Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 27 for “"Impedance monitoring"”

  1. Non-invasive impedance monitoring of vascular cell growth on coronary stents

    … unclear and there are no means of non-invasively monitoring this process in vivo.Existing real time monitoring of impedance in cell cultures provides information related to cell activity, adherence and confluence. Therefore, collection of such information applied to coronary stents may be a first …

    strathclyde Repository record for Non-invasive impedance monitoring of vascular cell growth on coronary stents (opens in a new tab)

  2. Device, Method, and Algorithm to Assess Changes in Cardiac Output via Intracardiac Impedance Monitoring

    … dysfunction and often require long-term cardiac monitoring support. This thesis proposes a novel cardiac output monitoring solution which leverages an implantable intracardiac medical device. The principles of traditional impedance cardiography, an established cardiac output monitoring technique …

    portland-state Repository record for Device, Method, and Algorithm to Assess Changes in Cardiac Output via Intracardiac Impedance Monitoring (opens in a new tab)

  3. AC Electrical Impedance Monitoring and Modeling of Crop Growth and Development "Tomato Fruit Ripening"

    … to study the suitability of using AC electrical impedance measurements to monitor and model the growth and development of a crop, the tomato, while "on the vine." The use of impedance measurements is an indirect technique in which the measurements are correlated with known states of the specimen. …

    marquette Repository record for AC Electrical Impedance Monitoring and Modeling of Crop Growth and Development "Tomato Fruit Ripening" (opens in a new tab)

  4. Evaluation of acid suppression medications, symptoms and type of feeding in infants suspected of gastroesophageal reflux utilizing pH-impedance monitoring

    … Combined pH-multichannel intraluminal impedance (pH-MII) studies were retrospectively reviewed in 186 infants. We evaluated GER characteristics to compare those infants on ranitidine, lansoprazole and no medications; investigated if the method of feeding (oral, nasogastric or …

    ohiolink Repository record for Evaluation of acid suppression medications, symptoms and type of feeding in infants suspected of gastroesophageal reflux utilizing pH-impedance monitoring (opens in a new tab)

  5. Orientation-dependent adaptive antenna for low earth orbit satellite communications

    … uses a back-to-back patch antenna design with an impedance monitoring based system capable of adaptively controlling the pattern of the antenna. The adaptive antenna system was designed, simulated, fabricated, and measured. The system could detect a head phantom within 3 cm of the antenna. SAR …

    manitoba Repository record for Orientation-dependent adaptive antenna for low earth orbit satellite communications (opens in a new tab)

  6. Gastric and small intestinal motor function in health and disease - implications for glucose absorption, incretin hormone release, and postprandial blood glucose regulation.

    … More recently, using a combined manometry and impedance monitoring technique, it has been demonstrated that duodenal flow events may be a more important determinant of glucose absorption than pressure waves. Impedance monitoring is capable of measuring intraluminal movement of both fluid and …

    adelaide Repository record for Gastric and small intestinal motor function in health and disease - implications for glucose absorption, incretin hormone release, and postprandial blood glucose regulation. (opens in a new tab)

  7. ANALYSIS AND IMPEDANCE-BASED DETECTION OF ELECTROMAGNETIC COIL INSULATION DEGRADATION

    … reliability. An effective insulation health monitoring program can reduce maintenance and replacement costs, predict the useful lifetime of the coil, and improve the operational availability of the system in which the coil is used. Impedance monitoring of coils has emerged as a promising …

    maryland Repository record for ANALYSIS AND IMPEDANCE-BASED DETECTION OF ELECTROMAGNETIC COIL INSULATION DEGRADATION (opens in a new tab)

  8. Understanding and monitoring the dynamic process of bipolar tissue hemostasis process

    … ultimate goal of this study is to develop online monitoring methods to improve the quality of the bipolar tissue hemostasis process. A systematic study was conducted to gain better understanding on how process variables, such as compression level, heating power, and heating duration, would impact …

    texas Repository record for Understanding and monitoring the dynamic process of bipolar tissue hemostasis process (opens in a new tab)

  9. Surface and electrochemical properties of anodized pure iron for bioresorbable stents

    … charge transfer resistance during time-dependent impedance monitoring. In vitro assays using extracts demonstrated that anodized samples supported endothelial cell proliferation for up to 5 days. Overall, anodized nanotubular oxide layers enable effective control of surface properties, degradation …

    metu Repository record for Surface and electrochemical properties of anodized pure iron for bioresorbable stents (opens in a new tab)

  10. Apnea e reflusso gastroesofageo nel neonato pretermine

    … synchronized recording of polysomnography and pH-impedance monitoring (pH-MII). Polysomnography detects and characterizes apneas, by recording of breathing movement, nasal airflow, electrocardiogram, pulse oximeter saturation. pH-MII is the state-of-theart methodology for GER detection in preterm …

    bologna Repository record for Apnea e reflusso gastroesofageo nel neonato pretermine (opens in a new tab)

  11. Effect of Pre-anesthestic Fasting Time on Gastroesophageal Reflux and Stomach Size

    … and GER events were recorded using esophageal pH/impedance monitoring and endoscopic visualization of reflux. Recording for a GER event was performed for one hour. No premedication was utilized during the study. A wash out period of 14 days occurred between anesthetic episodes and all dogs rotated …

    okstate Repository record for Effect of Pre-anesthestic Fasting Time on Gastroesophageal Reflux and Stomach Size (opens in a new tab)

  12. Characterization of advanced etching reactors using novel diagnostic tools

    … been found to be useful for in situ real-time monitoring of end-point and uniformity of etching as well as for inferring wafer temperature and heat transfer characteristics. Also, a simple end-point detection technique based on plasma impedance monitoring was developed which eliminates the need …

    njit Repository record for Characterization of advanced etching reactors using novel diagnostic tools (opens in a new tab)

  13. Evaluating Corrosion Behaviour of Copper Under Deliquescent Drying/Wetting Cycles in Humid Air Condition

    … of chloride salts and advances techniques for monitoring and characterizing corrosion processes relevant to atmospheric corrosion. Quartz crystal microbalance with acoustic impedance monitoring (QCM-I) was evaluated for its ability to simultaneously monitor corrosion and the changing …

    uwo Repository record for Evaluating Corrosion Behaviour of Copper Under Deliquescent Drying/Wetting Cycles in Humid Air Condition (opens in a new tab)

  14. Characterization of cell-matrix interactions during multipotent mesenchymal stromal cell (MSC) differentiation

    … under varying conditions employing non-invasive impedance monitoring in real-time, using fibroblast and keratinocytes as non-specific controls. Major focus was on changes in adhesion and migration of MSCs induced to differentiate into adipogenic and osteogenic lineages, the effects of …

    heid-diss Repository record for Characterization of cell-matrix interactions during multipotent mesenchymal stromal cell (MSC) differentiation (opens in a new tab)

  15. Exploring Gastro-oesophageal Reflux in Infants and Children

    … II). This technique has now evolved to include impedance, and based on this evidence, I set up a pH/impedance monitoring service in Poole for paediatric patients. I then appraised the evidence-base using Cochrane methodology given the improved robustness of evidence given by well-designed …

    bournemouth Repository record for Exploring Gastro-oesophageal Reflux in Infants and Children (opens in a new tab)

  16. Applications Of Impedance Identification To Electric Ship System Control And Power Hardware-In-The-Loop Simulation

    … for converter interactions and allows for impedance based control is proposed. The use of impedance monitoring via wideband impedance identification techniques provides interesting opportunities for the development of a robust and adaptive control strategy. Power converters within the …

    south-carolina Repository record for Applications Of Impedance Identification To Electric Ship System Control And Power Hardware-In-The-Loop Simulation (opens in a new tab)

  17. Validazione e applicazioni cliniche della metodica NIRA (Near Infrared Reflectance Analysis) per la valutazione del contenuto nutrizionale del latte materno in terapia intensiva neonatale

    … and fortified HM by combined pH/intraluminal-impedance monitoring (pH-MII). HM fat and protein content was analysed by a Near-Infrared-Reflectance-Analysis (NIRA). HM osmolality was tested before and after fortification. GER indexes measured before and after fortification were compared, and …

    bologna Repository record for Validazione e applicazioni cliniche della metodica NIRA (Near Infrared Reflectance Analysis) per la valutazione del contenuto nutrizionale del latte materno in terapia intensiva neonatale (opens in a new tab)

  18. INTER-OBSERVER AND INTRA-OBSERVER AGREEMENT IN THE ANALYSIS OF OESOPHAGEAL PH-IMPEDANCE TRACINGS.

    AIM Information resulting from oesophageal 24h pH-impedance monitoring (pH-MII) may have important consequences for patients’ management. Aims of this study were 1) to evaluate agreement for number of reflux episodes and symptom/reflux association indexes in MII-pH tracings analysis between and …

    milano Repository record for INTER-OBSERVER AND INTRA-OBSERVER AGREEMENT IN THE ANALYSIS OF OESOPHAGEAL PH-IMPEDANCE TRACINGS. (opens in a new tab)

  19. RELEASE FROM BIODEGRADABLE BIO-HYBRID HYDROGEL AND ELECTROSTIMULATION: TOWARD A BIOMIMETIC ENVIRONMENT FOR ENDOTHELIAL CELLS

    … (ECSARA) equipped with in-situ electrical impedance spectroscopy (EIS) for real-time, non-invasive monitoring was developed to apply endogenous-range electric fields (EF) to cells in 3-D culture. The 24-well electroculture ware with trans-well Ti electrodes produced a uniform EF …

    tamu Repository record for RELEASE FROM BIODEGRADABLE BIO-HYBRID HYDROGEL AND ELECTROSTIMULATION: TOWARD A BIOMIMETIC ENVIRONMENT FOR ENDOTHELIAL CELLS (opens in a new tab)

Page 1 of 2