Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 94 for “"Imaging probe"”.

  1. Optomechanical design of a two-photon imaging probe

    … and time-consuming. At this point, two-photon imaging offers unique capabilities to detect cancerous tissue. To develop a two-photon imaging probe, we designed a probe that utilizes 12 collection fibers, a hollow-core excitation fiber, 4 quadrant piezoceramic tube for fiber scanning, a linear …

    texas Repository record for Optomechanical design of a two-photon imaging probe (opens in a new tab)

  2. INTERCHANGEABLE SMARTPHONE TACTILE IMAGING PROBE SYSTEM AND APPLICATIONS

    … in mechanical properties. The Smartphone Tactile Imaging Probe (STIP) is developed to quantify the mechanical properties of the tissue. The proposed system has a dual-sensing mode: compression-based sensing (STIP-C) and indentation-based sensing (STIP-I). STIP–C is designed to detect and measure …

    temple Repository record for INTERCHANGEABLE SMARTPHONE TACTILE IMAGING PROBE SYSTEM AND APPLICATIONS (opens in a new tab)

  3. Design and characterization of a hand-held, waveguide-mediated, optoacoustic imaging probe for analyzing burn wounds

    … and reduced patient outcomes. Optoacoustic imaging can provide quantitative data about burns, but the methods used present limitations that have prevented the full capability of the modality to be realized. To overcome this, our presented work used waveguide-mediated optoacoustic imaging. To …

    missouri Repository record for Design and characterization of a hand-held, waveguide-mediated, optoacoustic imaging probe for analyzing burn wounds (opens in a new tab)

  4. Endoscope presence during endoluminal functional lumen imaging probe (FLIP) influences FLIP metricsin the evaluation of esophageal dysmotility

    Background The functional lumen imaging probe (FLIP) system is an FDA-approved tool for dynamic evaluation of the esophagogastric junction (EGJ). Even though commercially available since 2009, FLIP utilization remains low, partly due to lack of consensus in methodology and interpretation. …

    zurich Repository record for Endoscope presence during endoluminal functional lumen imaging probe (FLIP) influences FLIP metricsin the evaluation of esophageal dysmotility (opens in a new tab) Restricted access

  5. Superparamagnetic iron oxide nanoparticles (SPIONs) as a multimodality imaging probe for sentinel nodes : Design and Preclinical Evaluation

    … I and II, we propose a new generation tracers (probes) based on superparamagnetic iron oxide nanoparticles (SPIONs) radiolabelled with Tc-99m and Cy 5.5 Alexa Fluor. SPIONs have the great advantage to be produced within a narrow size distribution (20-50 nm) optimal for transport via lymphatic …

    lund Repository record for Superparamagnetic iron oxide nanoparticles (SPIONs) as a multimodality imaging probe for sentinel nodes : Design and Preclinical Evaluation (opens in a new tab) Download PDF for Superparamagnetic iron oxide nanoparticles (SPIONs) as a multimodality imaging probe for sentinel nodes : Design and Preclinical Evaluation (opens in a new tab)

  6. Laboratory Application Of An Aircraft Particle Imaging Probe To Characterize Levitated Ice Crystals And Their Aerodynamic Drag

    … These ice crystals are dropped into an aircraft probe to capture a 2D image of the ice crystal profile, and a camera records the fall to extrapolate the fall time of the particle. Drag force negligibly affects the ice crystals due to the particle’s small size and the short distance to fall, with …

    nodak Repository record for Laboratory Application Of An Aircraft Particle Imaging Probe To Characterize Levitated Ice Crystals And Their Aerodynamic Drag (opens in a new tab)

  7. Optimisation studies for a high gradient proton Linac for application in proton imaging : ProBE: Proton Boosting Linac for imaging and therapy

    … Proton CT measures PSP directly and can improve imaging and treatment accuracy. The Christie Hospital will use a \SI{250}{MeV} cyclotron for proton therapy, but \SI{330}{MeV} protons are needed to image the largest adult. In this thesis the feasibility of a pulsed linac upgrade to provide …

    lancaster Download PDF for Optimisation studies for a high gradient proton Linac for application in proton imaging : ProBE: Proton Boosting Linac for imaging and therapy (opens in a new tab)

  8. SOLID PHASE SYNTHESIS OF FLUORESCENT DYE LIBRARIES AND THEIR APPLICATIONS IN BIO-IMAGING

    … have been applied to discover in vivo macrophage imaging probe (CyRCA-341) and in vitro SERS based multiplexing SERS probe (CyRLA-572) for differentiated mouse embryonic stem cells. From BDR library, (BODIPY dyes), B-cell selective probes CDg6 has been discovered and applied it separate B cell …

    nus Repository record for SOLID PHASE SYNTHESIS OF FLUORESCENT DYE LIBRARIES AND THEIR APPLICATIONS IN BIO-IMAGING (opens in a new tab) Download file for SOLID PHASE SYNTHESIS OF FLUORESCENT DYE LIBRARIES AND THEIR APPLICATIONS IN BIO-IMAGING (opens in a new tab)

  9. Preclinical and Clinical Studies of an Investigational Protease-Activated Fluorescent Probe for Cancer Theranostics

    … Here, we use a protease–activated fluorescent imaging probe, LUM015, to detect cancer in vivo in a mouse model of soft tissue sarcoma (STS) and ex vivo in a first-in-human Phase I clinical trial. In mice, intravenous injection of LUM015 labeled tumor cells and residual fluorescence detected …

    duke Repository record for Preclinical and Clinical Studies of an Investigational Protease-Activated Fluorescent Probe for Cancer Theranostics (opens in a new tab)

  10. Responsive, multimodal imaging agents for MRI: advancing the detection of metals and oxidized species implicated in neurodegenerative disorders

    … successful development of responsive, multimodal imaging agents required a bottom-up approach starting with the nature of the iron oxide nanoparticles. Thee relaxivity of the nanoparticles was found to be dependent on the total anisotropy of the particles themselves, which is in turn a function of …

    umn Repository record for Responsive, multimodal imaging agents for MRI: advancing the detection of metals and oxidized species implicated in neurodegenerative disorders (opens in a new tab)

  11. Diagnostic Imaging Approaches: Pet Imaging In Monitoring Immune Responses In Oncology And Tuberculosis

    Positron emission tomography (PET) imaging agents play a transformative role in personalized medicine through their application in disease diagnosis and immunotherapy monitoring, focusing on chemokine receptors, TH1-activated immune cells, and tuberculosis (TB) diagnostics. In immuno-oncology, …

    uab Repository record for Diagnostic Imaging Approaches: Pet Imaging In Monitoring Immune Responses In Oncology And Tuberculosis (opens in a new tab)

  12. Highly Parallel Magnetic Resonance Imaging with a Fourth Gradient Channel for Compensation of RF Phase Patterns

    … for single echo acquisition magnetic resonance imaging allows both highly accelerated imaging and capture of dynamic and single shot events otherwise inaccessible to MRI. When using RF coils with dimensions on the order of the voxel size, the array coil element phase patterns adversely affect …

    tamu Repository record for Highly Parallel Magnetic Resonance Imaging with a Fourth Gradient Channel for Compensation of RF Phase Patterns (opens in a new tab)

  13. Molecular Imaging in Noninvasive Assessment of Diabetes Progression

    Molecular imaging is a recently emerged multidisciplinary scientific field comprised of diverse technologies. The goal of this branch of science is to understand molecular mechanism of diseases and facilitate drug development, namely the interplay of non-invasive imaging techniques with molecular …

    utswmed Repository record for Molecular Imaging in Noninvasive Assessment of Diabetes Progression (opens in a new tab)

  14. HIGH-SPEED ENDOSCOPIC OPTICAL COHERENCE TOMOGRAPHY AND ITS APPLICATIONS

    … tomography (OCT) is a real-time high-resolution imaging technology providing cross-sectional images of biological structures at a resolution of <1 to 20 µm and a penetration depth of 1 to 3 mm in most highly scattering tissues. OCT is in general non-invasive and can perform real-time ‘optical …

    jhu Repository record for HIGH-SPEED ENDOSCOPIC OPTICAL COHERENCE TOMOGRAPHY AND ITS APPLICATIONS (opens in a new tab)

  15. Development of PET Imaging Probes for Predicting Response of Breast Cancer to Trastuzumab Emtansine (T-DM1)

    … do not respond. The thesis hypothesis is PET imaging that probes T-DM1 delivery to tumours and its ability to mediate HER2 downregulation would be useful in predicting the response to T-DM1 treatment. An in vivo comparison revealed that 89Zr-DFO-T-DM1 exhibited significantly higher uptake than …

    toronto-retro Repository record for Development of PET Imaging Probes for Predicting Response of Breast Cancer to Trastuzumab Emtansine (T-DM1) (opens in a new tab)

  16. Design and development of an endoscopic optical coherence tomography (OCT) imaging system

    … established as a noninvasive medical optical imaging modality that is capable of generating cross sectional images with a high axial resolution (1-10 μm) and a penetration depth of 2 mm in tissue. OCT imaging can be combined with conventional white-light endoscopes through an imaging probe …

    cork Repository record for Design and development of an endoscopic optical coherence tomography (OCT) imaging system (opens in a new tab)

  17. Imaging catalytic surfaces by multiplexed capillary electrophoresis with absorption detection

    <p>A new technique for in situ imaging and screening heterogeneous catalysts by using multiplexed capillary electrophoresis with absorption detection was developed. By bundling the inlets of a large number of capillaries, an imaging probe can be created that can be used to sample products formed …

    iastate Repository record for Imaging catalytic surfaces by multiplexed capillary electrophoresis with absorption detection (opens in a new tab)

  18. Development of Custom Imaging Arrays for Biomedical Spectral Imaging Systems

    … is at a premium. Conventional quantitative DRS imaging systems utilize unwieldy fiber probes, cooled CCD cameras, and imaging spectrographs for imaging tissue margins. These system components not only increase system size, limiting their use inside the surgical suite, but also limit imaging …

    duke Repository record for Development of Custom Imaging Arrays for Biomedical Spectral Imaging Systems (opens in a new tab)

Page 1 of 5