Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 65 for “"Image Intensifier"”

  1. Application of gain-modulated image intensifier in biomedical imaging

    In recent years, the incorporation of image intensifiers into charge-coupled-device (CCD) devices has resulted in intensified CCD (ICCD) systems, which possess high sensitivity in low light conditions, as well as high temporal resolution. Such ICCD systems are typically used in fluorescence …

    nanyang Repository record for Application of gain-modulated image intensifier in biomedical imaging (opens in a new tab)

  2. INFORMATION TRANSFER EFFICIENCY OF X-RAY IMAGE INTENSIFIER-BASED IMAGING SYSTEMS.

    … and verified experimentally with an x-ray image intensifier (XRII)-based imaging system. In such a system, the DQE at low frequency range is primarily determined by the x-ray detection and scintillation processes at the CsI layer of the XRII. The effects of x-ray photon energy and sensor …

    arizona-thes Repository record for INFORMATION TRANSFER EFFICIENCY OF X-RAY IMAGE INTENSIFIER-BASED IMAGING SYSTEMS. (opens in a new tab)

  3. Image intensifier studies of low intensity triboluminescence, electroluminescence and photoluminescence of solids

    A four-stage magnetically focused image intensifier tube (IIT) with an optical power gain of about 106 was used in both spatial and spectral investigations of solids. The spectral studies involved the design and construction of a spectrograph to disperse light across the input photocathode of the …

    the-open-u Repository record for Image intensifier studies of low intensity triboluminescence, electroluminescence and photoluminescence of solids (opens in a new tab)

  4. Deconvolution of the point spread function of an x-ray image intensifier

    <p>Nondestructive Evaluation (NDE) is an interdisciplinary branch that is concerned with ensuring the quality and serviceability of materials and structures. The science of NDE incorporates the technology necessary for detection and measurement of significant properties, including discontinuities, …

    iastate Repository record for Deconvolution of the point spread function of an x-ray image intensifier (opens in a new tab)

  5. Software techniques for the aquisition of optical data from a minicomputer-based image-intensifier-vidicon system

    … The data acquisition system incorporates an image intensifier and vidicon tube in combination and is controlled by a minicomputer utilizing the described software. The software handles all control of the image-intensifier-vidicon system, acquires the data from the system, and stores the data …

    ut-knoxville Repository record for Software techniques for the aquisition of optical data from a minicomputer-based image-intensifier-vidicon system (opens in a new tab)

  6. Development of a full-field time-of-flight range imaging system

    A full-field, time-of-flight, image ranging system or 3D camera has been developed from a proof-of-principle to a working prototype stage, capable of determining the intensity and range for every pixel in a scene. The system can be adapted to the requirements of various applications, producing high …

    waikato-masters Repository record for Development of a full-field time-of-flight range imaging system (opens in a new tab)

  7. The development of a video-level controller for an ultra-violet intensified CCD camera

    … absolute intensity over a wide dynamic range. An image intensifier inside the camera converts the UV image into a visible image and the CCD camera transforms the visible image into a standard video signal. By controlling electrical inputs to the image intensifier, it is possible to vary the …

    ut-knoxville Repository record for The development of a video-level controller for an ultra-violet intensified CCD camera (opens in a new tab)

  8. Noise-limited performance of a hybrid detector and high-resolution display monitors.

    … two types of electronic devices. The first is an image intensifier/photomultiplier combination used in a laser communications receiver. The second type is high resolution display monitors to be used in digital radiology. The analysis of these devices centered on the influence of noise on their …

    arizona-thes Repository record for Noise-limited performance of a hybrid detector and high-resolution display monitors. (opens in a new tab)

  9. Development of the BigMIC image photon counting detector

    BigMIC is a large area image photon counting system that has been designed for applications in astronomy requiring the highest sensitivity and resolution such as echelle spectroscopy with very large telescopes. It consists of a 75 mm diameter image intensifier fibre-optically coupled to a fast …

    ucl Repository record for Development of the BigMIC image photon counting detector (opens in a new tab)

  10. Electron Optical Study of a Secondary Electron Multiplier

    … structure of an electron multiplier for an image intensifier. A special structure satisfying production requirements was studied. Electron optical calculations consisted of determining the potential distribution and tracing the electron trajectories. Liebmann's procedure was used to solve …

    portland-state Repository record for Electron Optical Study of a Secondary Electron Multiplier (opens in a new tab)

  11. Some effects of excitation time on phosphor decay time

    … the observed shortcomings of a particular image intensifier tube using a P-11 phosphor.

    alabama Repository record for Some effects of excitation time on phosphor decay time (opens in a new tab)

  12. Developmental testing of a prototype all-reflection Michelson interferometer

    … elements was discovered, and the efficacy of an image intensifier/photodiode array combination for use as a detector was verified. The feasibility of the interferometer design was verified by the observation of interference fringes using mercury 5461 A light. A practical instrument would be …

    nps Repository record for Developmental testing of a prototype all-reflection Michelson interferometer (opens in a new tab)

  13. Innovations in beam-foil spectroscopy : emission spectra of nitrogen

    … Spectrograph by a Two Stage Cascade Image Intensifier (RCA Model C33034) is presented. The results show that these two innovations greatly increase the efficiency of the spectra gathering system. A survey of the beam-foil excited emission spectra obtained from nitrogen ions (N+) …

    rice Repository record for Innovations in beam-foil spectroscopy : emission spectra of nitrogen (opens in a new tab)

  14. The direct measurement of system Modulation Transfer Function (MTF) for an AN/AVS-6 Aviator's Night Vision Imaging System (ANVIS)

    … imaging systems such as the lenses and the image intensifier tube. The current method for calculating the system MTF is to combine the MTFs of all the components of the imaging system. Little research has been performed to directly measure the MTF of the entire system. This thesis describes …

    vt Repository record for The direct measurement of system Modulation Transfer Function (MTF) for an AN/AVS-6 Aviator's Night Vision Imaging System (ANVIS) (opens in a new tab)

  15. A quantitative analysis of ionising radiation exposure to the hands, thyroid and whole body of orthopaedic registrars at King Edward VIII Hospital during fluoroscopic internal fixation of the lower limbs

    The portable C-arm image intensifier has been of great value to orthopaedic registrars for many years. One of its common uses in trauma surgery is during controlled reduction of long bone fractures and accurate placement of internal or external fixation devices. Ionising radiation has therefore …

    dut Repository record for A quantitative analysis of ionising radiation exposure to the hands, thyroid and whole body of orthopaedic registrars at King Edward VIII Hospital during fluoroscopic internal fixation of the lower limbs (opens in a new tab)

Page 1 of 4