Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 69 for “"Impedimetric"”.
-
Integrated low-power interfaces for impedimetric chemical sensors
This thesis presents two interface circuits for impedimetric chemical sensors: one for passive chemical sensors and the other for ChemFETs. Both interfaces were fabricated in 0.35μm BiCMOS technology and provide the same output data rate of 1Hz. The interface for passive impedimetric sensors is …
-
Impedimetric Sensor System for Edible Oil Quality Assessment
The repeated usage of frying oil is hazardous due to the degradation caused by chemical reactions, which happen while heating. The total polar compounds and the free fatty acids are the main two chemical parameters affected by frying. These parameters increase significantly with the use of oil for …
-
Cyclodextrin Impedimetric Biosensors for the Detection of Hydrophobic Metabolites
… this project is to develop a cyclodextrin (CD) impedimetric tongue that can provide early warning of sepsis by continuous monitoring the course of the disease and real-time profiling of urine samples in hospitalized patients. The cyclodextrin impedimetric tongue will also enable healthcare …
-
Developing an impedimetric glucose sensor using multi-layer molecularly imprinting technique
A sensitive and cost-effective measurement of glucose has always been a priority in clinical and quality control arena. In this article, molecularly imprinted and non-imprinted polymer (MIP & NIP) based on conducting polymers and functionalized composites was suggested to achieve repeatable and …
-
Design, Fabrication and Performance Evaluation of an Impedimetric Urea Biosensor System
… rate than PEGylated and thus provided a faster impedimetric response to various molar concentrations of urea. Long-term stability (one month) of the PEGylated-urease hydrogel was favorable. A dedicated three-element array impedimetric instrument, the 3EIC BioAnalyzer was designed and produced. A …
-
An Impedimetric Aptasensing System for the Rapid Detection of Salmonella Typhimurium
… health. The goal of this study was to develop an impedimetric aptasensor for the rapid detection of Salmonella Typhimurium using a system setup from our previous study. In this study, gold interdigitated array microelectrodes were immobilized with NH2-Salmonella Typhimurium aptamers to capture S. …
-
Affimer-based impedimetric biosensors: the new analytical platform for biorecognition applications
… The main objective of this thesis is to develop impedimetric biosensors using Affimers, novel non-antibody binding proteins, as bioreceptors to detect a small molecule target, dichlorodiphenyltrichloroethane (DDT), and a protein biomarker, fibroblast growth factor receptor 3 (FGFR3). Initial work …
-
Simultaneous Multiplexer-Free AC-Measurement for Two-Dimensional Impedimetric Sensor Matrices
… reduce the cross-talk effects in two-dimensional impedimetric sensor matrices, where both the real part and imaginary part of the impedance need to be accurately measured. A multi-row excitation strategy using AC signals having different frequencies is proposed to avoid DC deviations due to the …
-
Development of Low-Cost Impedimetric Biosensors for Clinical Diagnostics and Water Testing
… foundation, the group has successfully designed impedimetric biosensors that respond via a change in resistance when foreign pathogens are introduced. Proof of concept testing has confirmed the technology's ability to detect for the presence of pathogens at clinically relevant concentrations. In …
-
Development of an impedimetric biosensor using a non-antibody based biological recognition molecule
… for the development of an electrochemical impedimetric biosensor. Cloning of the Adhiron binders in pET-11(a) expression vector, optimisation of expression and purification of the binders, was carried out and the binders were obtained in soluble form. Adhiron myc binder 2, which showed the …
-
Development of Facile Microfabrication Technologies for the Fabrication and Characterization of Multimodal Impedimetric, Plasmonic, and Electrophysiological Biosensors
The objective of this dissertation was to develop novel methods of patterning inorganic and organic materials, develop biocompatibility evaluations, and subsequently apply these methods toward developing biosensors and lab-on-a-chip devices, such as Interdigitated Electrodes (IDEs) and …
-
Development of impedimetric biosensors based on phage-modified microarrays, for the direct and spedific detection of bacteria
… these microarrays for the direct and specific impedimetric detection of bacteria has been demonstrated.
-
Development of a MEMS-Based Resonant and Impedimetric Multivariate Sensor for the Speciation And Quantification of Volatile Organic Compounds
… sensing film to provide both gravimetric and impedimetric analysis of gaseous analytes in the environment. Multivariate analysis techniques including dispersion analysis and machine learning methods were applied to both the steady-state and transient sensor response data enabling both …
-
Development of a Non-Faradaic Impedimetric Biosensor Based on Reduced Graphene Oxide for the Detection of Brain-Derived Neurotrophic Factor (BDNF)
Neurological disorders affect millions of people worldwide. In the case of Alzheimer’s disease (AD), the rising number of cases significantly increases global healthcare costs. Therefore, early detection of biomarkers at the onset of the disease is essential for early diagnosis. This study presents …
-
Studies on the rapid detection of the food-borne pathogen Listeria monocytogenes
In this work a selective impedimetric assay was developed with the aim of reducing the presumptive detection time of the pathogenic foodborne microbe Listeria monocytogenes. For rapid detection of the target organism, the physical assay conditions and the nutritional composition of the impedimetric …
-
Wechselstromuntersuchung an Rohmilch mit dem Ziel der Zellzahlbestimmung
… between the count of the milk cells and the impedimetric quanities of the milk was examined systematically in a new measure cell with alternating current. The measurements were executed isotherm with different temperatures over a wide frequency area (10 Hz -13 MHz) and the results were …
-
A Non-Enzymatic Continuous Glucose Monitoring System Using Electrochemical Impedance Spectroscopy
… the effects of glucose concentration on impedimetric response, and a real time measuring trial of glucose sensing at low, medium, and high concentration levels over a period of fixed frequency and voltage excitation. The resultant data from each of the trials is modeled using electrical …
-
Development of biosensors using novel bioreceptors; Investigation and optimisation of fundamental parameters at the nanoscale
… which may help accelerate the development of impedimetric immunosensors and enhance their adoption in diagnostic and field applications. Initial work in this thesis has focussed on the development of a biosensor which could be regenerated, permitting repeated use. This work was done using a …
-
Berlyno mėlynojo pagrindu suformuotų biologinių jutiklių taikymas kenksmingų jonų nustatymui /
… 7 buffer solution and tap water as well as using impedimetric measure in pH 7 buffer solution. The experiment using amperometry method shows that the Hg2+ concentration can be successfully determined in the interval from 1000 µmol/L to 3000 µmol/L when measurements were performed in the pH 7 …
-
Synergy between droplet microfluidics and biosensorics.
… Cefotaxime. The system performed up to 4-hour impedimetric monitoring of once generated array, thus providing high statistical validity of the measurement, and ability to monitor the changes within the droplets content for several hours, basically allowing to obtain 150 separate droplet …
Page 1 of 4