Immediate Loading of Unsplinted Implants in the Anterior Mandible for Overdentures
… rate and marginal bone responses around two immediately loaded unsplinted threaded implants with a fluoride-modified, micro-roughened, titanium surface in the anterior mandible retaining an overdenture, were favorable and comparable to that of conventional delayed-loaded implants.
-
Immediate Loading Of 4 Guided Implants Supporting A Maxillary Overdenture Using A Novaloc Retention System
… placed using a flapless guided approach and immediate loading with Novaloc® attachments. Subjects with fully edentulous maxillae received 4 BLX implants (Roxolid®, SLActive®, 3.75mm diameter, Institut Straumann AG, Basel, Switzerland) to support an immediately loaded overdenture. Implants …
-
Current prevalence and preferences for immediate loading of fixed completearch implant-supported prostheses: A survey among South African Prosthodontists
… is associated with high patient satisfaction. An immediate loading protocol can provide patient satisfaction in a shorter period, as the time between surgical implant placement and connection of a prosthesis is lessened. The many considerations involved in this type of treatment are either based …
-
Accuracy, Prosthetic Outcomes, and Patient-related Outcomes with Immediate Loading of 4-Guided Implants Supporting an Unsplinted Maxillary Implant-Retained Overdenture
… examine patient-related outcomes associated with immediately-loaded Mx IOD using a single-attachment abutment system. The secondary aim of the study is to examine the prosthetic complications associated with this treatment. Materials and methods: Fifteen individuals with edentulous maxillae were …
-
Evolução em carga imediata em implantes osseointegrados
… was being studied and perfected the so-called immediate loading. We know the technical and scientific advances has occurred quickly in implantology and, immediate loading in osseintegrated implants recently was completely contraindicated. With the development of morphology and the implant …
-
Outcome of Immediate Versus Delayed Loading of Full Arch Implant-Supported Fixed Prosthesis: A Systematic Review and Meta-Analysis
… the null hypothesis of no difference between immediate loading and delayed loading fixed implant-supported restoration for completely edentulous arch in terms of implant failure rates and marginal bone resorption against the alternative hypothesis of a difference. Materials and methods: An …
-
Clinical Trials and Treatment Outcomes of Edentulous PatientsTreated with Implant-supported Prosthesis
… it was shown that long-term results following immediate loading of endosseous implants with overdentures were successful based on biological and clinical parameters, cost to patient, and patient-based outcomes. Moreover, it was noted that well-designed clinical trials evaluating efficacy of …
-
Immediate Versus Delayed Loading of Two Unsplinted Implants Supporting a Locator™ Retained Mandibular Overdenture. A Randomized Controlled Study
… of edentulous mandibles. In addition, the use of immediate loading may reduce the treatment time and improve the patient comfort without jeopardizing implant success. Limited information is available on the clinical success of immediate loading of 2 unsplinted implants supporting a mandibular OVD. …
-
Clinical outcomes of the Nobel Active dental implant system after one year of loading : a retrospective multicentre analysis
… around Nobel Active implants after one year of loading. Methods: The study included 124 NobelActive dental implants that were placed by experienced practitioners in two private clinics and by senior Graduate Periodontics residents at the University of British Columbia. The effect of patient, …
-
On various protocols for direct loading of implant-supported fixed prostheses
… a healing period of 3 to 6 months prior to loading which means that the total treatment time can be extensive and that the patients often need to wear removable provisional prostheses during healing and treatment. The use of immediate implant loading protocols would significantly reduce …
-
Carga Imediata oclusal vs Carga Imediata no sector posterior
… dentistry there are several clinical studies on immediate loading. However, this topic is still shrouded in some controversy, also occurring in the subjective interpretation on the role of articulation paper in obtaining contacts in many of these studies. To date there are no known published …
-
Avaliação dos Micromovimentos e Deformações Superficiais de Implantes Sujeitos a Carga Imediata: Estudo Ex Vivo
… This study aims to evaluate the influence of immediate loading on the primary stability and micromovements (MM) of dental implants with different diameters and macrogeometries. To this end, the effects of loading cycles on implants placed in bovine ribs were investigated using Digital Image …
-
Implant-Supported Prosthesis in Fibula Free Flap Jaw-in-a-Day Reconstruction Using Finite Element Analysis
… 2013 further transformed treatment by enabling immediate implant-supported prosthetic loading through digital virtual surgical planning. However, two biomechanical controversies remain unresolved: optimal fibula positioning (superior vs. inferior) and prosthetic loading protocol (immediate vs. …
-
Immediate Versus Delayed Loading of Two Implants Supporting A Locator Retained Mandibular Overdenture. A Randomized Controlled Study.
The aim of this study was to evaluate immediate versus delayed loading of two implants, six months post-surgery, supporting a locator retained mandibular overdenture. The objective was to evaluate implant bone remodelling using radiographic bone level changes (RBL) as the variable, from baseline to …
-
Comparison between immediate and conventional implant loading for fixed and removable prosthesis
Literature states that different loading systems have been explored; and are used depending on the clinical situation. The success with each of these systems also differs with regards to quality of bone, the length and diameter of an implant, whether the implant is placed anteriorly or posteriorly, …
-
Survival and success of dental implants using screw-retained fixed rehabilitation of the edentulous mandibular dental arch
… supported fixed prostheses was not affected by immediate loading of the prostheses. 5. Immediate loading of the prostheses did not affect the success and survival of implant and implant supported fixed prostheses. CONCLUSION: New criteria that are widely accepted, reproducible, and easy to …
-
Effect of Temporal Onset of Mechanical Loading on Tendon to Bone Healing, Determined with a Novel In-Vivo Device
Background: Exposure to tensile loading has been shown to maintain tendon/ligament homeostasis, with the tensile modulus of the tissue increasing in response to greater loading frequency, and even decreasing in the absence of load. However after injury or surgical repair the effect of tensile load …
-
Performance mastigatória e impacto da saúde oral na qualidade de vida em pacientes reabilitados com prótese fixa implantossuportada com carga imediata
… patients with CCD and ISD under lower immediate loading. The sample consisted of 40 individuals, mean age of 59.08 years (± 7.04), predominantly female (n = 36), were divided into two groups: CCD and ISD. All patients were rehabilitated with CCD initially, 23 remained with their CCD, …
-
PROTESI PARZIALE FISSA, IMPLANTO-SUPPORTATA A CARICO IMMEDIATO: STUDIO PROSPETTICO
The aim of the study is to analyze immediate loading in FPD. 8 patients were rehabilitated with 20 implants (Straumann RN TL 4.1x10mm) and immediate FPD. 9 patients were rehabilitated with 20 implants (Straumann RN TL 4.1x10mm) and early loading protocol. We analyze bone density according to …
-
CLINICAL AND RADIOGRAPHIC EVALUATION OF MARGINAL BONE RESORPTION OF ONE-PIECE IMPLANTS IN FULL ARCH REHABILITATIONS WITH FULL DIGITAL APPROACH: A PROSPECTIVE COHORT STUDY.
… performance of monophasic implants subjected to immediate loading. These implants, characterized by the elimination of the abutment-fixture interface, aim to enhance mechanical stability and minimize the risks of peri-implant diseases, thus optimizing aesthetic and functional outcomes. The study …