  1. Assessment of imaging dose from the kilovoltage cone beam computed tomography system on board the Varian Halcyon linear accelerator

    … of the treatment plan. The frequent nature of imaging sessions mostly using kilovoltage (kV) x-ray energies has raised concerns about the contribution of low-energy radiation dose to the overall integral dose and possible induction of secondary primary tumours. In this study, the dose to organs …

    cape-town Repository record for Assessment of imaging dose from the kilovoltage cone beam computed tomography system on board the Varian Halcyon linear accelerator (opens in a new tab)

  2. Generative AI for cone-beam CT dose reduction and intensity correction in adaptive radiotherapy

    … to secondary cancer risk. However, lowering CBCT imaging dose continues to be challenging as the image quality degrades. In current practice, the frequency of scanning can be limited, leading to a potential decrease in localisation precision. Moreover, in cases of adaptation, patients are required …

    lmu-germany Repository record for Generative AI for cone-beam CT dose reduction and intensity correction in adaptive radiotherapy (opens in a new tab)

  3. Microcomputed tomography dosimetry and image quality in preclinical image-guided radiation therapy

    Motivated by the need to standardize preclinical imaging for image-guided radiation therapy (IGRT), we examine the parameters that influence microcomputed tomography (microCT) scans in the realm of image quality and absorbed dose to tissue, including therapy beam measurements of small fields. …

    uvic Repository record for Microcomputed tomography dosimetry and image quality in preclinical image-guided radiation therapy (opens in a new tab)

  4. Novel methods for iterative reconstruction and noise estimation in CT imaging

    … tomography (CT) has become an important clinical imaging modality, and has been extended into a wide range of usage with the development of novel CT scanners such as dual energy CT (DECT). However, the imaging dose during CT scanning increasingly raises public concern. Iterative reconstruction …

    gatech Repository record for Novel methods for iterative reconstruction and noise estimation in CT imaging (opens in a new tab)

  5. Low-dose imaging for particle therapy with fluence-modulated proton computed tomography

    … for the precise deposition of a therapeutic dose in the cancerous tissue while sparing surrounding healthy tissue. This exploits the increased dose deposition of charged particles, typically protons or carbon ions, at the end of their range. The treatment planning with highly conformal doses, …

    lmu-germany Repository record for Low-dose imaging for particle therapy with fluence-modulated proton computed tomography (opens in a new tab)

  6. Deep Learning-based CBCT Projection Interpolation, Reconstruction, and Post-processing for Radiation Therapy

    … computed tomography (CBCT) is an X-ray-based imaging modality widely used in medical practices. Due to the ionizing imaging dose induced by CBCT, many studies were conducted to reduce the number of projections (sparse sampling) to lower the imaging dose while maintaining good image quality and …

    duke Repository record for Deep Learning-based CBCT Projection Interpolation, Reconstruction, and Post-processing for Radiation Therapy (opens in a new tab)

  7. Low-dose ion-based transmission radiography and tomography for optimization of carbon ion-beam therapy

    … capability to precisely confine the prescribed dose within the target volume, due to the inverted depth-dose profile and the finite range featured by charged particles. However, to fully exploit the physical and biological advantages of ion-beams, it is necessary to prioritize on innovative …

    lmu-germany Repository record for Low-dose ion-based transmission radiography and tomography for optimization of carbon ion-beam therapy (opens in a new tab)

  8. FEASIBILITY OF KV SCATTERED X-RAY IMAGING FOR MARKER-FREE TUMOR TRACKING IN LUNG RADIOTHERAPY

    … photons, making kilovoltage (kV) scattered X-ray imaging a promising approach for marker-free tumor tracking in lung cancer radiotherapy. This work aims to evaluate the feasibility of kV scattered X-ray imaging for real-time tumor localization by investigating the impact of imaging geometry and …

    jhu Repository record for FEASIBILITY OF KV SCATTERED X-RAY IMAGING FOR MARKER-FREE TUMOR TRACKING IN LUNG RADIOTHERAPY (opens in a new tab)

  9. DEVELOPMENT OF A PATIENT SPECIFIC IMAGE PLANNING SYSTEM FOR RADIATION THERAPY

    … was developed that can be used to assist in kV imaging technique selection during localization for radiotherapy. The IPS algorithm performs a divergent ray-trace through a three dimensional computed tomography (CT) data set. Energy-specific attenuation through each voxel of the CT data set is …

    uky-thes Repository record for DEVELOPMENT OF A PATIENT SPECIFIC IMAGE PLANNING SYSTEM FOR RADIATION THERAPY (opens in a new tab)

  10. Imaging Techniques for Proton Range Determination in Proton Therapy

    … conversion by using protons directly as the imaging particle. A previously proved highly accurate DECT-based SPR mapping technique using a joint statistical image reconstruction method with a linear basis vector model (JSIR-BVM) was integrated with a clinical Monte Carlo-based treatment …

    wustl Repository record for Imaging Techniques for Proton Range Determination in Proton Therapy (opens in a new tab)

  11. Image quality and dose of an accelerator-integrated kV CBCT systems

    The ability of an imaging modality to precisely determine patient anatomy and provide reliable information about tumor position is critical in the radiotherapy process. As image-guided radiotherapy (IGRT) becomes more popular in radiation treatment, its overall quality and performance, such as the …

    laurentian Repository record for Image quality and dose of an accelerator-integrated kV CBCT systems (opens in a new tab)

  12. Operation, characterisation & physical modelling of unflattened medical linear accelerator beams and their application to radiotherapy treatment planning

    … radiation also causes increased whole body doses to the patient, and the filter itself causes acts as an amplifier for beam bending and steering issues. With advances in tumour imaging, dose optimisation and in-room image-guidance it is now possible to locate a tumour accurately in space and …

    birmingham Download PDF for Operation, characterisation & physical modelling of unflattened medical linear accelerator beams and their application to radiotherapy treatment planning (opens in a new tab)

  13. Towards Active Image Guidance in X-ray Fluoroscopy-guided Radiotherapeutic and Surgical Interventions

    There is growing concern regarding the ionizing dose delivered during x-ray fluoroscopy-guided minimally invasive clinical procedures, particularly in interventional cardiology and neuroradiology, and in real-time tumor tracking radiotherapy and radiosurgery. As these image-guided procedures …

    toronto-retro Repository record for Towards Active Image Guidance in X-ray Fluoroscopy-guided Radiotherapeutic and Surgical Interventions (opens in a new tab)

  14. Fluence Field Modulated Computed Tomography

    Dose management in CT is an increasingly important issue as the number of CT scans per capita continues to rise. One proposed approach for enhanced dose management is to allow the spatial pattern of x-ray fluence delivered to the patient to change dynamically as the x-ray tube rotates about the …

    toronto-retro Repository record for Fluence Field Modulated Computed Tomography (opens in a new tab)

  15. Four-Dimensional Imaging of Respiratory Motion in the Radiotherapy Treatment Room Using a Gantry Mounted Flat Panel Imaging Device

    <p>Imaging respiratory induced tumor motion in the radiation therapy treatment room could eliminate the necessity for large motion encompassing margins that result in excessive irradiation of healthy tissues. Currently available image guidance technologies are ill-suited for this task. …

    duke Repository record for Four-Dimensional Imaging of Respiratory Motion in the Radiotherapy Treatment Room Using a Gantry Mounted Flat Panel Imaging Device (opens in a new tab)

  16. MAGNETIC RESONANCE-ONLY PLANNING FOR BRAIN RADIATION THERAPY: COMPUTED TOMOGRAPHY SYNTHESIS, SEGMENTATION, AND PLAN OPTIMIZATION

    … require the acquisition of complementary imaging modalities, including computed tomography (CT) and magnetic resonance imaging (MRI), to facilitate the contouring of target volumes and surrounding organs at risk (OARs). This process is time-consuming and prone to geometric uncertainties …

    jhu Repository record for MAGNETIC RESONANCE-ONLY PLANNING FOR BRAIN RADIATION THERAPY: COMPUTED TOMOGRAPHY SYNTHESIS, SEGMENTATION, AND PLAN OPTIMIZATION (opens in a new tab) Embargoed until 2027-05-01

  17. A dosimetric study of kilovoltage cone beam CT image guidance in gynaecological radiation therapy

    … localization. However, the issue of patient dose due to repeated imaging procedures is an important topic in radiation medicine today. This thesis rigorously explores the organ equivalent doses from kilo-voltage cone beam CT to provide useful data to clinicians for decision making in image …

    ubc Repository record for A dosimetric study of kilovoltage cone beam CT image guidance in gynaecological radiation therapy (opens in a new tab) Download PDF for A dosimetric study of kilovoltage cone beam CT image guidance in gynaecological radiation therapy (opens in a new tab)

  18. Optimization of Imaging Performance and Conspicuity in Dual-Energy X-ray Radiography

    Dual-energy (DE) x-ray imaging of the chest decomposes two radiographs acquired at low- and high x-ray energies into 'soft-tissue' and 'bone' images, reducing the influence of background anatomical noise and providing increased conspicuity of subtle underlying structures compared to conventional …

    toronto-retro Repository record for Optimization of Imaging Performance and Conspicuity in Dual-Energy X-ray Radiography (opens in a new tab)

  19. Reconstruction of Volumetric Modulated Arc Therapy-Computed Tomography

    … that VMAT-CT could be a promising and convenient imaging approach for on-site treatment monitoring without introducing additional imaging dose, hardware, and cost.

    lsu-thes Repository record for Reconstruction of Volumetric Modulated Arc Therapy-Computed Tomography (opens in a new tab)