Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 68 for “"Impedance cardiography"”

  1. Impedance cardiography

    O desenvolvimento de técnicas de diagnóstico para deteção prematura de fatores de risco cardiovascular permite o tratamento antecipado das doenças cardíacas, aumentando a probabilidade de sobrevivência. A monitorização do débito cardíaco com base em métodos invasivos tem sido um padrão para …

    coimbro Repository record for Impedance cardiography (opens in a new tab)

  2. Impedance cardiography in the elderly

    Experience gained by performing 1250 impedance cardiograms in 362 elderly subjects has shown that the technique is simple, noninvasive and highly reproducible; it lends itself to the investigation of cardiovascular problems in the elderly. Minor modifications to the method, as applied to the …

    glasgow Repository record for Impedance cardiography in the elderly (opens in a new tab)

  3. An Evaluation of Ensemble Average As Applied to Impedance Cardiography

    Impedance cardiographic data measurements made by a standard hand-digitizing method were compared with those made by a new ensemble averaging technique. Five healthy, young males were monitored in the supine and seated positions during rest and two stages of bicycle exercise. We found ensemble …

    marquette Repository record for An Evaluation of Ensemble Average As Applied to Impedance Cardiography (opens in a new tab)

  4. Evaluation of impedance cardiography (ICG) for assessing hemodynamic parameters in Fontan patients

    Introduction: Hemodynamic assessment using currently available methods is particularly challenging in the Fontan population. Patients with Fontan circulation are generally described to have chronically low cardiac output (CO) and high central venous pressure (CVP). Reduced exercise capacity is …

    manitoba Repository record for Evaluation of impedance cardiography (ICG) for assessing hemodynamic parameters in Fontan patients (opens in a new tab)

  5. Using impedance cardiography to examine changes in hemodynamic parameters during heart rate biofeedback

    … arithmetic challenge, as HR, blood pressure, and impedance cardiography-derived measures were recorded. During the training sessions, the FB+ group received HR feedback and the FB-- group was not provided with HR feedback while playing the videogame. Results revealed that those in de FB+ group …

    wvu Repository record for Using impedance cardiography to examine changes in hemodynamic parameters during heart rate biofeedback (opens in a new tab)

  6. Accuracy of impedance cardiography for the measurement of stroke volume and hemodynamic factors affecting this method

    This document only includes an excerpt of the corresponding thesis or dissertation. To request a digital scan of the full text, please contact the Ruth Lilly Medical Library's Interlibrary Loan Department (rlmlill@iu.edu).

    iupui Repository record for Accuracy of impedance cardiography for the measurement of stroke volume and hemodynamic factors affecting this method (opens in a new tab)

  7. Analysis of defibrillation efficacy and investigation of impedance cardiography with finite element models incorporating anisotropic myocardium

    … and spot-electrode location affects the measured impedance change in impedance cardiography using realistic diastolic and systolic human thorax models. The results show that ventricular contraction, the only factor that increases systolic impedance, has a larger effect than the resulting expansion …

    washington Repository record for Analysis of defibrillation efficacy and investigation of impedance cardiography with finite element models incorporating anisotropic myocardium (opens in a new tab)

  8. The contribution of exercise haemodynamic measurements by signal-morphology impedance cardiography in the management of cardiac rehabilitation patients

    La Réadaptation Cardiaque (RC) constitue l’un des piliers de la prévention secondaire, mais son intégration technologique et méthodologique demeure inégale selon les pays et les structures de soins. Dans ce contexte d’hétérogénéité, l’absence fréquente de suivi hémodynamique avancé limite la …

    star-france Repository record for The contribution of exercise haemodynamic measurements by signal-morphology impedance cardiography in the management of cardiac rehabilitation patients (opens in a new tab)

  9. Συσχέτιση ολικών περιφερικών αντιστάσεων με την λειτουργία της αριστερής κοιλίας σε ασθενείς με χρόνια νεφρική ανεπάρκεια και θεραπείες υποκατάστασης

    … others. All patients underwent a complete echocardiography study for determining left ventricular structural and functional status according to ASE guidelines. Systemic vascular resistance was studied by various methods although it was mainly registered by means of ultrasonography (aortic pulse …

    greece Repository record for Συσχέτιση ολικών περιφερικών αντιστάσεων με την λειτουργία της αριστερής κοιλίας σε ασθενείς με χρόνια νεφρική ανεπάρκεια και θεραπείες υποκατάστασης (opens in a new tab)

  10. Advanced bioimpedance signal processing techniques for hemodynamic monitoring during anesthesia

    … recovery time, and improved patient outcome. Impedance Cardiography (ICG) is a promising noninvasive technology for cardiac output monitoring but available information on the ICG signals is more scare than other physiological signals such as the electrocardiogram (ECG). The present Doctoral …

    barcelona Repository record for Advanced bioimpedance signal processing techniques for hemodynamic monitoring during anesthesia (opens in a new tab)

  11. The Development, Evaluation and Validation of a Novel Measure of Financial Stress

    … reactivity to laboratory stressors using impedance cardiography. Results suggest that the scale does have predictive validity for some cardiovascular reactivity variables. Possible implications for health are discussed.

    ohiolink Repository record for The Development, Evaluation and Validation of a Novel Measure of Financial Stress (opens in a new tab)

  12. Device, Method, and Algorithm to Assess Changes in Cardiac Output via Intracardiac Impedance Monitoring

    … medical device. The principles of traditional impedance cardiography, an established cardiac output monitoring technique in practice for over fifty years, have been adapted to incorporate a leadless artificial cardiac pacemaker, an implantable medical device contained entirely within the heart. …

    portland-state Repository record for Device, Method, and Algorithm to Assess Changes in Cardiac Output via Intracardiac Impedance Monitoring (opens in a new tab)

  13. Resiliency and Autonomic Control of Cardiac Responses to Stress

    … activation along a continuum of threat. Electrocardiography and impedance cardiography were collected before, during, and after these tasks to assess changes in autonomic functioning. Results from multiple regression analyses indicated that high levels of EC predicted increased vagal control …

    vt Repository record for Resiliency and Autonomic Control of Cardiac Responses to Stress (opens in a new tab)

  14. Μελέτη των αλλοιώσεων μικρών και μεγάλων αγγείων σε ασθενείς με ρευματοειδή αρθρίτιδα

    … 24hour ambulatory blood pressure measurement and impedance cardiography were applied. 10-year risk of general cardiovascular disease was estimated from the Framingham Heart Study. Galectin-3 levels were measured in serum samples with ELISA.Patients with RA, compared to controls, presented …

    greece Repository record for Μελέτη των αλλοιώσεων μικρών και μεγάλων αγγείων σε ασθενείς με ρευματοειδή αρθρίτιδα (opens in a new tab)

Page 1 of 4