Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 18 of 18 for “"Image-Guided radiotherapy (IGRT)"”

  1. Clinical symptoms and volumetric radiological responses of acoustic neuroma patients, treated with hypo-fractionated image guided radiotherapy (IGRT) at Groote Schuur hospital between 2013 and 2016

    … patients treated with fractionated stereotactic radiotherapy (SRT) using photons. We describe clinical and radiological outcomes of AN patients treated with SRT at an academic centre in Cape Town, South Africa. Objectives: To describe patient demographics, tumour characteristics and patients’ …

    cape-town Repository record for Clinical symptoms and volumetric radiological responses of acoustic neuroma patients, treated with hypo-fractionated image guided radiotherapy (IGRT) at Groote Schuur hospital between 2013 and 2016 (opens in a new tab)

  2. Image quality and dose of an accelerator-integrated kV CBCT systems

    … about tumor position is critical in the radiotherapy process. As image-guided radiotherapy (IGRT) becomes more popular in radiation treatment, its overall quality and performance, such as the image quality and amount of dose delivered, need to be assessed. The research described in this …

    laurentian Repository record for Image quality and dose of an accelerator-integrated kV CBCT systems (opens in a new tab)

  3. Real-time tumor localization with electromagnetic transponders for image-guided radiotherapy applications

    … of treatment errors, is a remaining challenge in radiotherapy. A novel technology for the dynamic monitoring of tumor motion uses tumor-implanted electromagnetic (EM) transponders. In the present thesis, concepts and strategies for the use of the EM technology in image-guided radiotherapy (IGRT) …

    heid-diss Repository record for Real-time tumor localization with electromagnetic transponders for image-guided radiotherapy applications (opens in a new tab)

  4. A Method for Online Dose Prediction for Image Guided Proton Therapy

    … the time-scale of pa- tient setup during proton image guided radiotherapy (IGRT). We hypothesized that a com- parative analysis of a reference CBCT (RefCBCT) matching the anatomy of a treatment planning CT (TPCT) and a secondary CBCT (SecCBCT) taken as part of an IGRT setup sequence could be used …

    gatech Repository record for A Method for Online Dose Prediction for Image Guided Proton Therapy (opens in a new tab)

  5. Evaluation of Deformable Image Registration For Improved 4D Ct-Derived Ventilation For Image Guided Radiotherapy

    … studies have demonstrated the use of physiologic images in radiation therapy treatment planning to identify regions for functional avoidance. This image-guided radiotherapy (IGRT) strategy may reduce the injury and/or functional loss following thoracic radiotherapy. 4D computed tomography (CT), …

    uthsc Repository record for Evaluation of Deformable Image Registration For Improved 4D Ct-Derived Ventilation For Image Guided Radiotherapy (opens in a new tab)

  6. Quantification of geometric uncertainties in image guided radiotherapy

    … uncertainties that are introduced into the image guided radiotherapy (IGRT) process by Cone Beam CT (CBCT) based IGRT equipment are sufficiently small that they do not pose a significant risk of geometrical error in treatment delivery. This was performed by quantifying and investigating the …

    whiterose Repository record for Quantification of geometric uncertainties in image guided radiotherapy (opens in a new tab)

  7. Deformable models for adaptive radiotherapy planning

    Radiotherapy is the most widely used treatment for cancer, with 4 out of 10 cancer patients receiving radiotherapy as part of their treatment. The delineation of gross tumour volume (GTV) is crucial in the treatment of radiotherapy. An automatic contouring system would be beneficial in radiotherapy …

    edinburgh Repository record for Deformable models for adaptive radiotherapy planning (opens in a new tab)

  8. Dosimetric investigation of image-guided radiotherapy for prostate cancer using cone-beam computed tomography

    Objectives: 1. To survey the current practice of image-guided radiotherapy (IGRT) for prostate cancer in the United Kingdom. 2. To validate a practical dose calculation strategy on cone-beam computed tomography (CBCT) 3. To assess the effect of CBCT verification imaging frequency on actual dose …

    ucl Repository record for Dosimetric investigation of image-guided radiotherapy for prostate cancer using cone-beam computed tomography (opens in a new tab)

  9. Development and Evaluation of the Volumetric Image-Matching Environment for Radiotherapy (VIMER) Thesis

    … Development and Evaluation of the Volumetric ImageMatching Environment for Radiotherapy (VIMER) submitted by Brook Kennedy Byrd A novel 3D immersive virtual environment (3D IVE) image matching application, referred to as the VIMER ( V olumetric I mage M atching E nvironment for R adiotherapy), …

    liverpool Repository record for Development and Evaluation of the Volumetric Image-Matching Environment for Radiotherapy (VIMER) Thesis (opens in a new tab)

  10. Καθορισμός των αποκλίσεων τοποθέτησης ασθενών που υποβάλλονται σε καθοδηγούμενη από εικόνα/ανά συνεδρία ακτινοθεραπεία

    … assessment of patient setup errors during image-guided radiotherapy (IGRT), through the systematic recording and analysis of data from two imaging modalities: cone-beam computed tomography (CBCT) and planar kV imaging, focusing on four main anatomical sites—prostate, head and neck, lung, …

    greece Repository record for Καθορισμός των αποκλίσεων τοποθέτησης ασθενών που υποβάλλονται σε καθοδηγούμενη από εικόνα/ανά συνεδρία ακτινοθεραπεία (opens in a new tab)

  11. Generative AI for cone-beam CT dose reduction and intensity correction in adaptive radiotherapy

    In image-guided radiotherapy (IGRT), cone-beam computed tomography (CBCT) is used to align patients in the treatment position. CBCT scans administer radiation exposure and subject patients to secondary cancer risk. However, lowering CBCT imaging dose continues to be challenging as the image quality …

    lmu-germany Repository record for Generative AI for cone-beam CT dose reduction and intensity correction in adaptive radiotherapy (opens in a new tab)

  12. Developing Lower Cost Radiotherapy Solutions for Low and Middle Income Countries

    Radiotherapy research often focuses on state-of-the-art methods to provide small improvements in the treatment of patients in high-income countries, while less focus is put on providing low-cost treatments suitable for the majority of people in the world who have little or no access to …

    uvic Repository record for Developing Lower Cost Radiotherapy Solutions for Low and Middle Income Countries (opens in a new tab)

  13. Modelling geometric uncertainties in prostate radiotherapy

    Image guided radiotherapy (IGRT) presents a range of techniques to enhance thegeometric accuracy of radiotherapy treatment. A full evaluation of such techniques,against increased cost, workload, or unnecessary radiation dose, would require theincorporation of geometric errors into existing methods …

    salford Repository record for Modelling geometric uncertainties in prostate radiotherapy (opens in a new tab)

  14. Modelling geometric uncertainties in prostate radiotherapy

    Image guided radiotherapy (IGRT) presents a range of techniques to enhance thegeometric accuracy of radiotherapy treatment. A full evaluation of such techniques,against increased cost, workload, or unnecessary radiation dose, would require theincorporation of geometric errors into existing methods …

    salford Repository record for Modelling geometric uncertainties in prostate radiotherapy (opens in a new tab)

  15. Clinical reasoning in image guided radiotherapy: A multimethod study

    Introduction 3D Image Guided Radiotherapy (IGRT) using cone beam computer tomography has been implemented into the UK over the last decade. There is evidence to suggest that the training of therapeutic radiographers and the development of departmental processes may not have kept pace with the …

    sheffield-hallam Repository record for Clinical reasoning in image guided radiotherapy: A multimethod study (opens in a new tab)

  16. Applications of cone beam computed tomography in radiotherapy treatment planning.

    In recent years Image-Guided Radiotherapy (IGRT) has experienced many technical advances. One of the most significant has been the widespread implementation of kilovoltage imagers attached to the gantry of linear accelerators (LINACs); these units are capable of 2D planar imaging, fluoroscopy and …

    adelaide Repository record for Applications of cone beam computed tomography in radiotherapy treatment planning. (opens in a new tab)

  17. Surface guided radiotherapy

    Modern radiotherapy aims to treat the decease while minimizing the radiation dose to the adjacent normal tissue, to minimize acute and late effects of the treatment. The foremost technological approaches have been intensity modulated radiotherapy (IMRT) and intensity modulated proton therapy (IMPT) …

    lund Repository record for Surface guided radiotherapy (opens in a new tab)

  18. Segmentation automatique des images de tomographie conique pour la radiothérapie de la prostate

    … (CBCT) pour la radiothérapie guidée par l’image, éventuellement adaptative, présente certaines difficultés en raison du faible contraste et du bruit important dans les images pelviennes. L’objectif principal de cette thèse est d’apporter des contributions méthodologiques pour le recalage …

    star-france Repository record for Segmentation automatique des images de tomographie conique pour la radiothérapie de la prostate (opens in a new tab)