Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 61 for “"Implant Designs"”.
-
Novel Implant Designs In Magnetic Drug Targeting
… forces, have led researchers to study the use of implants to increase magnetic forces and the collection of MDCPs. This method is termed implant assisted (IA) - MDT, which exploits basic principles of high gradient magnetic separation to improve local drug retention. The work herein will address …
-
Bone conduction devices. Implant designs and long-term use
Contains fulltext : 151700.pdf (Publisher’s version ) (Open Access)
-
Biomechanical Outcomes of Distinct TKA Surgical Alignments and Implant Designs
… alignment methods with an overall goal of implant longevity to ones that are more personalized to better replicate individual native knee kinematics. Personalizing TKA knee kinematics to better replicate a patient’s native knee kinematics has evolved in response to a reported 20% …
-
Evaluation of two different implant designs: preliminary results of a randomized controlled equivalence trial
… to test whether or not the modified design of an implant with microthreads at the implant collar has an equivalent effect on marginal bone loss (MBL) when compared to the control implant without microthreads. The respective study group consisted of 40 patients with a mean age of 58.2±15.1 years, …
-
ROBOT-ASSISTED ORTHOPAEDIC SURGERY INTERVENTIONS WITH BIOMECHANICAL GUIDED PLANNING AND ANALYSIS OF NOVEL IMPLANT DESIGNS
… addition, orthopaedic interventions commonly use implants, such as screws, plates, and prostheses, and bone filling materials like bone cement, bone grafts, and bioresorbable bone substitutes, to treat a variety of bone defects and condi- tions. This dissertation presents the development of a …
-
CLINICAL EFFECTS OF CURRENT DENTAL IMPLANT DESIGNS ON BONE LOSS AND THEIR APPLICATIONS FOR NEXT-GENERATION OSSEOINTEGRATION USING 3D PRINTED TITANIUM
… we attempted to answer the following: 1) Does implant design affect bone level and osseointegration? 2) Can a standardized model for differently porous dental implant be established? A systematic review and meta-analysis (SR/MAs) was performed to determine clinically used implants involving …
-
Inverse analysis of dental implant systems using finite element method
Dental implant designs and implant-bone interface properties are the main factors governing the long-term success of implants. However, influence of variety of these factors has yet to be fully elucidated. Motivated by its application in stress analysis, finite element analysis (FEA) is used to …
-
Development and Implementation of a Forward Solution Hip Mathematical Model to Determine In Vivo Mechanics and Predict Hip Separation
… issue revolves around developing progressive new implant designs, establishing the least destructive surgical methods, and determining and executing ideal intraoperative component alignments. However, ethical issues and extravagant expenses prevent surgeons and implant companies from experimenting …
-
Theoretical models of information transmission at the electro-neural interface of cochlear implants
… to address unsolved questions in cochlear implant research, i.e., i) what is the optimal number of electrodes for achieving enhanced hearing, ii) whether new designs of electrode arrays may exploit more electrodes to enhance performance, and iii) whether the performance of cochlear implants …
-
Evaluation and Biomechanical Analysis of Equine Prosthetics
… of veterinary prosthetics. The objective of the implant study was to validate the biomechanical feasibility of two basic prosthetic implants for horses. The objective of the foot study was to virtually design a simple, inexpensive and accessible prosthetic foot for amputee horses, as well as …
-
Novel insights in cruciate-retaining total knee arthroplasty
… on posterior cruciate ligament (PCL)-retaining designs. The findings show that insert geometry has minimal impact on knee stability. Long-term results indicate that fixed-bearing (FB) inserts have higher survival rates than mobile-bearing (MB) inserts. Additionally, 26% of patients develop …
-
Total Knee Replacements: Component Design, Pain Prevention and Research Techniques
… procedure in which the knee is resurfaced with implants to relieve pain. This thesis presents computed tomography and radiography methods to determine the relative position (kinematics) for the patellofemoral and tibiofemoral joints in vivo for a full range of motion, as well as parameters …
-
On the fly: Host determinants of RNA virus evolution
… in corrective osteotomy, while some new knee implant designs require further improvement. Other innovations showed promising results, including a new knee implant design with good early stability and improved function. In addition, artificial intelligence was shown to be capable of detecting …
-
Evaluating device-related innovations and advanced diagnostics in knee osteoarthritis: from joint preservation to revision surgery
… in corrective osteotomy, while some new knee implant designs require further improvement. Other innovations showed promising results, including a new knee implant design with good early stability and improved function. In addition, artificial intelligence was shown to be capable of detecting …
-
Flexible Screw Design for Bone Implant Application
… to create a moveable section in a bone screw implant. Designs that met the specifications and were promising from the manufacturing point of view were tested using finite element analysis. Some designs were prototyped and one of them was tested using a cadaver wrist. Every design concept …
-
Imaging-based customization of lattice structures for biomedical applications
… Commercially available joint reconstruction implants have undergone great improvement during the past decades. Nevertheless, existing solutions using available implant designs and materials have limitations that lead to potential failure, particularly with young active patients. Bone cement …
-
A Study of Vagus Nerve Stimulation Issues and Techniques for Hemodynamic Control
… care practitioner in mind, it appears that both implanted and non-invasive VNS approaches will have their own unique roles in treating cardiovascular disease. Under that scenario, new and more comfortable VNS implant designs and protocols can benefit from non-invasive VNS (NI-VNS) device and …
-
Research and development of silicon strip detectors in CMOS- and 3D-technology, and construction and characterisation of detector modules for the Phase-II upgrade of the ATLAS experiments
… enabling a detailed study of how different implant designs influence electric field formation. A comparative analysis of TCAD simulations and laboratory measurements is presented. In addition, further laboratory characterisation of CMOS strip sensors is included. The second part of this …
-
Side-to-Side Comparison of Total Shoulder Arthroplasty and Intact Function in Individuals
… is to determine if patients with one of two TSA implant designs on one side achieve the same range of motion as their intact side, and if so to find if they compensate using increased scapula rotation over normal humeral motion. Six TSA subjects performed for each shoulder abduction, forward …
-
Finite Element Analysis of Total Knee Arthroplasty
… in 1968, the TKA’s surgical process and implant designs have continuously been improved to increase survivability. However, the need for a revision TKA – due to aseptic loosening – continues to be a problematic aspect of the procedure. Stress shielding induced by different design …
Page 1 of 4