Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 19 of 19 for “"Implant Alignment"”

  1. Computational Techniques to Predict Orthopaedic Implant Alignment and Fit in Bone

    … and reliably predict a priori what the final malalignment will be or even what implant size should be used for a certain patient, the overarching goal of all arthroplastic procedures is to ensure that an appropriate match exists between the native and prosthetic axes of the articulation. To …

    uwo Repository record for Computational Techniques to Predict Orthopaedic Implant Alignment and Fit in Bone (opens in a new tab)

  2. Combined Experimental and Statistical Model to Understand the Role of Anatomical and Implant Alignment Variables in Guiding Knee Joint Motion

    … such as patient anatomy, joint loading and implant alignments are all variable in nature. Improvement in the design of orthopedic implants requires a good understanding of the roles that anatomy and implant alignment plays in guiding joint motion. The proposed research focuses on describing …

    ku Repository record for Combined Experimental and Statistical Model to Understand the Role of Anatomical and Implant Alignment Variables in Guiding Knee Joint Motion (opens in a new tab)

  3. An Accuracy and Precision Analysis of the VELYS™ Robotic Assisted Solution for Total Knee Arthroplasty

    … replaced with a combination of metal and polymer implants that recreates the joint line to restore function and quality of life. Implant alignment is important in the success of a TKA. Modern day conventional instrumentation can be cumbersome in the operating room and can be inaccurate when …

    denver Repository record for An Accuracy and Precision Analysis of the VELYS™ Robotic Assisted Solution for Total Knee Arthroplasty (opens in a new tab)

  4. Investigating the biomechanical outcomes of a robotic-assisted versus conventional unicompartmental knee arthroplasty

    … been failures associated with UKA caused by misalignment of the implants. To improve the implant alignment a robotic guidance system called the RIO Robotic Arm has been developed by MAKO Surgical Corp (Ft. Lauderdale, FL). This robotic system provides real-time tactile feedback to the surgeon …

    strathclyde Repository record for Investigating the biomechanical outcomes of a robotic-assisted versus conventional unicompartmental knee arthroplasty (opens in a new tab)

  5. Explicit Finite Element Modeling of Knee Mechanics During Simulated Dynamic Activities

    … can affect patient satisfaction and long-term implant performance. The work presented in this dissertation is a demonstration of how anatomic three-dimensional (3D) computational knee models can be an effective alternative for investigating knee mechanics when compared to the cost and time …

    denver Repository record for Explicit Finite Element Modeling of Knee Mechanics During Simulated Dynamic Activities (opens in a new tab)

  6. IMAGE-GUIDED SURFACE-BASED REGISTRATION OF THE ELBOW

    … option for patients with disorders of the elbow. Implant malpositioning, as a result of an incorrect reproduction of the elbow’s flexion-extension axis, is an important cause of implant- related complications. Current surgical approaches introduce axis estimation errors that can vary …

    uwo Repository record for IMAGE-GUIDED SURFACE-BASED REGISTRATION OF THE ELBOW (opens in a new tab)

  7. DESIGN, VALIDATION AND NAVIGATION OF ANATOMIC POPULATION- BASED AND PATIENT-SPECIFIC RADIAL HEAD IMPLANTS

    … are commonly performed; however, most available implants do not accurately replicate the complex native anatomy. This work examines the creation and surgical implantation of an anatomic implant system. Radial head morphology was parameterized using ellipse fitting to allow reverse engineering of …

    uwo Repository record for DESIGN, VALIDATION AND NAVIGATION OF ANATOMIC POPULATION- BASED AND PATIENT-SPECIFIC RADIAL HEAD IMPLANTS (opens in a new tab)

  8. Influence Of Implant Angulation On The Fracture Resistance Of Zirconia Abutments

    Zirconia-based implant abutments are widely used in prosthetic dentistry. Custom made abutments are utilized to correct for non-ideal implant positions and can successfully accommodate the morphologic requirements of the overlying crown. It was hypothesized that there will be difference in fracture …

    uab Repository record for Influence Of Implant Angulation On The Fracture Resistance Of Zirconia Abutments (opens in a new tab)

  9. Finite element analysis of total ankle replacement

    … models of the TAR to explore the effects of implant geometry, bone quality and implant positioning on its performance. Finite element models were created using CT images of five cadaveric ankle scans. In initial modelling, five positions in the gait cycle were used to quantify the affect of …

    whiterose Repository record for Finite element analysis of total ankle replacement (opens in a new tab)

  10. Finite Element Modeling of Patient-Specific Total Shoulder Arthroplasty

    … the effects of variation of certain patient and implant alignment parameters that may influence long-term outcomes of these surgical procedures, including kinematics, joint loads and contact mechanics. Computational models of six TSA subjects, three aTSA and three rTSA, were created using …

    denver Repository record for Finite Element Modeling of Patient-Specific Total Shoulder Arthroplasty (opens in a new tab)

  11. The Effect of Central Screw and Post Vault Containment on Reverse Total Shoulder Arthroplasty (RSTA) Baseplate Stability

    … into 6 study groups, each having different implant configurations with varying baseplate lateralization and central screws or posts. Each specimen was subjected to cyclic shear loading and failure testing on an Instron to determine implant micromotion and load values. After testing, ANOVA …

    clemson Repository record for The Effect of Central Screw and Post Vault Containment on Reverse Total Shoulder Arthroplasty (RSTA) Baseplate Stability (opens in a new tab)

  12. Implementation and verification of a flexible optical tracker

    … conventional surgical techniques with regards to implant alignment and outlier reduction, computer navigation systems have not faced widespread adoption in surgical operating rooms. We believe that one of the reasons for the low uptake stems from the bulky design of the optical tracker assemblies. …

    ubc Repository record for Implementation and verification of a flexible optical tracker (opens in a new tab)

  13. In Vitro Investigations of Conventional vs. Robotic-Assisted Total Knee Arthroplasty

    … and sizing jigs determine cut positioning and implant orientation. However, persistent patient dissatisfaction and revision rates highlight limitations with conventional TKA (cTKA) methods. Robotic-assisted TKA (rTKA) systems have been developed to reduce surgical errors, increase the accuracy …

    uwo Repository record for In Vitro Investigations of Conventional vs. Robotic-Assisted Total Knee Arthroplasty (opens in a new tab)

  14. AN OPTOELECTRONIC MOTION CAPTURE PROTOCOL FOR IN CLINIC ORTHOPAEDIC GAIT ANALYSIS

    … Florida) Robot has significantly improved PKA implant alignment by providing real-time feedback during surgery and improving three-dimensional implant placement accuracy. To assess kinematic differences between robotic assisted PKA and manual technique TKA, a 14-camera optoelectronic motion …

    mcmaster Repository record for AN OPTOELECTRONIC MOTION CAPTURE PROTOCOL FOR IN CLINIC ORTHOPAEDIC GAIT ANALYSIS (opens in a new tab)

  15. Development of a Computational Approach to Assess Hip Fracture and Repair: Considerations of Intersubject and Surgical Alignment Variability

    … to evaluate fracture repair. Natural and implanted finite element models were used to predict fracture patterns and evaluate bone-implant load share in subjects with varying geometry and bone quality. A model validation study demonstrated the capability of XFEM in generating unique …

    denver Repository record for Development of a Computational Approach to Assess Hip Fracture and Repair: Considerations of Intersubject and Surgical Alignment Variability (opens in a new tab)

  16. Neue intraoperative Techniken zur Verbesserung des Outcomes nach Kniegelenktotalendoprothetik

    Die Implantation einer Kniegelenktotalendoprothese ist eine erfolgreiche und kosteneffiziente Methode zur Behandlung der Arthrose des Kniegelenks. Die Implantatüberlebensraten haben sich stetig verbessert. Jedoch sind nach wie vor nicht alle Patienten mit dem Ergebnis des Eingriffs zufrieden. Die …

    fu-berlin Repository record for Neue intraoperative Techniken zur Verbesserung des Outcomes nach Kniegelenktotalendoprothetik (opens in a new tab)

  17. Optimizing Femoral Head Preparation in Hip Resurfacing Arthroplasty

    … of hip joint replacement. The acetabular cup is implanted in much the same fashion as an uncemented total hip arthroplasty, however, implantation of the femoral component is unique to hip resurfacing, presenting both distinct benefits and limitations. Hip resurfacing spares much of the proximal …

    toronto-retro Repository record for Optimizing Femoral Head Preparation in Hip Resurfacing Arthroplasty (opens in a new tab)

  18. Variability in semi-automatic segmentation from CT images : implications for knee joint modelling

    … knee replacement outcomes, primarily due to implant malalignment. Virtual 3D knee models, generated from CT and MRI scans, play a critical role in improving implant alignment before surgery. These models enable preoperative planning by allowing surgeons to virtually model the patient's knee …

    strathclyde Repository record for Variability in semi-automatic segmentation from CT images : implications for knee joint modelling (opens in a new tab)