichtmikroskops beurteilt. Bei den restlichen sechs Probekörpern wurden in der Aufsicht auf die Bruchflächen der …

    fu-berlin Repository record for Einfluss der Dauer und der Temperatur von Oxidbränden auf die Verbundfestigkeit zwischen Keramik und EMF-Legierungen (opens in a new tab)

  7. Συγκριτική μελέτη της αντοχής του μεταλλοκεραμικού δεσμού μεταξύ οδοντιατρικής πορσελάνης αστρίων και οδοντιατρικών κραμάτων Co-Cr με διαφορετικές τεχνικές κατασκευής των μεταλλικών υποστρωμάτων.

    … σύμφωνα με τις προδιαγραφές που ορίζει το ISO 9693, τα οποία χωρίστηκαν σε τέσσερεις ομάδες: την ομάδα αναφοράς, τα μεταλλικά υποστρώματα της οποίας κατασκευάστηκαν με την τεχνική χύτευσης από κράμα βασικού μετάλλου CoCr και τις ομάδες ελέγχου, τα μεταλλικά υποστρώματα των οποίων …

    athens Repository record for Συγκριτική μελέτη της αντοχής του μεταλλοκεραμικού δεσμού μεταξύ οδοντιατρικής πορσελάνης αστρίων και οδοντιατρικών κραμάτων Co-Cr με διαφορετικές τεχνικές κατασκευής των μεταλλικών υποστρωμάτων. (opens in a new tab)

  8. Μελέτη της αντοχής του μεταλλοκεραμικού δεσμού επί χυτών τιτανίου κάτω από διαφορετικές συνθήκες χύτευσης

    … not ground but only were sandblasted. The comparison was done with titanium castings produced in a special magnesium investment material and were treated under the normal conditions, which are suggested from the manufacturers.144 plastic patterns were produced of size little oversized of that of …

    greece Repository record for Μελέτη της αντοχής του μεταλλοκεραμικού δεσμού επί χυτών τιτανίου κάτω από διαφορετικές συνθήκες χύτευσης (opens in a new tab)

  9. Zahntechnische Bewertung einer Dentallegierung

    … metallkeramische Haftmechanismus wurde nach ISO 9693 geprüft. Im Biegeversuch nach Schwickerath wurden 18 Prüfkörper belastet, zwölf wurden zusätzlich einem 7- bzw 30-tägigen Korrosionstest ausgesetzt. Das Ergebnis im Vergleich zu anderen metallkeramischen Systemen ergab eine gute …

    freiburg-diss Repository record for Zahntechnische Bewertung einer Dentallegierung (opens in a new tab)

  10. Vergleichende Untersuchung zur Wirksamkeit eines Bonders in unterschiedlichen Cobalt-Chrom-basierten Metall-Keramik-Systemen bezüglich ihrer Temperaturwechsellastbeständigkeit

    … quantified. The main interests laid in the comparison between soft and hard cobalt-based alloys, as well as the possibly beneficial effects of a bonding agent. Furthermore, the effects of a higher wash-firing temperature, a slowed down cooling after firing and the storage in a corrosive solution …

    fu-berlin Repository record for Vergleichende Untersuchung zur Wirksamkeit eines Bonders in unterschiedlichen Cobalt-Chrom-basierten Metall-Keramik-Systemen bezüglich ihrer Temperaturwechsellastbeständigkeit (opens in a new tab)

  11. Einfluss von Mischungsverhältnis und Trocknungsphase der Grundmasse auf die Verbundfestigkeit zwischen edelmetallfreier Legierung und Verblendkeramik

    … gemäß den An-forderungen der in der DIN EN ISO 9693 [10] beschriebenen 3-Punkt-Biegescherprüfung nach SCHWICKERATH angefertigt. Das Aufbringen der deckenden Grundmasseschicht (Opaker) wurde dabei verschiedenen Modifikationen unterworfen. Die Grundmasse wurde hierfür wie folgt angemischt: • …

    fu-berlin Repository record for Einfluss von Mischungsverhältnis und Trocknungsphase der Grundmasse auf die Verbundfestigkeit zwischen edelmetallfreier Legierung und Verblendkeramik (opens in a new tab)

  12. Herstellung und Bewertung von elektrophoretisch abgeschiedenen keramischen 3D-Strukturen

    … nachgewiesen werden. Der Test nach ISO 9693-2 belegt, dass unter Anwendung des neuentwickelten Bonders zuerst die Verblendkeramik nachgibt, während der Haftverbund noch intakt ist. Somit konnte gezeigt werden, dass eine hierarchische Strukturierung von dreidimensionalen …

    fu-berlin Repository record for Herstellung und Bewertung von elektrophoretisch abgeschiedenen keramischen 3D-Strukturen (opens in a new tab)

  13. Einfluss des Lötens bzw. Laserschweißens auf die Verbundfestigkeit von Metall- Keramik-Systemen

    … 189 Prüfkörper wurden entsprechend DIN EN ISO 9693 angefertigt. Dies ergab aus drei Legierungen jeweils acht Serien mit wiederum jeweils sieben Prüfkörpern. Die Gerüste der ersten drei Serien blieben ungefügt: als Referenz, Gerüst nicht abgestrahlt bzw. Gerüst nicht gefräst. Drei weitere …

    fu-berlin Repository record for Einfluss des Lötens bzw. Laserschweißens auf die Verbundfestigkeit von Metall- Keramik-Systemen (opens in a new tab)

  14. Vergleichende Untersuchungen zum Verbund von Cobalt-Basis-Legierungen und Metall-Keramik-Verbundsystemen

    … 3 Punkt Biegeversuch nach SCHWICKERATH (DIN EN ISO 9693) zur Bestimmung der Verbundfestigkeit. Dazu wurden Prüfkörper hergestellt, welche sich in dem Weglassen und der Verwendung des Bonders NP Bond® (VITA) und in der Wahl einer festeren (Wirobond® 280) oder weniger festen Dentallegierung …

    fu-berlin Repository record for Vergleichende Untersuchungen zum Verbund von Cobalt-Basis-Legierungen und Metall-Keramik-Verbundsystemen (opens in a new tab)

  15. In-vitro-Untersuchungen zum Einfluss von Siliziumnitrid-Zwischenschichten auf den Titan-Keramik-Verbund

    … 3-Punkt Biegeschertest nach Schwickerath nach ISO 9693 durchgeführt. Die Prüfkörper wurden aus gegossenem Titan Grad 1 hergestellt und mit 120 µm Al2O3 gestrahlt. Als Vergleichserien wurden auf Prüfkörpern ohne zusätzliche Beschichtung die Titankeramiken nach Herstellervorschrift mit Bonder …

    fu-berlin Repository record for In-vitro-Untersuchungen zum Einfluss von Siliziumnitrid-Zwischenschichten auf den Titan-Keramik-Verbund (opens in a new tab)

  16. Vergleichende Untersuchungen zum SCHWICKERATH-Versuch, VOSS-Versuch und Abschrecktest

    … nach SCHWICKERATH (beschrieben als DIN EN ISO 9693), der VOSS-Versuch und der Abschrecktest. Die Prüfkörper wurden gemäß der Arbeitsempfehlung des jeweiligen Versuches und gemäß den Herstellerangaben gefertigt. Sieben verschiedene Legierungen der Firma BEGO, die alle auf dem Dentalmarkt …

    fu-berlin Repository record for Vergleichende Untersuchungen zum SCHWICKERATH-Versuch, VOSS-Versuch und Abschrecktest (opens in a new tab)

  17. Einfluss veränderter Parameter bei der Verblendung von edelmetallfreien Legierungen mit Keramik auf den Haftverbund

    … 3-Punkt Biegeschertest nach Schwickerath nach ISO 9693 durchgeführt. Die Ergebnisse wurden statistisch analysiert. Zusätzlich wurden die Mikromorphologie der Metall-Keramik-Kontaktzonen ausgewählter Prüfkörper mit dem Rasterelektronenmikroskop untersucht sowie EDX-Elementverteilungsanalysen …

    fu-berlin Repository record for Einfluss veränderter Parameter bei der Verblendung von edelmetallfreien Legierungen mit Keramik auf den Haftverbund (opens in a new tab)

  18. Vergleich verschiedener Prüfmethoden zur Bestimmung der Verbundfestigkeit zwischen einer Kobalt-Chrom-Legierung und einer Verblendkeramik

    … Drei-Punkt-Biegetest nach SCHWICKERATH (DIN EN ISO 9693), der VOSS- TEST, der Zugversuch nach PÜCHNER sowie ein Abschrecktest gewählt. Am Beispiel der aufbrennfähigen Kobalt-Chrom-Legierung WIROBOND C (BEGO, Bremen, Deutschland) und einer geeigneten Verblendkeramik OMEGA 900 (VITA, Bad …

    fu-berlin Repository record for Vergleich verschiedener Prüfmethoden zur Bestimmung der Verbundfestigkeit zwischen einer Kobalt-Chrom-Legierung und einer Verblendkeramik (opens in a new tab)

  19. Vergleichende Untersuchung zum Einfluss der Position des Brenngutes auf die Verbundfestigkeit

    … SCHWICKERATH-Test zum Einsatz, der in der DIN EN ISO 9693 [DIN, 2000] verankert ist und sich im deutschsprachigen Raum als geeignete Methode zur Bestimmung der Verbundfestigkeit durchgesetzt hat [DÖRFLER et al., 1995]. Alle ermittelten Scherverbundfestigkeitswerte, auch die, bei denen die …

    fu-berlin Repository record for Vergleichende Untersuchung zum Einfluss der Position des Brenngutes auf die Verbundfestigkeit (opens in a new tab)