Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 20 of 32 for “"Imaging Condition"”
-
Suppressing Near-surface Reverse Time Migration Artifacts Using a Band-selecting Imaging Condition
… paper, I introduce a frequency band-selecting imaging condition for Reverse Time Migration (RTM) of shallow reflection datasets which effectively eliminates artifacts that are problematic on near-surface reflection sections. Within the classically defined near-surface region of the subsurface, …
-
Elastic wavefield migration and tomography
… In my thesis, I apply popular wavefield imaging and tomography to elastic media, and propose methods to address challenges posed by elastic multicomponent wavefields and multiparameter models. The key novelty of my research consists of new elastic imaging conditions, which generate …
-
Wavefield imaging using the energy norm
… energy norm} that is applicable to wavefield imaging. Extending the concept of the norm to an inner product, one can compare two related wavefields. Therefore, an imaging condition can be defined as the inner product between the source and receiver wavefields at every spatial location. In this …
-
A generalized Kirchhoff-WKBJ depth migration theory for multi-offset seismic reflection data : reflectivity model construction by wavefield imaging and amplitude estimation
… and quantitative investigation into the imaging and amplitude estimation of subsurface earth reflectivity structure within the framework of pre stack wave-equation depth migration of multi-offset seismic reflection data. Analysis is performed on five prestack depth migration reflectivity …
-
Elastic Reverse-Time Migration Imaging Using Perforation Shots and Vertical Receiver Arrays
… a kernel component in a reverse-time migration imaging condition. A 2-D fourth order spatially accurate finite-difference solution to the elastic-wave equation is implemented to model wave propagation in elastic media resulting from a variety of focal-mechanism types and orientations. This …
-
Elastic time-reverse imaging and transmission tomography for microseismic and DAS VSP data
… of this assumption is that conventional acoustic imaging algorithms generally use single-component P-wave data and thus do not account for multicomponent elastic (P- and S-mode) data that can provide additional subsurface information such as fracture distributions and elastic properties. To …
-
Wave propagation in complex media, scattering theory, and application to seismic imaging
Migration is a seismic imaging method that consists of creating a representation of the Earth's subsurface structure from the recording of seismic waves. Migration is essentially equivalent to solving an inverse scattering problem in structurally complex media. Conventional migration algorithms …
-
INVESTIGATING THE MECHANISM OF BACTERIAL CELL DIVISION WITH SUPERRESOLUTION MICROSCOPY
… an empirical criterion to evaluate whether an imaging condition is appropriate for accurate superresolution image reconstruction. Both the threshold selection method and imaging condition criterion are easy to implement within existing PALM clustering algorithms and experimental conditions.
-
Surface Plasmon Fluorescence Microscopy: Characteristics and Application to Bioimaging
The imaging characteristics of a widefield surface plasmon fluorescence microscope are studied. It is shown through modeling as well as experiments that the microscope has a donut-shaped point spread function. To mitigate the poor imaging condition arising from this, an optical method of adding …
-
Detection and identification of converted modes and source independent converted phase imaging : Groningen, The Netherlands
… of using the Source Independent Converted Phase Imaging method to image the position in the subsurface where these phases have been generated. We examine the limitations of that method for imaging the position of shallow interfaces such as the ones at Groningen. The station spacing required to …
-
Structured light generation by refractive-diffractive micro optical array illuminators
… source and periodic structure, where the self-imaging condition is satisfied. This phenomenon is the basis of our strategy to obtain a high-contrast far-field distribution. Throughout this thesis, we analytically, numerically, and experimentally examine the self-imaging condition for our light …
-
Adapting Without Forgetting
… and must be retrained for each new cell type or imaging condition. Foundation models offer a promising alternative through their ability to generalise across diverse domains without retraining. However, a systematic comparison of their generalisation across diverse microscopy conditions has been …
-
Um algoritmo paralelo eficiente de migração reversa no tempo (rtm) 3d com granularidade fina
… use is due to its high quality in underground imaging. The RTM is also known for its high computational cost. Therefore, parallel computing techniques have been used in their implementations. In general, parallel approaches for RTM use a coarse granularity by distributing the processing of a …
-
Theory and application of source independent full wavefield elastic converted phase seismic imaging and velocity analysis
… thus is a large source of uncertainty in seismic imaging and velocity analysis applications. In this thesis, we develop source-independent methods for seismic imaging, seismic trace interpolation and velocity analysis using the interference between pure (PP and SS) and converted-phase (PS and SP) …
-
Seismic imaging using internal multiples and overturned waves
… overturned waves and multiples in seismic imaging is one of the most plausible means by which imaging results might be improved, particularly in regions of complex subsurface structure such as salt bodies. Existing migration methods, such as Reverse Time Migration, are usually designed to …
-
Optofluidic cell stretchers using optical tweezers and interference patterns in microfluidic channels
… effective waveguide length to satisfy the self-imaging condition for optical lattice generation.</p> <p>Based on the optical lattices generated by the vertically embedded MMI polymer waveguides, we demonstrate optofluidic cell stretchers in an optofluidic chip. Leveraging the parallel stretching …
-
Well-log validated waveform inversion of reflection seismic data
… The role of the pseudo-Hessian as a gradient preconditioner is substituted with a deconvolution imaging condition. A key element of this methodology is the incorporation of log information to calibrate the update direction (i.e., a well-log validation approach), rather than determining a scalar …
-
Inverse scattering : theory and application to the imaging of the Earth's seismic discontinuities
… scattering, which enable higher resolution imaging with data from dense networks and arrays. We apply the new methods to studies of the crust beneath south Tibet and the core-mantle boundary (CMB) region beneath Central America and East Asia. First, we develop a new method, which we call …
-
Regularized wave equation migration for imaging and data reconstruction
… potential is understood using the migration imaging condition, and this encourages us to apply sparse prior models to the scattering potential. To that end, we use both a Cauchy prior and a mixed Cauchy-Gaussian prior, finding better resolved estimates of the scattering potential than are …
Page 1 of 2