Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 39 for “"Image-guided radiotherapy"”.
-
Image guided radiotherapy in breast cancer
Advances in radiotherapy allow for highly conformal treatment, however, image guidance is required to account for setup uncertainties. Breast radiotherapy has had simplified imaging requirements compared with other tumour sites. In this thesis, various aspects of the evolution of image guidance in …
-
Advancements in Magnetic Resonance Image Guided Radiotherapy
Magnetic resonance image guided radiation therapy (MRgRT) devices are a recently developed technology that integrate the excellent soft tissue contrast and real-time imaging capabilities of MRI with a medical linear accelerator (Linac). This provides an unprecedented ability to guide and adapt …
-
Quantification of geometric uncertainties in image guided radiotherapy
… uncertainties that are introduced into the image guided radiotherapy (IGRT) process by Cone Beam CT (CBCT) based IGRT equipment are sufficiently small that they do not pose a significant risk of geometrical error in treatment delivery. This was performed by quantifying and investigating the …
-
Clinical reasoning in image guided radiotherapy: A multimethod study
Introduction 3D Image Guided Radiotherapy (IGRT) using cone beam computer tomography has been implemented into the UK over the last decade. There is evidence to suggest that the training of therapeutic radiographers and the development of departmental processes may not have kept pace with the …
-
On-treatment image-guided radiotherapy for central lung tumours
… with conventional or high dose per fraction radiotherapy regimens due to abutting and overlapping radiosensitive organs-at-risk. Using two patient cohorts, this thesis explores the scope of isotoxic dose escalation possible for central lung tumours due to new techniques now technically …
-
The optimization of image guided radiotherapy in lung cancer
… involved the assessment and analysis of multiple images belonging to 100 patients. This allowed progression onto the next project which was assessment of the optimal safe method of delineation of 4DCT. The most efficient method was compared to gold standard. At this point a different aspect of the …
-
Automatic Block-Matching Registration to Improve Lung Tumor Localization During Image-Guided Radiotherapy
… are dedicated to minimizing uncertainties in radiotherapy. This enables the isotoxic delivery of escalated tumor doses, leading to better local tumor control. The current dissertation specifically addresses inter-fractional uncertainties resulting from patient setup variability. An automatic …
-
Evaluation of Deformable Image Registration For Improved 4D Ct-Derived Ventilation For Image Guided Radiotherapy
… studies have demonstrated the use of physiologic images in radiation therapy treatment planning to identify regions for functional avoidance. This image-guided radiotherapy (IGRT) strategy may reduce the injury and/or functional loss following thoracic radiotherapy. 4D computed tomography (CT), …
-
Image quality and dose of an accelerator-integrated kV CBCT systems
… about tumor position is critical in the radiotherapy process. As image-guided radiotherapy (IGRT) becomes more popular in radiation treatment, its overall quality and performance, such as the image quality and amount of dose delivered, need to be assessed. The research described in this …
-
Vergleich der Akuttoxizitäten von Patienten mit Prostatakarzinom bei definitiver Radiatio mit unterschiedlichen Strahlentherapieverfahren
… Therapieverfahren der IMRT (Intensity Modulated Radiotherapy) bei kurativer Bestrahlung von Patienten mit Prostatakarzinom hinsichtlich der auftretenden Akuttoxizitäten, wobei zwei IMRT-Geräte über eine zusätzliche bildgeführte Therapie (IGRT - Image Guided Radiotherapy) verfügen und ein Gerät …
-
Ultrasound Imaging with Flexible Array Transducer
Ultrasound imaging has been developed for image-guided radiotherapy for tumor tracking, and the flexible array transducer is a promising tool for this task. It can reduce the user dependence and anatomical changes caused by the traditional ultrasound transducer. However, due to its flexible …
-
Towards Active Image Guidance in X-ray Fluoroscopy-guided Radiotherapeutic and Surgical Interventions
… ionizing dose delivered during x-ray fluoroscopy-guided minimally invasive clinical procedures, particularly in interventional cardiology and neuroradiology, and in real-time tumor tracking radiotherapy and radiosurgery. As these image-guided procedures advance and become more complex, the …
-
Feasibility Evaluation of the Use of Gold Nanoparticles as Theragnostic Agents for Personalized and Precision Radiotherapy
Gold nanoparticles arouse a special interest in radiotherapy. Multiple studies have already shown their potential use as diagnostic and therapeutic agents. In diagnostics they can be used as contrast agents, while in therapy they could act as dose enhancers and radiosensitizers. The purpose of this …
-
A Method for Online Dose Prediction for Image Guided Proton Therapy
… the time-scale of pa- tient setup during proton image guided radiotherapy (IGRT). We hypothesized that a com- parative analysis of a reference CBCT (RefCBCT) matching the anatomy of a treatment planning CT (TPCT) and a secondary CBCT (SecCBCT) taken as part of an IGRT setup sequence could be used …
-
A Measure of Voxel Similarity for Improving the Image-based Quantification of Tissue Structure and Function
… assessment is a key component in adaptive image-guided radiotherapy. Conventional anatomic measures of response offer little information about the spatial distribution of tumor change. Recently developed voxel-wise response assessment methods operating on functional and biological imaging …
-
Deformable models for adaptive radiotherapy planning
Radiotherapy is the most widely used treatment for cancer, with 4 out of 10 cancer patients receiving radiotherapy as part of their treatment. The delineation of gross tumour volume (GTV) is crucial in the treatment of radiotherapy. An automatic contouring system would be beneficial in radiotherapy …
-
Machine Learning Framework to Reduce Patient-Reported Dysphagia in Head and Neck Radiotherapy
Radiotherapy treatment has become more effective in the 21st century due to advancements in treatment technologies such as image-guided radiotherapy and volumetric modulated arc therapy. Machine learning algorithms can provide advanced analytics based on the clinical, imaging, and dosimetric data …
-
Novel techniques for registration of multimodal medical images
Medical image registration is a critical image processing task in many applications such as image-guided surgery (IGS) and image-guided radiotherapy. Herein, a novel automatic inter-modal affine registration technique is proposed based on the correlation ratio (CR) similarity metric firstly. The …
Page 1 of 2