Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 20 of 20 for “"Impedance Measurement System"”
-
High performance wireless bio-impedance measurement system
Electrical and Computer Engineering
-
Development on Impedance Measurement System For Electrochemical Impedance Spectroscopy
Electrochemical impedance spectroscopy (EIS) has been used in various applications, such as metal corrosion monitoring. However, many conventional corrosion monitoring setups are bulky and inconvenient for in-situ testing. Reducing the size of the whole corrosion monitoring system is one of the …
-
Development of a bio-impedance measurement system for bladder monitoring
… this purpose, the development of a low cost bio-impedance measurement system as a method for bladder monitoring is investigated in this thesis. Prior to this thesis, the trend in the literature was to identify the correlation between the change of the impedance and the accumulation of urine in …
-
Impedance measurement system for embryonic stem cell and embryoid body cultures
… an experimental setup to assess the ability of impedance measurements to characterize mouse embryonic stem cell (ESC) and embryoid body (EB) growth and differentiation. Existing quality assurance measurements used to stage the growth and differentiation of embryoid bodies are labor intensive and …
-
Application specific DAC and ADC for a bio-impedance measurement circuit
… The circuits are intended to be a part of a bio-impedance measurement system in which a current is injected into the myocardium tissue and blood pool for the purpose of determining the heart’s stroke volume. The DHC DAC injects a 100 μA[subscript rms] current at a 20 kHz fundamental frequency …
-
Nanomaterial-Enhanced Multiplexed High Throughput Point-Of-Care Electronic Biosensing Of Antibody Biomarkers Of Neglected Tropical Diseases
… The electronic platform needed an automated impedance measurement system, so I built the Zscan to minimize measurement error and increase the overall speed and repeatability of the process. Following this, I’ve applied the POC platforms to two NTDs; Onchocerciasis and Schistosomiasis. …
-
Hardware development of non-contact online impedance analyzer
… the development of a non-contact, real-time impedance measurement system that addresses the limitations of traditional sinusoidal signal-based methods by introducing multi-harmonic signals such as square and triangular waves at a test frequency of 100 kHz. The proposed methodology combines …
-
Design of an Embedded System for Fast Classification of Bimetallic Coins by Impedance Spectroscopy
A novel embedded impedance measurement system for counterfeit detection of bimetallic coins is presented. The system integrates Eddy current sensors with inductive spectroscopy, facilitating the detection of hidden inlay security features and the identification of surface minting. A salient feature …
-
A low-cost, portable, web-based impedance spectroscope for agricultural applications
Electrical impedance spectroscopy (EIS) is an electrochemical characterization technique widely exploited in the field of chemistry, material science, and biology. EIS characterizes the dynamics of fixed and mobile charge carriers at the electrode-sample interface. It has proved useful in the …
-
Nondestructive Residual Stress Assessment of Shot-Peened IN718 Using Hall Coefficient Spectroscopy
… of high-frequency eddy current conductivity measurements for residual stress assessment of shot-peened aerospace superalloys. In precipitate hardened IN718, specifically, it was revealed that the influence of cold work and compressive residual stress on the electrical conductivity cancel each …
-
Design and Implementation of a Magnitude Only Bio-Impedance Analyzer
The increasing interest in the bio-impedance analysis in various fields has increased the demand for portable and low-cost impedance analyzers that can be used in the field. Simplifying the hardware is crucial to maintaining low-cost and portability, but this is not an easy task due to the need for …
-
Inductively coupled in-circuit impedance measurement based on two-port network characterization
In-circuit impedance information is one of the parameters for condition monitoring of an electrical system. Besides condition monitoring, it also provides impedance information of a switching converter connected to high voltage power supply so that an optimal electromagnetic interference (EMI) …
-
A method for the assessment of EMI suppression performance of ferrite core loaded power cord
… most research work has been focused on the impedance characteristics of a ferrite core and its loading effects on various types of the transmission lines. However, most of these measurement setups are still designed based on 50 0 test system. Unfortunately, the source and load impedances of …
-
Novel Magnetic Materials for Sensing and Cooling Applications
… PhD research are to explore the giant magnetoimpedance (GMI) and giant magnetocaloric (GMC) effects in functional magnetic materials and provide guidance on the optimization of the material properties for use in advanced magnetic sensor and refrigeration applications. GMI has attracted growing …
-
CT On A Chip: Enabling High-Resolution Polar In-Situ Data Collection
… the globe through the thermohaline circulatory system via the Antarctic Bottom and Intermediate Waters. Melting plays a major role in generating this cold, fresh water, but melt rates are difficult to measure under hundreds of meters of ice, and different parameterizations of this critical …
-
Detection of Cancer-related Biomarkers utilizing Electrical Impedance Sensors
… focuses on the development of electrical impedance sensors to detect different types of cancer-related biomarkers: microRNA, genomic mtDNA and exosomes. First, we report a new nanopore-based detection scheme utilizing a borosilicate micropipette and an assay of complementary r-peptide …
-
Mixed-Signal IC design for Heterogeneously Integrated Multi-Analyte Chemical Sensor Arrays
… that demonstrate a variation of resistance (or impedance) in the presence of chemical agents. For this thesis, the sensor can be either a chemoresistive bead or a nanowire. By integrating multiple non-specific chemoresistive sensors together in arrays, a cross-reactive array can be realized, …
-
Medium Voltage Impedance and Admittance Measurement and System Identification Techniques
… of renewable energy sources in modern power systems, as well as the integration of power electronics equipment, is shaping the requirements for stable grid infrastructure. These requirements mainly come from the stability-related phenomena arising from different subsystem interactions. …