Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 13 of 13 for “"Image-guide"”.
-
Advancement of fiber image guide based snapshot imaging spectrometer technology for bioimaging and environmental applications
… of raw data into decipherable hyperspectral images and spectra. Previous implementations of fiber based imaging spectrometers were focused on breadboard proof of concept designs and were not optimized for field imaging. This thesis details the development of two generations of imaging …
-
Multiplexing for DMD-Based Near-to-Eye Displays
… often involves an angular bandwidth limited image guide employing Total Internal Reflection (TIR) due to material refractive index constraints. This bottlenecks to packaging size and couples it to the Field of View (FOV) and resolution. Previous architectures have focused on physically …
-
Development of cancer screening technologies for imaging nuclear morphology across a large field-of-view
… cervical CAncer Screening Patch (CASP) that can image across the entire epithelium of cervical tissue (~25 mm diameter FOV) without sacrificing the ability to resolve subcellular features. The system utilizes an epifluorescence microscope coupled to a custom-machined, high-resolution polymer …
-
The Design, Fabrication, and Calibration of a Fiber Filter Spectrometer
… is created by coating the ends of a fiber optic image guide (FIG) with a spectral filter, the FIG is then coupled to a detector array. Using the FIG as the spectral filter substrate reduces the optical crosstalk to the point that it is inconsequential. This work describes the modeling, …
-
Towards the development of an all-optical, non-contact, photon absorption remote sensing (PARS) endomicroscope for blood vasculature imaging
… prototype designs were developed using image guide fiber (IGF) technology and achromatic graded-index (GRIN) lenses, with systematic de-risking experiments guiding their evolution. The first prototype (P1) achieved a resolution of ~1 µm and signal-to-noise ratio (SNR) of 22 dB, …
-
Development of ultrasound elastography methods for biomechanical assessment of soft tissues in medical diagnosis
… diagnosis, treatment monitoring as well as image-guide therapy. Elastography is normally implemented with the assistance of conventional medical imaging methods such as ultrasound, magnetic resonance imaging, and optical coherence tomography. Ultrasound-based elastography as a safe, low-cost …
-
Waveguide-based antenna arrays in multi-chip module technology
For mm-waves, two types of low-loss waveguide are analysed, designed and measured. One is the hollow substrate integrated waveguide (HSIW) in which the inner dielectric of a traditional substrate integrated waveguide (SIW) is removed to resemble the propagation characteristics of a standard …
-
High-resolution imaging for cancer detection with a fiber bundle microendoscope
… system based on a fiber optic bundle image guide. In combination with a topical fluorescent dye, the fiber bundle can be placed into contact with the tissue to be observed. A high-resolution image is then projected onto a CCD camera and stored on a PC. A pilot study was performed on …
-
Registration of Real-time and Prior Images for MRI-guided Cardiac Interventions
… application of interest is the use of MRI to guide an interventional catheter into the left ventricle (LV), and applying radio-frequency (RF) energy to eliminate the anatomical substrates responsible for ventricular tachycardia. However, interventional guidance with MRI is not without its own …
-
A New Silicon-Based Dielectric Waveguide Technology for Millimeter-Wave/Terahertz Devices and Integrated Systems
… this research is to develop a novel silicon waveguide-based technology for implementing various structures and devices in the mmWave and THz range of frequencies. The structures introduced in this study are designed based on High Resistivity Silicon (HRS). Two technologies are developed and …
-
Synergic control in MIG welding and penetration control in TIG welding
… pulse current period, by means of a fibre optics image guide/video camera/microcomputer based controller. The system has been found to be capable of controlling the weld bead penetration uniformly in stainless steel plates and joints, for constant as well as variable material thicknesses. However, …
-
Development of Low-cost Imaging Tools for Screening of Retinal Biomarkers in Alzheimer’s Disease
… in dysplastic tissue. The use of OCT as image guidance for a/LCI can strengthen the technique, providing sample orientation as well as retinal layer segmentation to pinpoint a/LCI measurements. The dissertation starts with the development and clinical application of a low-cost OCT system. …
-
Image-Guided Robotic Dental Implantation With Natural-Root-Formed Implants
… models which are reconstructed from Cone-beam CT images. An innovative image-guided robotic site-preparation system for implants insertion is designed and implemented. The preoperative plan of the implant insertion is transferred into intra-operative operations of the robot using a two-step …