  1. Novel methods for magnetic resonance imaging quality assurance

    Quality control (QC) is an essential part of medical imaging workflow. Measurements assessing image validity are performed to guarantee that diagnoses are based on adequate information. Traditionally, quality assurance (QA) with imaging modalities using ionising radiation has been under strict …

    aalto Repository record for Novel methods for magnetic resonance imaging quality assurance (opens in a new tab)

  2. FROM RECUMBENCY TO STANDING: IMPROVING DIAGNOSTIC IMAGING QUALITY TROUGH THE EVOLUTION OF EQUINE ANAESTHETIC PROTOCOLS

    … last decades, both in anaesthesia and diagnostic imaging machines has lead clinicians to investigate more deeply on advantages and disadvantages of performing these examination in standing patients. General anaesthesia in this species is well known to be associated with higher risks due to body …

    milano Repository record for FROM RECUMBENCY TO STANDING: IMPROVING DIAGNOSTIC IMAGING QUALITY TROUGH THE EVOLUTION OF EQUINE ANAESTHETIC PROTOCOLS (opens in a new tab)

  3. An investigation into the use of scattered photons to improve 2D Position Emission Tomography (PET) functional imaging quality

    … tomography (PET) is a powerful metabolic imaging modality, which is designed to detect two anti-parallel 511 keV photons origniating from a positron-electron annihilation. However, it is possible that one or both of the annihilation photons undergo a Compton scattering in the object. This …

    manitoba Repository record for An investigation into the use of scattered photons to improve 2D Position Emission Tomography (PET) functional imaging quality (opens in a new tab)

  4. The development of a miniature imaging system: Design, fabrication and metrology

    … is on the development of a miniature imaging device named as multi-modal miniature microscope [a.k.a. 4M Device]. Generally speaking, the development of an optical imaging device involves three main processes: optical design, fabrication and metrology. They are interdependent and often …

    arizona-thes Repository record for The development of a miniature imaging system: Design, fabrication and metrology (opens in a new tab)

  5. Optimising Radiation Dose of CT Pulmonary Angiogram for Imaging Pulmonary Embolism and Alternative Acute Respiratory Diseases

    … embolus in various clinical settings. CT imaging has considerable advantages over other imaging modalities. Whilst considering its widespread application and advantages, it tends to have high radiation exposure. Additionally, there are high rates of suboptimal and non-diagnostic …

    anu Repository record for Optimising Radiation Dose of CT Pulmonary Angiogram for Imaging Pulmonary Embolism and Alternative Acute Respiratory Diseases (opens in a new tab)

  6. Restoration of optical coherence tomography images using stochastic methods

    … coherence tomography (OCT) is a rapidly growing imaging modality that produces high resolution three dimensional images that can be applied to different medical and industrial applications . Obtaining higher depth of imaging and higher imaging quality are important goals in OCT systems. One of …

    manitoba Repository record for Restoration of optical coherence tomography images using stochastic methods (opens in a new tab)

  7. Reflective optics-based line-scanning spectral domain optical coherence tomography system

    … a high-resolution non-invasive and non-contact imaging technology. Traditionally, multi-axis spot-focused scanning is used for transverse scanning to obtain a two or three-dimensional OCT image. This increases the time to acquire an image and imaging performance is affected by motion artifacts. …

    concordia

  8. Acoustic resolution photoacoustic microscopy imaging enhancement: learning based and model based approaches

    Photoacoustic Imaging, a novel medical imaging modality, holds great promise for non-invasive bio-tissue imaging and widespread clinical applications. Its unique combination of optical imaging contrast and acoustic imaging penetration depth delivers outstanding performance surpassing individual …

    nanyang Repository record for Acoustic resolution photoacoustic microscopy imaging enhancement: learning based and model based approaches (opens in a new tab)

  9. 2D and 3D Ultrafast Ultrasound Imaging With Coded Excitation and Aperiodic Apertures

    Ultrasound imaging is a widely used medical imaging modality for studying both static structures of the human body and dynamic processes. Currently, ultrasound images can be acquired at faster real-time imaging rates with lower quality with planewave imaging, or slower rates with higher quality …

    alberta Repository record for 2D and 3D Ultrafast Ultrasound Imaging With Coded Excitation and Aperiodic Apertures (opens in a new tab)

  10. Research on the Application of Vortex Beam in Ptychography

    … by sample size and has the advantages of high imaging quality, strong portability, and low stability requirements for optical platform. It has been experimentally confirmed in the visible light domain, X-ray and other different frequency bands. The ptychography system has a wide application …

    whiterose Repository record for Research on the Application of Vortex Beam in Ptychography (opens in a new tab)

  11. Potential usefulness and clinical relevance of a systematic implementation of transoesophageal echocardiography in the evaluation of patients with severe aortic stenosis and low gradient

    … is susceptible, to error due to suboptimal imaging quality or to morphological variations of the LVOT (i.e. sigmoid septum or sand hourglass shape) leading to an incorrect estimation of the aortic valve area (AVA) by continuity equation (CE). The purpose of this study was to evaluate the …

    fu-berlin Repository record for Potential usefulness and clinical relevance of a systematic implementation of transoesophageal echocardiography in the evaluation of patients with severe aortic stenosis and low gradient (opens in a new tab)

  12. A comparative evaluation of two Synthetic Transmit Aperture with Virtual Source beamforming methods in biomedical ultrasound

    … in biomedical ultrasound. It promises better imaging quality compared to conventional beamforming, with the same imaging speed. Several specific realizations of the STA-VS methods have been proposed in the literature and the topic is an active research area. The first part of the thesis …

    ubc Repository record for A comparative evaluation of two Synthetic Transmit Aperture with Virtual Source beamforming methods in biomedical ultrasound (opens in a new tab)

  13. Volume and Surface Integral Equations for Solving Forward and Inverse Scattering Problems

    … VSIEs. Further more, a synthetic apature radar imaging method is used in a 2D microwave imaging for complex objects. With the mono-static and bi-static interpolation scheme, a 2D FFT is applied for the imaging with the data simulated with VSIE method. Then we apply a background cancelling scheme …

    uky-thes Repository record for Volume and Surface Integral Equations for Solving Forward and Inverse Scattering Problems (opens in a new tab)

  14. GPU Enabled High Quality Ultrasound Imaging With Top Orthogonal To Bottom Electrode (TOBE) Arrays

    Ultrasound imaging is a safe, low cost, and non-invasive medical diagnostic technique. Recently 3D and 4D ultrasound methods have been highly active areas of research. Previously such datasets would be acquired with 2D matrix arrays; however, the inherent complexity in the manufacturing of such …

    alberta Repository record for GPU Enabled High Quality Ultrasound Imaging With Top Orthogonal To Bottom Electrode (TOBE) Arrays (opens in a new tab)

  15. Towards efficient portable ultrasound system: transmitter circuit design and subarray beamforming

    … integrated with the transducer providing higher imaging quality, smaller volume, and higher energy efficiency. An energy efficient level shifter for ultrasound is designed to reduce delay and power consumption of conventional level shifter designs, simulating a delay ~2.8 times lower and energy …

    nanyang Repository record for Towards efficient portable ultrasound system: transmitter circuit design and subarray beamforming (opens in a new tab)

  16. Optimal timing of pulmonary valve replacement in tetralogy of Fallot

    … patients is required. Cardiac magnetic resonance imaging is the current imaging tool of choice because it offers superior imaging quality and enables accurate quantification of functional parameters such as flow volumes and systolic and diastolic performance. Pulmonary valve replacement is often …

    leiden Repository record for Optimal timing of pulmonary valve replacement in tetralogy of Fallot (opens in a new tab)

  17. Characteristics and uses of dual-spiral dual-energy CT in radiotherapy of the head and neck

    … This research is divided in three parts: 1) imaging quality, 2) utility in tumor delineation and 3) utility in plan dose calculations. The study combines in-phantom and in-patient investigations. From the observed results, it can be concluded that Dual-Spiral Dual-Energy brings good image …

    barcelona Repository record for Characteristics and uses of dual-spiral dual-energy CT in radiotherapy of the head and neck (opens in a new tab)

  18. Innovative Modification in Reinforcement Learning Models Using Recurrent Neural Network and Autoencoder

    … the unsupervised environment and increase the imaging quality. An experiment was performed on car racing based on the designed agent model with features that could effectively be extracted to help produce reliable information. The combination of VAE and GAN provides better feature extraction to …

    ucf Repository record for Innovative Modification in Reinforcement Learning Models Using Recurrent Neural Network and Autoencoder (opens in a new tab)

  19. Optical characterization and in vivo assessment of charge-assembled capsules containing indocyanine green for laser-mediated diagnosis and therapy

    … mouse model. And the circulation kinetics and imaging quality of capsules with different coatings was assessed in mice using in vivo fluorescence imaging. Capsules containing ICG show promise for a variety of laser-mediated medical applications including phothothermal treatment of tumors and …

    rice Repository record for Optical characterization and in vivo assessment of charge-assembled capsules containing indocyanine green for laser-mediated diagnosis and therapy (opens in a new tab)

  20. Seismic reflectivity inversion using deep learning and model-based methods

    This thesis advances seismic imaging and inversion, crucial for identifying hydrocarbon prospects and understanding the Earth's internal structure by retrieving rock parameters from seismic data. Facing challenges such as solution non-uniqueness, slow convergence, and high computational demands, …

    alberta Repository record for Seismic reflectivity inversion using deep learning and model-based methods (opens in a new tab)