Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 1769 for “"Impedance Spectroscopy"”.
-
Integrated impedance spectroscopy biosensors
… modalities for biosensors, Electrochemical Impedance Spectroscopy (EIS) permits real-time detection and has label-free detection capabilities. EIS is fully electronic in nature. Hence, it can be implemented using standard IC technologies. The versatility and ease of integration of EIS makes …
-
Single-Cell Impedance Spectroscopy
Impedance spectroscopy (IS) is an important tool for cell detection and characterization in medical and food safety applications. In this thesis, the Cal Poly Biofluidics Lab’s impedance spectroscopy system was re-evaluated and optimized for single-cell impedance spectroscopy. To evaluate the IS …
-
Microfluidic Electrical Impedance Spectroscopy
… device capable of measuring changes in impedance valuesof microfluidic cell cultures. Tocharacterize this, an interdigitated array of electrodes was patterned over glass, where it was then bonded to a series of fluidic networks created in PDMS via soft lithography. The device measured …
-
IMPEDANCE SPECTROSCOPY OF SILICON SOLAR CELLS
In this thesis, impedance spectroscopy was performed on both large-area and small-area silicon solar cells to characterize the impedance of the solar cells. Impedance spectroscopy using silicon cells is relatively novel, and the new contribution to knowledge here was that emitter saturation current …
-
Single-cell impedance spectroscopy of bacteria
… bacteria were measured using single-cell impedance cytometry in order to understand changes in electrical properties following exposure to different perturbations. Traditionally, alternating current (AC) electrokinetic methods are used to measure the electrical properties of cells. …
-
A Microfluidic Device for Impedance Spectroscopy
… to build novel biomedical devices. Dielectric spectroscopy, on the other hand, allows non-invasive probing of biological cells. Information on the cell membrane, cytoplasm, and nucleus can be obtained by dielectric spectroscopy provided that appropriate tools are used in specific frequency …
-
Low frequency sinusoidal oscillator for impedance spectroscopy
Impedance measurement as a function of frequency is being increasingly used for the detection of organic molecules. The main building block required for this is a sinusoidal oscillator whose frequency can be varied in the range of a few KHz to tens of MHz. The thesis describes the design of …
-
Investigating Inductive Loops in Electrochemical Impedance Spectroscopy
… low frequency range of the Nyquist plot of the impedance function. This has puzzled scientists for decades because the electrochemical impedance is known to have a purely negative imaginary part. In this dissertation we will show that the lack of time-invariance can be a source of inductive …
-
Impedance spectroscopy for cellular and biomolecular analysis
… known as ‘Lab On a Chip’ devices.<br/>Impedance spectroscopy is a non-invasive, label-free, analytical technique that is amenable to miniaturization, electronic integration, automation, and scalability within ‘LOC’ devices.<br/>This thesis describes a microfabricated device for …
-
Impedance Spectroscopy to Measure Placental Barrier Integrity
… technique allowing such monitoring is called bioimpedance spectroscopy to measure the transepithelial/transendothelial electrical resistance (TEER) and the electrical capacitance of cell membrane. The aim of this thesis is to (i) Design and optimize a low cost, effective and reproducible …
-
Characterisation of Water Infrastructure using Impedance Spectroscopy
… Secondly, a sensing system based on electrical impedance spectroscopy (EIS) has been developed as a method for characterising the grain size, porosity and hydraulic permeability of various sizes of glass beads and mixtures composed of sand or glass beads. The EIS involves applying an AC …
-
Detection of chronic wound infection using impedance spectroscopy
… study explores the detection of infections using impedance spectroscopy to monitor bacteria.Initial electrochemical impedance spectroscopy experiments using label-less carbon screen printed electrodes were conducted to characterise the impedance signatures of Staphylococcus aureus, Pseudomonas …
-
Impedance spectroscopy response of aluminum-copper-silicon alloys
… Al-Cu-Si alloys was evaluated. Electrochemical impedance spectroscopy and DC polarization techniques were combined with mechanical property evaluations to determine the relationship between the microstructure of Al-Cu-Si alloys and the ability of their oxide layer to provide protection against …
-
Study of Ion Exchange Media with Impedance Spectroscopy
… in a water softener or via a remote sensor using impedance measurement techniques. In this study, a frequency of approximately 10 kHz was selected to measure the impedance of the ion exchange bed throughout the regeneration and depletion cycle. Impedance spectroscopy has been used to characterize …
-
Electrical characterization of phytoplankton suspensions using impedance spectroscopy.
… suspended in a stagnant medium and measured the impedance response using a lab-on-chip and impedance analyzer. The individual cell characteristics were derived from the impedance response of the group. The goal was to characterize and differentiate between algae species, as well as healthy and …
-
Microfluidic Electrical Impedance Spectroscopy System Automation and Characterization
… culture platform capable of automated electrical impedance measurements and immunofluorescence and brightfield microscopy was developed for further in-vitro cellular research intended to optimize cell culture conditions. The microfluidic system design, fabrication, automation, and design …
-
A compact fully on-chip impedance spectroscopy system
Thesis (M.S.)--Michigan State University. Department of Electrical Engineering, 2007
Page 1 of 89