Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 259 for “"Impedance-Based"”

  1. Heterogeneously Integrated Impedance Based Biosensors

    … electrodes, was applied to measure the impedance of suspended DNA at different concentrations. The measurement showed a double sensitivity compared to the one carried out on the CMOS platform only. The noise analysis of CMOS transimpedance amplifiers was performed, and the impact of …

    cambridge Repository record for Heterogeneously Integrated Impedance Based Biosensors (opens in a new tab)

  2. Impedance-based battery temperature monitoring

    … is important for safety and control purposes. Impedance temperature detection (ITD) is a promising approach for temperature estimation, whereby the internal cell temperature is directly inferred from online electrochemical impedance spectroscopy (EIS) measurements at a single frequency. …

    oxford Repository record for Impedance-based battery temperature monitoring (opens in a new tab)

  3. Implementing Impedance - Based Health Monitoring

    This work is an experimental study of applying an impedance-based health monitoring technique to complex structures. The work is presented in three parts. In the first part we consider effects of the following three factors on damage detection abilities: actuator excitation level, test wire length …

    vt Repository record for Implementing Impedance - Based Health Monitoring (opens in a new tab)

  4. Development of impedance-based sensing systems

    This work demonstrates how impedance-based sensors can be transformed into adaptable biomedical tools, emphasizing the need to rethink how emerging technologies are integrated into healthcare systems. The future of diagnostics is moving away from centralized laboratory settings toward …

    qucosa-diss Repository record for Development of impedance-based sensing systems (opens in a new tab)

  5. An impedance based single cell deformability cytometer

    … hydrodynamic induced stress by measuring their impedance along different axes using microelectrodes placed on the top and the bottom of a microchannel. The device can distinguish cells treated with glutaraldehyde, which makes their membrane stiffer. The ratio of the parameter defined as …

    soton Repository record for An impedance based single cell deformability cytometer (opens in a new tab)

  6. Impedance-based Nondestructive Evaluation for Additive Manufacturing

    Impedance-based Non-Destructive Evaluation for Additive Manufacturing (INDEAM) is rooted in the field of Structural Health Monitoring (SHM). INDEAM generalizes the structure-to-itself comparisons characteristic of the SHM process through introduction of inter-part comparisons: instead of comparing …

    vt Repository record for Impedance-based Nondestructive Evaluation for Additive Manufacturing (opens in a new tab)

  7. Sensitivity analysis of impedance-based fault location methods

    Impedance-based methods are used to locate faults on distribution systems because of their simplicity and ease of implementation. These methods require fault voltage and current data along with the positive- and zero-sequence line impedance values (in ohm per unit length) to estimate the reactance …

    texas Repository record for Sensitivity analysis of impedance-based fault location methods (opens in a new tab)

  8. An impedance based method for distribution system monitoring

    … and control system, in distribution network, are based on the radial distribution systems assumption. The high penetration of the renewable energy sources, will clearly impact the distribution systems operation. Unlike other ways of electricity generation renewable energies initiate some …

    ets-quebec

  9. Impedance-Based Structural Health Monitoring to Detect Corrosion

    … In this first third of this study, the impedance method was experimentally tested to detect and the onset and growth of the earliest stages of pre-crack surface corrosion in beam and plate like structures. Experimental results indicate the impedance method is an effective detection tool …

    vt Repository record for Impedance-Based Structural Health Monitoring to Detect Corrosion (opens in a new tab)

  10. Impedance-Based Water-Quality Monitoring Using Parallel Plate Method

    The application of electromagnetic (EM) waves to measure the electrical properties (dielectric constant and loss tangent) of materials is a well-known approach. The electrical properties can be used to indirectly measure several physical properties of solutions in water such as the concentration …

    boise Repository record for Impedance-Based Water-Quality Monitoring Using Parallel Plate Method (opens in a new tab)

  11. Impedance-Based Structural Health Monitoring of Wind Turbine Blades

    … life and allow for less conservative designs. Impedance-based SHM is a method which has shown promise on a wide variety of structures. The technique utilizes small piezoceramic (PZT) patches attached to a structure as self-sensing actuators to both excite the structure with high-frequency …

    vt Repository record for Impedance-Based Structural Health Monitoring of Wind Turbine Blades (opens in a new tab)

  12. Temperature Compensation Improvements for Impedance Based Structural Health Monitoring

    … life and performance of engineering structures. Impedance-Based SHM utilizes the coupled electromechanical behavior of piezoelectric materials to detect adverse changes and material and mechanical failures of structures. Environmental variables such as temperature present a challenge to assessing …

    vt Repository record for Temperature Compensation Improvements for Impedance Based Structural Health Monitoring (opens in a new tab)

  13. Applications of impedance-based fault locating methods in power systems

    … whether by actual field data or simulated data based on field parameters.

    texas Repository record for Applications of impedance-based fault locating methods in power systems (opens in a new tab)

  14. Impedance-Based Wireless Sensor Network for Metal-Protective Coating Evaluation

    … coating usually uses the Electrochemical Impedance Spectroscopy (EIS) method. This paper presents a new impedance-based wireless sensor network for metal-protective coating evaluation. This wireless sensor network consists of two parts: impedance-based wireless sensor nodes and a wireless …

    ndsu Repository record for Impedance-Based Wireless Sensor Network for Metal-Protective Coating Evaluation (opens in a new tab)

  15. Impedance based MEMS sensor for monitoring time sensitive oocyte cryopreservation

    [ACCESS RESTRICTED TO THE UNIVERSITY OF MISSOURI-COLUMBIA AT AUTHOR'S REQUEST.] In recent centuries, women in their 30s and 40s have represented an increasing portion of fertility patients who have had difficulties in fertilization. Those patients' problems are poor oocyte quality and other …

    missouri Repository record for Impedance based MEMS sensor for monitoring time sensitive oocyte cryopreservation (opens in a new tab)

  16. ANALYSIS AND IMPEDANCE-BASED DETECTION OF ELECTROMAGNETIC COIL INSULATION DEGRADATION

    … of the system in which the coil is used. Impedance monitoring of coils has emerged as a promising approach for non-invasive, in-situ insulation health assessments of electromagnetic coils. Yet, little was understood about the relationship between coil impedance and traditional insulation …

    maryland Repository record for ANALYSIS AND IMPEDANCE-BASED DETECTION OF ELECTROMAGNETIC COIL INSULATION DEGRADATION (opens in a new tab)

  17. Impedance-Based Detection of Tissue Using a Multi-Electrode Device

    … from biopsies that turn out to be benign. Thus, impedance-based detection using a multi-electrode device was investigated as a noninvasive technique to diagnose melanoma skin cancer. The multi-electrode device was designed with 8 equally spaced Ag/AgCl electrodes surrounding one central electrode …

    calpoly Repository record for Impedance-Based Detection of Tissue Using a Multi-Electrode Device (opens in a new tab)

  18. Development of the Impedance-based Arc-Flash Determination Device (IADD)

    This thesis entitled, 'Development of the Impedance based Arc-Fault Determination Device (IADD)' details the development of a testing device that, when attached to an electrical node on the power system and through observations on voltage, current and phase shift with a step load change, determines …

    clemson Repository record for Development of the Impedance-based Arc-Flash Determination Device (IADD) (opens in a new tab)

  19. Impedance-based moisture content sensor assessment for gas-phase biofilters

    A woodchips-based gas-phase biofilter is capable of mitigating airborne ammonia efficiently. The moisture content (MC) of the biofilter media is important to determine ammonia mitigation and nitrous oxide generation. It is critical to monitor real-time moisture content of the biofilter media for …

    uiuc Repository record for Impedance-based moisture content sensor assessment for gas-phase biofilters (opens in a new tab)

Page 1 of 13