Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 25 for “"Image Processing, Computer-Assisted"”.

  1. Structural Basis for Coordination in Dimeric Kinesin

    … Ruby-Helix, was developed to facilitate helical image analysis and implement a new algorithm for the analysis of helical objects with a seam. Ruby-Helix incorporates several new techniques for conventional helical analysis, and automates many of the repetitive steps involved in helical analysis, …

    utswmed Repository record for Structural Basis for Coordination in Dimeric Kinesin (opens in a new tab)

  2. Development of Applications and Quantitative Frameworks for Multispectral Optoacoustic Tomography

    … a transparent and open-source toolbox for image reconstruction and analysis along with its deployment to a cloud-based workflow service managed by the University of Texas Southwestern Medical Center at Dallas' BioHPC; a simple and scalable method to address spectral aliasing and improve the …

    utswmed Repository record for Development of Applications and Quantitative Frameworks for Multispectral Optoacoustic Tomography (opens in a new tab)

  3. An Optical Flow Based Methodology for Visualizing Dynamic Sucellular [sic] Organiztion [sic] Demonstrated Through Profilin and Rho GTPase Microdomains

    … on existing optical flow based non-linear image registration we developed an approach to remap a migrating cell to a common cell footprint while preserving the characteristics of our signal of interest at a spatial granularity necessary for understanding micron scale biological …

    utswmed Repository record for An Optical Flow Based Methodology for Visualizing Dynamic Sucellular [sic] Organiztion [sic] Demonstrated Through Profilin and Rho GTPase Microdomains (opens in a new tab)

  4. Confocal laser endomicroscopy in coeliac disease

    … in vivo histological analysis. Although computer-aided diagnosis (CAD) has been studied in different medical imaging techniques including computed tomography (CT), magnetic resonance imaging (MRI) and histology slides, its role has not yet been established for CLE images. Aims and methods …

    unsw Repository record for Confocal laser endomicroscopy in coeliac disease (opens in a new tab)

  5. Novel Detection Methods for Chemical Exchange and Application to Breast Cancer Imaging

    Chemical exchange saturation transfer (CEST) is a novel contrast mechanism that is based on the chemical exchange processes between the protons in water and solutes. CEST can indirectly detect the low concentrated solutes, which are not observable with conventional MRI and indicate the quantitative …

    utswmed Repository record for Novel Detection Methods for Chemical Exchange and Application to Breast Cancer Imaging (opens in a new tab)

  6. Deep Learning-Based Comprehensive Pathology Image Analysis

    … great tools for the analysis of histopathology images. Deep learning algorithms can aid in the routine diagnostics and have the potential to extract hidden information directly from slide images, providing valuable information for healthcare professionals. This dissertation applied deep learning …

    utswmed Repository record for Deep Learning-Based Comprehensive Pathology Image Analysis (opens in a new tab)

  7. Computer Vision to Characterize Protein Interactions at the Cell Membrane

    … characterize interactions as advances progress. Computer vision tools offer a powerful approach to automate analysis, overcoming limitations of manual analysis to optimize the discovery of novel interactions and their underlying mechanisms. In this thesis, I develop novel computer vision tools to …

    utswmed Repository record for Computer Vision to Characterize Protein Interactions at the Cell Membrane (opens in a new tab)

  8. Harmonic source wavefront aberration correction for ultrasound imaging.

    … quality in a significant number of ultrasound images. Previous aberration correction studies have focused on development of aberration estimation algorithms or on aberration reduction by using harmonic imaging. In the past, a major drawback of aberration estimation algorithms has been the …

    duke Repository record for Harmonic source wavefront aberration correction for ultrasound imaging. (opens in a new tab)

  9. Quantitative Analysis of the Spatial and Temporal Organization of Cell Surface Receptors

    … in live cells, motivating the development of image analysis tools to quantitatively characterize the spatiotemporal organization of signaling molecules. In this thesis, I describe the development of a conditional colocalization analysis algorithm designed to explore the interaction network of …

    utswmed Repository record for Quantitative Analysis of the Spatial and Temporal Organization of Cell Surface Receptors (opens in a new tab)

  10. Comprehensive Analysis of Lung Cancer Prognostic Factors

    … in tumor level, deep learning aided pathology image analysis was used to extract tumor geometry and microenvironment features, upon which an image-based survival prediction model was built and independently validated for lung adenocarcinoma. Second, in patient level, a nomogram was built with …

    utswmed Repository record for Comprehensive Analysis of Lung Cancer Prognostic Factors (opens in a new tab)

  11. Evaluation of the Treatment Effects of the Functional Regulator of Fränkel in the Correction of Angle Class II Malocclusions

    One of the greatest challenges an orthodontist faces is the correction of Angle Class II malocclusions. Several different treatment options are available to correct saggital jaw discrepancies that often exist in these individuals. Traditionally, headgear has been used to restrain forward maxillary …

    iupui Repository record for Evaluation of the Treatment Effects of the Functional Regulator of Fränkel in the Correction of Angle Class II Malocclusions (opens in a new tab)

  12. Motion Estimation and Motion-Compensated Reconstruction for Four-Dimensional Cone Beam Computed Tomography (4D-CBCT)

    … is not optimal for tumor localization due to low image quality caused by insufficient number of projections located in each phase after the projection binning according to respiration phases. The specific aims of this dissertation research are to: 1) improving the accuracy of inter-phase motion …

    utswmed Repository record for Motion Estimation and Motion-Compensated Reconstruction for Four-Dimensional Cone Beam Computed Tomography (4D-CBCT) (opens in a new tab)

  13. Robust Fat and Fluid Suppression in MR Imaging: Technical Developments and Advanced Clinical Applications

    … generate simultaneous fat and fluid suppressed images of the cervical spines in a single acquisition. It can also simultaneously generate the standard T2-weighted image, fluid suppressed image and myelogram, significantly reducing the total scan time compared to the current clinical protocols. …

    utswmed Repository record for Robust Fat and Fluid Suppression in MR Imaging: Technical Developments and Advanced Clinical Applications (opens in a new tab)

  14. Bilateral Ortohogonality Generative Acquisitions Method for Transmit Field Inhomogeneity Correction in Magnetic Resonance Imaging

    … utilized for acquisition of high-resolution images and reducing scan time. However, transmit field inhomogeneity of ultra-high field systems, present an obstacle for widespread clinical utilization. In literature, radiofrequency pulse design and multi-acquisition methods with and without …

    utswmed Repository record for Bilateral Ortohogonality Generative Acquisitions Method for Transmit Field Inhomogeneity Correction in Magnetic Resonance Imaging (opens in a new tab)

  15. Improving Cone-Beam Computed Tomography Based Adaptive Radiation Therapy with Deep Learning

    … challenge involves generating synthetic CT (sCT) images that retain CBCT anatomy while maintaining CT image quality. Clinically used sCT is typically obtained through deformable image registration (DIR) between pre-planning CT (pCT) and CBCT; however, this method often inadequately preserves CBCT …

    utswmed Repository record for Improving Cone-Beam Computed Tomography Based Adaptive Radiation Therapy with Deep Learning (opens in a new tab)

  16. An Imaging Approach to Examine Telomere Dynamics and Regulation of Gene Expression with Aging

    Telomeres are repetitive non-coding nucleotide sequences (TTAGGG)n capping the ends of chromosomes. Improved methods to measure the shortest (not just average) telomere lengths (TLs) are needed. Progressive telomere shortening with increasing age has been associated with shifts in gene expression …

    utswmed Repository record for An Imaging Approach to Examine Telomere Dynamics and Regulation of Gene Expression with Aging (opens in a new tab)

  17. Automated Quantification of Image-Derived Phenotypes and Integration with the Electronic Health Record at Scale in an Academic Biobank

    BACKGROUND: Radiographic images obtained during clinical care can yield a tremendous number of quantitative traits that facilitate translational research. Both liver fat and abdominal adipose mass are examples of quantitative traits that are highly relevant to human health and disease and can be …

    utswmed Repository record for Automated Quantification of Image-Derived Phenotypes and Integration with the Electronic Health Record at Scale in an Academic Biobank (opens in a new tab)

  18. The Accuracy of Computer Video Imaging Prediction : Just Prior to Surgical Mandibular Advancement/Genioplasty Orthognathic Cases

    The accuracy of the computer video imaging treatment prediction was investigated using Quick Ceph Image.™ Thirty one surgical mandibular advancement/genioplasty orthognathic cases were examined to determine if the soft tissue profile prediction was representative of the actual result. All patients …

    loma-linda Repository record for The Accuracy of Computer Video Imaging Prediction : Just Prior to Surgical Mandibular Advancement/Genioplasty Orthognathic Cases (opens in a new tab)

  19. Evaluation of Apical, Coronal and Occlusal Form Diffrences with Conventional Orthodontic Treatment

    … subjects were selected on their respective CBCT images at two time points: pre-orthodontic treatment (T1) and post-orthodontic treatment (T2). Comparisons were made between the two time points to evaluate how each arch form changed following routine orthodontic treatment. Statistical Analysis: …

    loma-linda Repository record for Evaluation of Apical, Coronal and Occlusal Form Diffrences with Conventional Orthodontic Treatment (opens in a new tab)

  20. Orthodontic Mini-Implant Failure: Assessing the Relationship to Bone Quality Using QCBCT

    The purpose of this study was to evaluate the cortical bone thickness (mm), cortical bone density (HU), and trabecular bone density (HU) of mini-implants sites in both the maxilla and mandible using QCBCT to determine if they had any effect on mini-implant failure rate. Patient characteristics …

    loma-linda Repository record for Orthodontic Mini-Implant Failure: Assessing the Relationship to Bone Quality Using QCBCT (opens in a new tab)

Page 1 of 2